메뉴 건너뛰기




Volumn 46, Issue 10, 2009, Pages 1291-1297

Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: A prospective observational study

Author keywords

Cardiac output; Haemodynamic monitoring; Non invasive; Pulmonary artery catheterisation

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL COMPETENCE; CLINICAL NURSING RESEARCH; COMPARATIVE STUDY; EDUCATION; EPIDEMIOLOGY; HEART OUTPUT; HUMAN; INSTRUMENTATION; INTENSIVE CARE; METHODOLOGY; MIDDLE AGED; MONITORING; NURSE ATTITUDE; NURSING; NURSING ASSESSMENT; NURSING STAFF; PILOT STUDY; PROFESSIONAL PRACTICE; PROSPECTIVE STUDY; STANDARD; SWAN GANZ CATHETER; THERMODILUTION; VALIDATION STUDY;

EID: 67651211722     PISSN: 00207489     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijnurstu.2009.03.013     Document Type: Article
Times cited : (23)

References (29)
  • 1
    • 67651248646 scopus 로고    scopus 로고
    • Angiography and Intervention Lippincott/Williams & Wilkins, Philadelphia pp. 163-168
    • Baim D. Cardiac Catheterisation (2006), Angiography and Intervention Lippincott/Williams & Wilkins, Philadelphia pp. 163-168
    • (2006) Cardiac Catheterisation
    • Baim, D.1
  • 2
    • 0036373045 scopus 로고    scopus 로고
    • Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution
    • Balik M., Pachl J., and Hendl J. Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution. Intensive Care Med. 28 8 (2002) 1117-1121
    • (2002) Intensive Care Med. , vol.28 , Issue.8 , pp. 1117-1121
    • Balik, M.1    Pachl, J.2    Hendl, J.3
  • 3
    • 0037865718 scopus 로고    scopus 로고
    • Cardiovascular monitoring tools: use and misuse
    • Bellomo R., and Uchino S. Cardiovascular monitoring tools: use and misuse. Curr. Opin. Crit. Care 9 3 (2003) 225-229
    • (2003) Curr. Opin. Crit. Care , vol.9 , Issue.3 , pp. 225-229
    • Bellomo, R.1    Uchino, S.2
  • 6
    • 34347375489 scopus 로고    scopus 로고
    • Agreement between methods of measurement with multiple observations per individual
    • Bland J.M., and Altman D.G. Agreement between methods of measurement with multiple observations per individual. J. Biopharm. Stat. 17 4 (2007) 571-582
    • (2007) J. Biopharm. Stat. , vol.17 , Issue.4 , pp. 571-582
    • Bland, J.M.1    Altman, D.G.2
  • 7
    • 33646901597 scopus 로고    scopus 로고
    • Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery
    • Chand R., Mehta Y., and Trehan N. Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery. J. Cardiothorac. Vasc. Anesth. 20 3 (2006) 315-319
    • (2006) J. Cardiothorac. Vasc. Anesth. , vol.20 , Issue.3 , pp. 315-319
    • Chand, R.1    Mehta, Y.2    Trehan, N.3
  • 9
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley L.A., and Critchley J.A. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J. Clin. Monit. Comput. 15 2 (1999) 85-91
    • (1999) J. Clin. Monit. Comput. , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 10
    • 14544292461 scopus 로고    scopus 로고
    • Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs
    • (table of contents)
    • Critchley L.A., Peng Z.Y., Fok B.S., Lee A., and Phillips R.A. Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs. Anesth. Analg. 100 3 (2005) 748-753 (table of contents)
    • (2005) Anesth. Analg. , vol.100 , Issue.3 , pp. 748-753
    • Critchley, L.A.1    Peng, Z.Y.2    Fok, B.S.3    Lee, A.4    Phillips, R.A.5
  • 11
    • 22644432668 scopus 로고    scopus 로고
    • Emergency physicians can reliably assess emergency department patient cardiac output using the USCOM continuous wave Doppler cardiac output monitor
    • Dey I., and Sprivulis P. Emergency physicians can reliably assess emergency department patient cardiac output using the USCOM continuous wave Doppler cardiac output monitor. Emerg. Med. Aust. 17 3 (2005) 193-199
    • (2005) Emerg. Med. Aust. , vol.17 , Issue.3 , pp. 193-199
    • Dey, I.1    Sprivulis, P.2
  • 13
    • 0021275040 scopus 로고
    • Clinical evaluation compared to pulmonary artery catheterization in the hemodynamic assessment of critically ill patients
    • Eisenberg P.R., Jaffe A.S., and Schuster D.P. Clinical evaluation compared to pulmonary artery catheterization in the hemodynamic assessment of critically ill patients. Crit. Care Med. 12 7 (1984) 549-553
    • (1984) Crit. Care Med. , vol.12 , Issue.7 , pp. 549-553
    • Eisenberg, P.R.1    Jaffe, A.S.2    Schuster, D.P.3
  • 14
    • 0026573445 scopus 로고
    • Inaccuracy of cardiac output by thermodilution during acute tricuspid regurgitation
    • Heerdt P.M., Pond C.G., Blessios G.A., and Rosenbloom M. Inaccuracy of cardiac output by thermodilution during acute tricuspid regurgitation. Ann. Thorac. Surg. 53 4 (1992) 706-708
    • (1992) Ann. Thorac. Surg. , vol.53 , Issue.4 , pp. 706-708
    • Heerdt, P.M.1    Pond, C.G.2    Blessios, G.A.3    Rosenbloom, M.4
  • 15
    • 0027974196 scopus 로고
    • Assessment of critical care nurses' knowledge of the pulmonary artery catheter. The Pulmonary Artery Catheter Study Group
    • Iberti T.J., Daily E.K., Leibowitz A.B., Schecter C.B., Fischer E.P., and Silverstein J.H. Assessment of critical care nurses' knowledge of the pulmonary artery catheter. The Pulmonary Artery Catheter Study Group. Crit. Care Med. 22 10 (1994) 1674-1678
    • (1994) Crit. Care Med. , vol.22 , Issue.10 , pp. 1674-1678
    • Iberti, T.J.1    Daily, E.K.2    Leibowitz, A.B.3    Schecter, C.B.4    Fischer, E.P.5    Silverstein, J.H.6
  • 16
    • 0025685462 scopus 로고
    • A multicenter study of physicians' knowledge of the pulmonary artery catheter. Pulmonary Artery Catheter Study Group
    • Iberti T.J., Fischer E.P., Leibowitz A.B., Panacek E.A., Silverstein J.H., and Albertson T.E. A multicenter study of physicians' knowledge of the pulmonary artery catheter. Pulmonary Artery Catheter Study Group. JAMA 264 22 (1990) 2928-2932
    • (1990) JAMA , vol.264 , Issue.22 , pp. 2928-2932
    • Iberti, T.J.1    Fischer, E.P.2    Leibowitz, A.B.3    Panacek, E.A.4    Silverstein, J.H.5    Albertson, T.E.6
  • 17
    • 4444256157 scopus 로고    scopus 로고
    • Survey of intensive care nurses' knowledge relating to the pulmonary artery catheter
    • Johnston I.G., Jane R., Fraser J.F., Kruger P., and Hickling K. Survey of intensive care nurses' knowledge relating to the pulmonary artery catheter. Anaesth. Intensive Care 32 4 (2004) 564-568
    • (2004) Anaesth. Intensive Care , vol.32 , Issue.4 , pp. 564-568
    • Johnston, I.G.1    Jane, R.2    Fraser, J.F.3    Kruger, P.4    Hickling, K.5
  • 19
    • 25144520471 scopus 로고    scopus 로고
    • Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery
    • Knobloch K., Lichtenberg A., Winterhalter M., Rossner D., Pichlmaier M., and Phillips R. Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery. Ann. Thorac. Surg. 80 4 (2005) 1479-1483
    • (2005) Ann. Thorac. Surg. , vol.80 , Issue.4 , pp. 1479-1483
    • Knobloch, K.1    Lichtenberg, A.2    Winterhalter, M.3    Rossner, D.4    Pichlmaier, M.5    Phillips, R.6
  • 21
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin L.I. A concordance correlation coefficient to evaluate reproducibility. Biometrics 45 1 (1989) 255-268
    • (1989) Biometrics , vol.45 , Issue.1 , pp. 255-268
    • Lin, L.I.1
  • 22
    • 33750623297 scopus 로고    scopus 로고
    • Interrater reliability of cardiac output measurements by transcutaneous Doppler ultrasound: implications for noninvasive hemodynamic monitoring in the ED
    • Nguyen H.B., Losey T., Rasmussen J., Oliver R., Guptill M., Wittlake W.A., and Corbett S.W. Interrater reliability of cardiac output measurements by transcutaneous Doppler ultrasound: implications for noninvasive hemodynamic monitoring in the ED. Am. J. Emerg. Med. 24 7 (2006) 828-835
    • (2006) Am. J. Emerg. Med. , vol.24 , Issue.7 , pp. 828-835
    • Nguyen, H.B.1    Losey, T.2    Rasmussen, J.3    Oliver, R.4    Guptill, M.5    Wittlake, W.A.6    Corbett, S.W.7
  • 24
    • 0027412923 scopus 로고
    • Indicator amount, temperature, and intrinsic cardiac output affect thermodilution cardiac output accuracy and reproducibility
    • Renner L.E., Morton M.J., and Sakuma G.Y. Indicator amount, temperature, and intrinsic cardiac output affect thermodilution cardiac output accuracy and reproducibility. Crit. Care Med. 21 4 (1993) 586-597
    • (1993) Crit. Care Med. , vol.21 , Issue.4 , pp. 586-597
    • Renner, L.E.1    Morton, M.J.2    Sakuma, G.Y.3
  • 27
    • 26044478155 scopus 로고    scopus 로고
    • Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials
    • Shah M.R., Hasselblad V., Stevenson L.W., Binanay C., O'Connor C.M., Sopko G., and Califf R.M. Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials. JAMA 294 13 (2005) 1664-1670
    • (2005) JAMA , vol.294 , Issue.13 , pp. 1664-1670
    • Shah, M.R.1    Hasselblad, V.2    Stevenson, L.W.3    Binanay, C.4    O'Connor, C.M.5    Sopko, G.6    Califf, R.M.7
  • 28
    • 14844354490 scopus 로고    scopus 로고
    • Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit
    • Tan H.L., Pinder M., Parsons R., Roberts B., and van Heerden P.V. Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. Br. J. Anaesth. 94 3 (2005) 287-291
    • (2005) Br. J. Anaesth. , vol.94 , Issue.3 , pp. 287-291
    • Tan, H.L.1    Pinder, M.2    Parsons, R.3    Roberts, B.4    van Heerden, P.V.5
  • 29
    • 0022589340 scopus 로고
    • Comparison between ultrasonic and thermodilution cardiac output measurements in intensive care patients
    • Vandenbogaerde J.F., Scheldewaert R.G., Rijckaert D.L., Clement D.L., and Colardyn F.A. Comparison between ultrasonic and thermodilution cardiac output measurements in intensive care patients. Crit. Care Med. 14 4 (1986) 294-297
    • (1986) Crit. Care Med. , vol.14 , Issue.4 , pp. 294-297
    • Vandenbogaerde, J.F.1    Scheldewaert, R.G.2    Rijckaert, D.L.3    Clement, D.L.4    Colardyn, F.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.