-
2
-
-
0035380085
-
Dampness in buildings and health - Nordic interdisciplinary review of the scientific evidence on associations between expo-sure to "dampness" trade; In buildings and health effects (NORDDAMP)
-
Bornehag, C.-G., Blomquist, G., Gyntelberg, F., Jarvholm, B., Malmberg, P., Nordvall, L., et al. (2001). Dampness in Buildings and Health - Nordic Interdisciplinary Review of the Scientific Evidence on Associations between Expo-sure to "Dampness" in Buildings and Health Effects (NORDDAMP), Indoor Air, 11: 72-86.
-
(2001)
Indoor Air
, vol.11
, pp. 72-86
-
-
Bornehag, C.-G.1
Blomquist, G.2
Gyntelberg, F.3
Jarvholm, B.4
Malmberg, P.5
Nordvall, L.6
-
3
-
-
0003009404
-
Impact of temperature and humidity on the perception of indoor air quality
-
Fang, L., Clausen, G. and Fanger, P. (1998). Impact of Temperature and Humidity on the Perception of Indoor Air Quality, Indoor Air, 8: 80-90.
-
(1998)
Indoor Air
, vol.8
, pp. 80-90
-
-
Fang, L.1
Clausen, G.2
Fanger, P.3
-
4
-
-
0004037722
-
-
Copenhagen : Danish Tecahnical Press
-
Fanger, P. (1970). Thermal Comfort, Copenhagen: Danish Tecahnical Press.
-
(1970)
Thermal Comfort
-
-
Fanger, P.1
-
5
-
-
0038354119
-
-
PhD Thesis, Department of Structural Engineering and Materials Lyngby, Technical University of Denmark
-
Padfield, T. (1998). The Role of Absorbent Building Materials in Moderating Changes of Relative Humidity, PhD Thesis, Department of Structural Engineering and Materials, Lyngby, Technical University of Denmark, p. 150.
-
(1998)
The Role of Absorbent Building Materials in Moderating Changes of Relative Humidity
, pp. 150
-
-
Padfield, T.1
-
6
-
-
33745395603
-
Test cell measurements of moisture buffer effects
-
Rode, C., Mitamura, T., Schultz, J. and Padfield, T. (2002). Test Cell Measurements of Moisture Buffer Effects, In: 6th Symposium on Building Physics in the Nordic Countries, Trondheim, Norway.
-
6th Symposium on Building Physics in the Nordic Countries
-
-
Rode, C.1
Mitamura, T.2
Schultz, J.3
Padfield, T.4
-
7
-
-
67651207429
-
-
PhD Thesis, Department of Civil Engineering, Faculty of Engineering, University of Porto, Porto.
-
Ramos, N. (2007). The Importance of Hygroscopic Inertia on Buildings Hygrothermal Behaviour (in Portuguese), PhD Thesis, Department of Civil Engineering, Faculty of Engineering, University of Porto, Porto.
-
(2007)
The Importance of Hygroscopic Inertia on Buildings Hygrothermal Behaviour (In Portuguese)
-
-
Ramos, N.1
-
8
-
-
56249138956
-
Evaluation strategy of finishing materials contribution to the hygroscopic inertia of a room Research in Building Physics and Building Engineering
-
Concordia University, Montreal, Canada, 27-31 August
-
Ramos, N. and de Freitas, V.P. (2006). Evaluation Strategy of Finishing Materials Contribution to the Hygroscopic Inertia of a Room. Research in Building Physics and Building Engineering. In: Proceedings of the Third International Building Physics Conference, Concordia University, Montreal, Canada, 27-31 August 2006, pp. 543-548.
-
(2006)
Proceedings of the Third International Building Physics Conference
, pp. 543-548
-
-
Ramos, N.1
De Freitas, V.P.2
-
9
-
-
11244253156
-
-
VTT Research Notes VTT (Ed.) VTT, Espoo, Finland.
-
Simonson, C. (2000). Moisture, Thermal and Ventilation Performance of Tapanila Ecological House, In: VTT (Ed.) VTT Research Notes, VTT, Espoo, Finland.
-
(2000)
Moisture, Thermal and Ventilation Performance of Tapanila Ecological House
-
-
Simonson, C.1
-
10
-
-
0036984380
-
The effect of structures on indoor humidity - Possibility to improve comfort and perceived air quality
-
Simonson, C., Salonvaara, M. and Ojanen, T. (2002). The Effect of Structures on Indoor Humidity - Possibility to Improve Comfort and Perceived Air Quality, Indoor Air, 12: 243-251.
-
(2002)
Indoor Air
, vol.12
, pp. 243-251
-
-
Simonson, C.1
Salonvaara, M.2
Ojanen, T.3
-
11
-
-
0032141975
-
Upper limits for indoor air humidity to avoid uncomfortably humid skin
-
Toftum, J., Jorgensen, A. and Fanger, P. (1998 a). Upper Limits for Indoor Air Humidity to Avoid Uncomfortably Humid Skin, Energ Buildings, 28: 1-13.
-
(1998)
Energ Buildings
, vol.28
, pp. 1-13
-
-
Toftum, J.1
Jorgensen, A.2
Fanger, P.3
-
12
-
-
0032137599
-
Upper limits of air humidity for preventing warm respiratory discomfort
-
PII S0378778897000182
-
Toftum J., Jorgensen, A. and Fanger, P. (1998 b). Upper Limits of Air Humidity for Preventing Warm Respiratory Discomfort, Energ Buildings, 28: 15-23. (Pubitemid 128401549)
-
(1998)
Energy and Buildings
, vol.28
, Issue.1
, pp. 15-23
-
-
Toftum, J.1
Jorgensen, A.S.2
Fanger, P.O.3
-
13
-
-
70349738001
-
Experiment for Synthetic Evaluation of Moisture Buffering Effect in A Room
-
Trondheim, Norway
-
Yoshino, H., Mitamura, T., Hasegawa, K., Matsumoto, S. and Adachi, M. (2005). Experiment for Synthetic Evaluation of Moisture Buffering Effect in a Room, In: IEA Annex 41 Meeting, Trondheim, Norway, pp. 1-6.
-
(2005)
IEA Annex 41 Meeting
, pp. 1-6
-
-
Yoshino, H.1
Mitamura, T.2
Hasegawa, K.3
Matsumoto, S.4
Adachi, M.5
|