메뉴 건너뛰기




Volumn , Issue , 2006, Pages 543-548

Evaluation strategy of finishing materials contribution to the hygroscopic inertia of a room

Author keywords

[No Author keywords available]

Indexed keywords

ATMOSPHERIC HUMIDITY; BUILDINGS; ENGINEERING RESEARCH; TEXTILE FINISHING; TEXTILE PROCESSING;

EID: 56249138956     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (10)

References (14)
  • 3
    • 27844567963 scopus 로고    scopus 로고
    • Full scale testing of indoor humidity and moisture buffering materials
    • Mitamura, T., Rode, C. and Schultz, J. (2001). Full scale testing of indoor humidity and moisture buffering materials. ASHRAE Conference Indoor Air.
    • (2001) ASHRAE Conference Indoor Air
    • Mitamura, T.1    Rode, C.2    Schultz, J.3
  • 4
    • 27844521643 scopus 로고    scopus 로고
    • A Method to Determine the Moisture Buffering Effect of Structures During Diurnal Cycles of Indoor Air Moisture Loads
    • Leuven, Belgium, Swets & Zeitlinger
    • Ojanen, T. and Salonvaara, M. (2003). A Method to Determine the Moisture Buffering Effect of Structures During Diurnal Cycles of Indoor Air Moisture Loads. 2nd International Building Physics Conference, Leuven, Belgium, Swets & Zeitlinger.
    • (2003) 2nd International Building Physics Conference
    • Ojanen, T.1    Salonvaara, M.2
  • 6
    • 56249122554 scopus 로고    scopus 로고
    • Quantifying Time Dependent Moisture Storage and Transport Properties
    • Leuven, Belgium, Swets & Zeitlinger
    • Peukhuri, R. (2003). Quantifying Time Dependent Moisture Storage and Transport Properties. 2nd International Building Physics Conference, Leuven, Belgium, Swets & Zeitlinger.
    • (2003) 2nd International Building Physics Conference
    • Peukhuri, R.1
  • 7
    • 0036467402 scopus 로고    scopus 로고
    • Interzonal air and moisture transport in a test house: Experiment and modelling
    • Plathner, P. and Woloszyn, M. (2002). "Interzonal air and moisture transport in a test house: experiment and modelling". Building and Environment 37: 189-199.
    • (2002) Building and Environment , vol.37 , pp. 189-199
    • Plathner, P.1    Woloszyn, M.2
  • 9
    • 56249143061 scopus 로고    scopus 로고
    • Rode, C., Hansen, K.K., Padfield, T., Time, B., Ojanen, T. and Arfvidsson, J. (2003). Nordtest Workshop on Moisture Buffer Capacity - Summary Report, Technical University of Denmark (DTU): 74.
    • Rode, C., Hansen, K.K., Padfield, T., Time, B., Ojanen, T. and Arfvidsson, J. (2003). Nordtest Workshop on Moisture Buffer Capacity - Summary Report, Technical University of Denmark (DTU): 74.
  • 11
    • 56249091726 scopus 로고    scopus 로고
    • Water vapour permeability and sorption isotherm of coated gypsum board
    • The Icelandic Building Research Institute, Reykjavic, Iceland
    • Roels, S. and Carmeliet, J. (2005). Water vapour permeability and sorption isotherm of coated gypsum board. Proceedings of the 7th symposium on building physics in the Nordic Countries, The Icelandic Building Research Institute, Reykjavic, Iceland.
    • (2005) Proceedings of the 7th symposium on building physics in the Nordic Countries
    • Roels, S.1    Carmeliet, J.2
  • 14
    • 56249087894 scopus 로고    scopus 로고
    • METEONORM. Global Meteorological Database for Solar Energy and Applied Climatology. Version 4.0. Software and Data on CD-ROM. Meteotest, Switzerland.
    • METEONORM. Global Meteorological Database for Solar Energy and Applied Climatology. Version 4.0. Software and Data on CD-ROM. Meteotest, Switzerland.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.