메뉴 건너뛰기




Volumn 23, Issue 6, 2009, Pages 403-407

Optimal internal fixation for femoral neck fractures: Multiple screws or sliding hip screws?

Author keywords

Femoral neck; Hip fractures; Internal fixation

Indexed keywords

AVASCULAR NECROSIS; BIOMECHANICS; BONE SCREW; CANCELLOUS BONE; CLINICAL TRIAL; CONFERENCE PAPER; DEVICE; EVIDENCE BASED MEDICINE; FEMUR HEAD; FEMUR NECK FRACTURE; FRACTURE FIXATION; FRACTURE TREATMENT; HEALTH CARE COST; HIP ARTHROPLASTY; HIP FRACTURE; HUMAN; INTERMETHOD COMPARISON; META ANALYSIS; MORTALITY; OSTEOSYNTHESIS; PRIORITY JOURNAL; QUALITY OF LIFE; REOPERATION; RISK ASSESSMENT; SLIDING HIP SCREW; SURGICAL APPROACH; SURGICAL EQUIPMENT; SYSTEMATIC REVIEW; TREATMENT OUTCOME;

EID: 67651052768     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e318176191f     Document Type: Conference Paper
Times cited : (78)

References (25)
  • 1
    • 0026446492 scopus 로고
    • Hip fractures in the elderly: A worldwide projection
    • Cooper C, Campion G, Melton LJ. Hip fractures in the elderly: a worldwide projection. Osteoporos Int. 1992;2:285-289.
    • (1992) Osteoporos Int , vol.2 , pp. 285-289
    • Cooper, C.1    Campion, G.2    Melton, L.J.3
  • 2
    • 0025321429 scopus 로고
    • The future of hip fractures in the United States. Numbers, costs, and potential effects of postmenopausal estrogen
    • Cummings SR, Rubin SM, Black D. The future of hip fractures in the United States. Numbers, costs, and potential effects of postmenopausal estrogen. Clin Orthop Relat Res. 1990;252:163-166.
    • (1990) Clin Orthop Relat Res , vol.252 , pp. 163-166
    • Cummings, S.R.1    Rubin, S.M.2    Black, D.3
  • 3
    • 8644273915 scopus 로고    scopus 로고
    • An estimate of the worldwide prevalence, mortality and disability associated with hip fracture
    • DOI 10.1007/s00198-004-1627-0
    • Johnell O, Kanis JA. An estimate of theworldwide prevalence, mortality and disability associated with hip fracture. Osteoporos Int. 2004;15:897-902. (Pubitemid 39506456)
    • (2004) Osteoporosis International , vol.15 , Issue.11 , pp. 897-902
    • Johnell, O.1    Kanis, J.A.2
  • 4
    • 0030700667 scopus 로고    scopus 로고
    • Current and projected rates of hip fracture in Canada
    • Papadimitropoulos EA, Coyte, PC, Josse RG, et al. Current and projected rates of hip fracture in Canada. CMAJ. 1997;157:1357-1363.
    • (1997) CMAJ , vol.157 , pp. 1357-1363
    • Papadimitropoulos, E.A.1    Coyte, P.C.2    Josse, R.G.3
  • 7
    • 0033756425 scopus 로고    scopus 로고
    • Internal fixation or arthroplasty for displaced cervical hip fractures in the elderly: A randomized controlled trial of 208 patients
    • Parker MJ, Pryor GA. Internal fixation or arthroplasty for displaced cervical hip fractures in the elderly: a randomized controlled trial of 208 patients. Acta Orthop Scand. 2000;71:440-446.
    • (2000) Acta Orthop Scand , vol.71 , pp. 440-446
    • Parker, M.J.1    Pryor, G.A.2
  • 10
    • 85045417428 scopus 로고    scopus 로고
    • Displaced intracapsular hip fractures in fit, older people: A randomised comparison of reduction and fixation, bipolar hemiarthroplasty and total hip arthroplasty
    • Keating JF, Grant A, Masson M, et al. Displaced intracapsular hip fractures in fit, older people:a randomized comparison of reduction and fixation, bipolar hemiarthroplasty and total hip arthroplasty. Health Technol Assess. 2005;9:1-65. (Pubitemid 41683962)
    • (2005) Health Technology Assessment , vol.9 , Issue.41
    • Keating, J.F.1    Grant, A.2    Masson, M.3    Scott, N.W.4    Forbes, J.F.5
  • 11
    • 0022991934 scopus 로고
    • Improved operations for femoral neck fracture. A radiographic evaluation
    • Johansson A, Stromqvist B, Bauer G, et al. Improved operations for femoral neck fracture. A radiographic evaluation. Acta Orthop Scand. 1986;57:505-509.
    • (1986) Acta Orthop Scand , vol.57 , pp. 505-509
    • Johansson, A.1    Stromqvist, B.2    Bauer, G.3
  • 12
    • 0027273066 scopus 로고
    • Cortical screw support in femoral neck fractures. A radiographic analysis of 87 fractures with a new mensuration technique
    • Lindequist, S. Cortical screw support in femoral neck fractures. A radiographic analysis of 87 fractures with a new mensuration technique. Acta Orthop Scand. 1993;64:289-293.
    • (1993) Acta Orthop Scand , vol.64 , pp. 289-293
    • Lindequist, S.1
  • 13
    • 0023415328 scopus 로고
    • Torsion and bending analysis of internal fixation techniques for femoral neck fractures:the role of implant design and bone density
    • Swiontkowski MF, Harrington RM, Keller TS, et al. Torsion and bending analysis of internal fixation techniques for femoral neck fractures:the role of implant design and bone density. J Orthop Res. 1987;5:433-444.
    • (1987) J Orthop Res , vol.5 , pp. 433-444
    • Swiontkowski, M.F.1    Harrington, R.M.2    Keller, T.S.3
  • 14
    • 67651049096 scopus 로고    scopus 로고
    • Treatment of unstable femoral neck fractures: is the dynamic hip screw a superior alternative to 3 cannulated screws? Presented at: (Poster 55); Hollywood, FL
    • Linke B, Schwieger K, Bursic D, et al. Treatment of unstable femoral neck fractures: is the dynamic hip screw a superior alternative to 3 cannulated screws? Presented at: Orthopaedic Trauma Association Annual Meeting (Poster 55); 2004; Hollywood, FL.
    • (2004) Orthopaedic Trauma Association Annual Meeting
    • Linke, B.1    Schwieger, K.2    Bursic, D.3
  • 15
    • 0023633768 scopus 로고
    • Fixation of displaced femoral neck fractures. A comparison between sliding screw plate and four cancellous bone screws
    • Madsen F, Linde F, Andersen E, et al. Fixation of displaced femoral neck fractures. A comparison between sliding screw plate and four cancellous bone screws. Acta Orthop Scand. 1987;58:212-216.
    • (1987) Acta Orthop Scand , vol.58 , pp. 212-216
    • Madsen, F.1    Linde, F.2    Andersen, E.3
  • 16
    • 0033093073 scopus 로고    scopus 로고
    • Internal fixation of femoral neck fractures with posterior comminution: A biomechanical study
    • Kauffman JI, Simon JA, Kummer FJ, et al. Internal fixation of femoral neck fractures with posterior comminution: a biomechanical study. J Orthop Trauma. 1999;13:155-159.
    • (1999) J Orthop Trauma , vol.13 , pp. 155-159
    • Kauffman, J.I.1    Simon, J.A.2    Kummer, F.J.3
  • 19
    • 0031771032 scopus 로고    scopus 로고
    • Femoral neck fracture fixation: A biomechanical study of two cannulated screw placement techniques
    • Booth KC, Donaldson TK, Dai QG. Femoral neck fracture fixation: a biomechanical study of two cannulated screw placement techniques. Orthopedics. 1998;21:1173-1176.
    • (1998) Orthopedics , vol.21 , pp. 1173-1176
    • Booth, K.C.1    Donaldson, T.K.2    Dai, Q.G.3
  • 20
    • 0029315622 scopus 로고
    • Quality of reduction and cortical screw support in femoral neck fractures. An analysis of 72 fractures with a new computerized measuring method
    • Lindequist S, Tornkvist H. Quality of reduction and cortical screw support in femoral neck fractures. An analysis of 72 fractures with a new computerized measuring method. J Orthop Trauma. 1995;9:215-221.
    • (1995) J Orthop Trauma , vol.9 , pp. 215-221
    • Lindequist, S.1    Tornkvist, H.2
  • 21
    • 0025118439 scopus 로고
    • Factors predisposing to healing complications after internal fixation of femoral neck fracture. A stepwise logistic regression analysis
    • Alberts KA, Jervaeus J. Factors predisposing to healing complications after internal fixation of femoral neck fracture. A stepwise logistic regression analysis. Clin Orthop. 1990:129-133.
    • (1990) Clin Orthop , pp. 129-133
    • Alberts, K.A.1    Jervaeus, J.2
  • 22
    • 0029680922 scopus 로고    scopus 로고
    • In vitro femoral stiffness after femoral neck osteotomy and osteosynthesis with defined surgical errors
    • Hernefalk L, Messner K. In vitro femoral stiffness after femoral neck osteotomy and osteosynthesis with defined surgical errors. J Orthop Trauma. 1996;10:416-420.
    • (1996) J Orthop Trauma , vol.10 , pp. 416-420
    • Hernefalk, L.1    Messner, K.2
  • 23
    • 2342502635 scopus 로고    scopus 로고
    • Minimally invasive dynamic hip screw. Prospective randomized trial of two techniques of insertion of a standard dynamic fixation device
    • DOI 10.1097/00005131-200404000-00003
    • Alobaid A, Harvey EJ, Elder GM, et al. Minimally invasive dynamic hip screw: prospective randomized trial of two techniques of insertion of a standard dynamic fixation device. J Orthop Trauma. 2004;18:207-212. (Pubitemid 38578784)
    • (2004) Journal of Orthopaedic Trauma , vol.18 , Issue.4 , pp. 207-212
    • Alobaid, A.1    Harvey, E.J.2    Elder, G.M.3    Lander, P.4    Guy, P.5    Reindl, R.6
  • 24
    • 0031923934 scopus 로고    scopus 로고
    • Choice of implants for internal fixation of femoral neck fractures: Meta analysis of 25 randomized trials including 4,925 patients
    • Parker MJ, Blundell BR. Choice of implants for internal fixation of femoral neck fractures: meta analysis of 25 randomized trials including 4,925 patients. Acta Orthop Scand. 1998;69:138-143.
    • (1998) Acta Orthop Scand , vol.69 , pp. 138-143
    • Parker, M.J.1    Blundell, B.R.2
  • 25
    • 0026033659 scopus 로고
    • Three cancellous bone screws versus a screw-angle plate in the treatment of Garden I and II fractures of the femoral neck
    • Kuokkanen H, Korkala O, Antti-Poika I, et al. Three cancellous bone screws versus a screw-angle plate in the treatment of Garden I and II fractures of the femoral neck. Acta Orthop Belg. 1991;57:53-57.
    • (1991) Acta Orthop Belg , vol.57 , pp. 53-57
    • Kuokkanen, H.1    Korkala, O.2    Antti-Poika, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.