1
-
-
0012336633
-
-
Architectural & Industrial Press, Beijing
-
Zhao R.Y., Fan C.Y., Xue D.H., and Qian Y.M. Air conditioning. 3rd ed. (2003), Architectural & Industrial Press, Beijing
-
(2003)
Air conditioning. 3rd ed.
-
-
Zhao, R.Y.1
Fan, C.Y.2
Xue, D.H.3
Qian, Y.M.4
-
4
-
-
0025529847
-
Performance studies for an experimental solar open-cycle liquid desiccant air dehumidification system
-
Patnaik S., Lenz T.G., and Lof G.O.G. Performance studies for an experimental solar open-cycle liquid desiccant air dehumidification system. Solar Energy 44 3 (1990) 123-135
-
(1990)
Solar Energy
, vol.44
, Issue.3
, pp. 123-135
-
-
Patnaik, S.1
Lenz, T.G.2
Lof, G.O.G.3
-
5
-
-
0037052954
-
Study of an aqueous lithium chloride desiccant system: air dehumidification and desiccant regeneration
-
Fumo N., and Goswami D.Y. Study of an aqueous lithium chloride desiccant system: air dehumidification and desiccant regeneration. Solar Energy 72 4 (2002) 351-361
-
(2002)
Solar Energy
, vol.72
, Issue.4
, pp. 351-361
-
-
Fumo, N.1
Goswami, D.Y.2
-
6
-
-
51249101093
-
Comparative experimental drift study between a dry and adiabatic fluid cooler and a cooling tower
-
Lucas M., Martinez P.J., and Viedma A. Comparative experimental drift study between a dry and adiabatic fluid cooler and a cooling tower. International Journal of Refrigeration 31 7 (2008) 1169-1175
-
(2008)
International Journal of Refrigeration
, vol.31
, Issue.7
, pp. 1169-1175
-
-
Lucas, M.1
Martinez, P.J.2
Viedma, A.3
-
7
-
-
19044381878
-
Determination of air-water mass transfer coefficient and drop of pressure in wet curtain
-
Ge K.S., Wang Q., and Ren D.F. Determination of air-water mass transfer coefficient and drop of pressure in wet curtain. Journal of China Agriculture University 4 2 (1999) 82-83
-
(1999)
Journal of China Agriculture University
, vol.4
, Issue.2
, pp. 82-83
-
-
Ge, K.S.1
Wang, Q.2
Ren, D.F.3
-
8
-
-
49049090332
-
Effects of inlet relative humidity and inlet temperature on the performance of counterflow wet cooling tower based on exergy analysis
-
Muangnoi T., Asvapoositkul W., and Wongwises S. Effects of inlet relative humidity and inlet temperature on the performance of counterflow wet cooling tower based on exergy analysis. Energy Conversion and Management 49 10 (2008) 2795-2800
-
(2008)
Energy Conversion and Management
, vol.49
, Issue.10
, pp. 2795-2800
-
-
Muangnoi, T.1
Asvapoositkul, W.2
Wongwises, S.3
-
9
-
-
22344450302
-
Model calculation of air water counter flow heat and mass transfer and comparison with experimental data
-
Song Y.Z. Model calculation of air water counter flow heat and mass transfer and comparison with experimental data. Journal of Chemical and Industrial Engineering 56 6 (2005) 999-1003
-
(2005)
Journal of Chemical and Industrial Engineering
, vol.56
, Issue.6
, pp. 999-1003
-
-
Song, Y.Z.1
-
10
-
-
0021531734
-
Coefficients of heat and mass transfer in a packed bed suitable for solar regeneration of aqueous lithium chloride solutions
-
Lof G.O.G., Lenz T.S., and Rao S. Coefficients of heat and mass transfer in a packed bed suitable for solar regeneration of aqueous lithium chloride solutions. Journal of Solar Energy Engineering 106 4 (1984) 387-392
-
(1984)
Journal of Solar Energy Engineering
, vol.106
, Issue.4
, pp. 387-392
-
-
Lof, G.O.G.1
Lenz, T.S.2
Rao, S.3
-
11
-
-
0036723252
-
Theoretical study on a cross-flow direct evaporative cooler using honeycomb paper as packing material
-
Dai Y.J., and Sumathy K. Theoretical study on a cross-flow direct evaporative cooler using honeycomb paper as packing material. Applied Thermal Engineering 22 13 (2002) 1417-1430
-
(2002)
Applied Thermal Engineering
, vol.22
, Issue.13
, pp. 1417-1430
-
-
Dai, Y.J.1
Sumathy, K.2
-
12
-
-
42749086525
-
Coupled heat and mass transfer characteristic in packed bed dehumidifier/regenerator using liquid desiccant
-
Liu X.H., and Jiang Y. Coupled heat and mass transfer characteristic in packed bed dehumidifier/regenerator using liquid desiccant. Energy Conversion and Management 49 6 (2008) 1357-1366
-
(2008)
Energy Conversion and Management
, vol.49
, Issue.6
, pp. 1357-1366
-
-
Liu, X.H.1
Jiang, Y.2
-
13
-
-
33847020884
-
Experimental study on dehumidifier and regenerator of liquid desiccant cooling air conditioning system
-
Yin Y.G., Zhang X.S., and Chen Z.Q. Experimental study on dehumidifier and regenerator of liquid desiccant cooling air conditioning system. Building and Environment 42 7 (2007) 2505-2511
-
(2007)
Building and Environment
, vol.42
, Issue.7
, pp. 2505-2511
-
-
Yin, Y.G.1
Zhang, X.S.2
Chen, Z.Q.3
-
14
-
-
0024936126
-
An effectiveness model of liquid-desiccant system heat/mass exchangers
-
Stevens D.I., Braun J.E., and Klein S.A. An effectiveness model of liquid-desiccant system heat/mass exchangers. Solar Energy 42 6 (1989) 449-455
-
(1989)
Solar Energy
, vol.42
, Issue.6
, pp. 449-455
-
-
Stevens, D.I.1
Braun, J.E.2
Klein, S.A.3
-
15
-
-
36849021089
-
Corrections to the simple effectiveness-NTU method for counterflow cooling towers and packed bed liquid desiccant-air contact systems
-
Ren C.Q. Corrections to the simple effectiveness-NTU method for counterflow cooling towers and packed bed liquid desiccant-air contact systems. International Journal of Heat and Mass Transfer 51 1-2 (2008) 237-245
-
(2008)
International Journal of Heat and Mass Transfer
, vol.51
, Issue.1-2
, pp. 237-245
-
-
Ren, C.Q.1
-
16
-
-
34247483466
-
Analytical solutions of coupled heat and mass transfer processes in liquid desiccant air dehumidifier/regenerator
-
Liu X.H., Jiang Y., Xia J.J., and Chang X.M. Analytical solutions of coupled heat and mass transfer processes in liquid desiccant air dehumidifier/regenerator. Energy Conversion and Management 48 7 (2007) 2221-2232
-
(2007)
Energy Conversion and Management
, vol.48
, Issue.7
, pp. 2221-2232
-
-
Liu, X.H.1
Jiang, Y.2
Xia, J.J.3
Chang, X.M.4
|