메뉴 건너뛰기




Volumn 31, Issue 7, 2008, Pages 1169-1175

Comparative experimental drift study between a dry and adiabatic fluid cooler and a cooling tower

Author keywords

Air water; Comparison; Cooling tower; Experiment; Heat exchanger; Measurement; Performance; Refrigeration system

Indexed keywords

AIR; BUILDINGS; COOLING; COOLING SYSTEMS; COOLING TOWERS; CURING; TOWERS;

EID: 51249101093     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2008.03.004     Document Type: Article
Times cited : (14)

References (23)
  • 1
    • 51249090802 scopus 로고    scopus 로고
    • ASHRAE, 2004. Handbook CD-HVAC Systems and Equipment, Cooling Towers (Chapter 36).
    • ASHRAE, 2004. Handbook CD-HVAC Systems and Equipment, Cooling Towers (Chapter 36).
  • 2
    • 51249121426 scopus 로고    scopus 로고
    • AS-4180.1, 1994. Drift Loss from Cooling Towers - Laboratory Measurement. Part 1: Chloride Balance Method. Standards Australia.
    • AS-4180.1, 1994. Drift Loss from Cooling Towers - Laboratory Measurement. Part 1: Chloride Balance Method. Standards Australia.
  • 3
    • 0027482993 scopus 로고
    • A model for autumn outbreaks of Legionnaries' disease associate with cooling towers, linked to system operation and size
    • Bentham R.H., and Broadbent C.R. A model for autumn outbreaks of Legionnaries' disease associate with cooling towers, linked to system operation and size. Epidemiol. Infect. 111 (1993) 287-295
    • (1993) Epidemiol. Infect. , vol.111 , pp. 287-295
    • Bentham, R.H.1    Broadbent, C.R.2
  • 4
    • 51249108480 scopus 로고    scopus 로고
    • BORM, 20/6/2006. Ayto de Murcia Ordenanza de protección de la atmósfera. Disposición Transitoria única.
    • BORM, 20/6/2006. Ayto de Murcia Ordenanza de protección de la atmósfera. Disposición Transitoria única.
  • 8
    • 51249096625 scopus 로고    scopus 로고
    • DOGV núm. 5311, de 26.07.2006. Orden de la Consellería de Empresa, Universidad y Ciencia, sobre concesión de ayudas para instalaciones industriales de riesgo para la transmisión de la legionelosis, para el ejercicio presupuestario.
    • DOGV núm. 5311, de 26.07.2006. Orden de la Consellería de Empresa, Universidad y Ciencia, sobre concesión de ayudas para instalaciones industriales de riesgo para la transmisión de la legionelosis, para el ejercicio presupuestario.
  • 11
    • 0022554613 scopus 로고
    • Comparison of methods for measurement of cooling tower drift
    • Golay M.W., Glantschnig W.J., and Best F.T. Comparison of methods for measurement of cooling tower drift. Atmos. Environ. 20 2 (1986) 269-291
    • (1986) Atmos. Environ. , vol.20 , Issue.2 , pp. 269-291
    • Golay, M.W.1    Glantschnig, W.J.2    Best, F.T.3
  • 15
    • 51249102229 scopus 로고    scopus 로고
    • Japanese Industrial Standard, JIS B 8609, 1981. Performance Tests of Mechanical Draft Cooling Tower.
    • Japanese Industrial Standard, JIS B 8609, 1981. Performance Tests of Mechanical Draft Cooling Tower.
  • 19
    • 0028372456 scopus 로고
    • A model seasonal and annual cooling tower impacts
    • Policastro A.J., Dunn W.E., and Carhart A. A model seasonal and annual cooling tower impacts. Atmos. Environ. 28 3 (1994) 379-395
    • (1994) Atmos. Environ. , vol.28 , Issue.3 , pp. 379-395
    • Policastro, A.J.1    Dunn, W.E.2    Carhart, A.3
  • 20
    • 0001684264 scopus 로고
    • Impaction of dust and smoke particles
    • Ranz W.E., and Wong J.B. Impaction of dust and smoke particles. Ind. Eng. Chem. (1952) 1371-1380
    • (1952) Ind. Eng. Chem. , pp. 1371-1380
    • Ranz, W.E.1    Wong, J.B.2
  • 21
    • 51249104555 scopus 로고    scopus 로고
    • REAL DECRETO 865, 2003, de 4 de julio. por el que se establecen los criterios higiénico-sanitarios para la prevención y control de la legionelosis.
    • REAL DECRETO 865, 2003, de 4 de julio. por el que se establecen los criterios higiénico-sanitarios para la prevención y control de la legionelosis.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.