메뉴 건너뛰기




Volumn 46, Issue 4, 2009, Pages

Radiometer standard for absolute responsivity calibrations from 950 nm to 1650 nm with 0.05% (κ = 2) uncertainty

Author keywords

[No Author keywords available]

Indexed keywords

ANGULAR RANGE; ANGULAR RESPONSIVITY; COSINE FUNCTIONS; CRYOGENIC RADIOMETERS; FIXED-POINT BLACKBODY; GEOMETRICAL ARRANGEMENTS; INCIDENT BEAMS; INGAAS DETECTORS; NEAR-IR; NONUNIFORMITY; POWER MODES; RESPONSIVITY; SPECTRAL IRRADIANCE; SPECTRAL POWER; THERMODYNAMIC TEMPERATURE; TRAP DETECTORS;

EID: 67650888660     PISSN: 00261394     EISSN: 16817575     Source Type: Journal    
DOI: 10.1088/0026-1394/46/4/S01     Document Type: Article
Times cited : (11)

References (8)
  • 1
    • 0020813630 scopus 로고
    • Silicon photodiode device with 100% external quantum efficiency
    • Zalewski E F and Duda C R 1983 Silicon photodiode device with 100% external quantum efficiency Appl. Opt. 22 2867-73 (Pubitemid 14469226)
    • (1983) Applied Optics , vol.22 , Issue.18 , pp. 2867-2873
    • Zalewski, E.F.1    Duda, C.R.2
  • 2
    • 33845957086 scopus 로고    scopus 로고
    • Facility for spectral irradiance and radiance responsivity calibrations using uniform sources
    • DOI 10.1364/AO.45.008218
    • Brown S W, Eppeldauer G P and Lykke K R 2006 Facility for spectral irradiance and radiance responsivity calibrations using uniform sources Appl. Opt. 45 8218-37 (Pubitemid 46034645)
    • (2006) Applied Optics , vol.45 , Issue.32 , pp. 8218-8237
    • Brown, S.W.1    Eppeldauer, G.P.2    Lykke, K.R.3
  • 3
    • 0037226006 scopus 로고    scopus 로고
    • Spectral characterization of Ge trap detectors and photodiodes used as transfer standards
    • Stock K D, Heine R and Hofer H 2003 Spectral characterization of Ge trap detectors and photodiodes used as transfer standards Metrologia 40 S163-6
    • (2003) Metrologia , vol.40 , Issue.1
    • Stock, K.D.1    Heine, R.2    Hofer, H.3
  • 4
    • 33846876770 scopus 로고    scopus 로고
    • High accuracy measurement of the absolute spectral responsivity of Ge and InGaAs trap detectors by direct calibration against an electrically calibrated cryogenic radiometer in the near-infrared
    • DOI 10.1088/0026-1394/43/6/005, PII S0026139406337358, 005
    • Lopez M, Hofer H and Kuck S 2006 High accuracy measurement of the absolute spectral responsivity of Ge and InGaAs trap detectors by direct calibration against an electrically calibrated cryogenic radiometer in the near-infrared Metrologia 43 508-14 (Pubitemid 46217583)
    • (2006) Metrologia , vol.43 , Issue.6 , pp. 508-514
    • Lopez, M.1    Hofer, H.2    Kuck, S.3
  • 7
    • 0034505549 scopus 로고    scopus 로고
    • Properties of sphere radiometers suitable for high-accuracy cryogenic-radiometer-based calibrations in the near-infrared
    • DOI 10.1088/0026-1394/37/4/2
    • Boivin L P 2000 Properties of sphere radiometers suitable for high-accuracy cryogenic-radiometer-based calibrations in the near-infrared Metrologia 37 273-8 (Pubitemid 32070038)
    • (2000) Metrologia , vol.37 , Issue.4 , pp. 273-278
    • Boivin, L.P.1
  • 8
    • 0001349695 scopus 로고    scopus 로고
    • A transfer standard for optical fiber power metrology
    • Lehman J H and Li X 1999 A transfer standard for optical fiber power metrology Appl. Opt. 38 7164-6 (Pubitemid 129646732)
    • (1999) Applied Optics , vol.38 , Issue.34 , pp. 7164-7166
    • Lehman, J.H.1    Li, X.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.