메뉴 건너뛰기




Volumn 35, Issue 2, 2009, Pages 65-68

Corneal descriptive indices in the fellow eye of unilateral keratoconus

Author keywords

Corneal topography; Subclinical keratoconus

Indexed keywords

ADULT; ARTICLE; CLINICAL FEATURE; CONTROLLED STUDY; CORNEA CURVATURE; CORNEA THICKNESS; FEMALE; HUMAN; KERATOCONUS; KERATOMETRY; MAJOR CLINICAL STUDY; MALE; PARAMETER; PRIORITY JOURNAL; REFERENCE VALUE; REFRACTIVE SURGERY; RELATIVE; SENSITIVITY AND SPECIFICITY; SLIT LAMP;

EID: 67650764279     PISSN: 15422321     EISSN: None     Source Type: Journal    
DOI: 10.1097/ICL.0b013e318198be6e     Document Type: Article
Times cited : (10)

References (25)
  • 2
  • 3
    • 34248648768 scopus 로고    scopus 로고
    • Changes in the balance of the tissue inhibitor of matrix metalloproteinases (TIMPs)-1 and -3 may promote keratocyte apoptosis in keratoconus
    • Matthews FJ, Cook SD, Majid MA, et al. Changes in the balance of the tissue inhibitor of matrix metalloproteinases (TIMPs)-1 and -3 may promote keratocyte apoptosis in keratoconus. Exp Eye Res 2007;84:1125-1134.
    • (2007) Exp Eye Res , vol.84 , pp. 1125-1134
    • Matthews, F.J.1    Cook, S.D.2    Majid, M.A.3
  • 4
    • 22144437404 scopus 로고    scopus 로고
    • Changes in collagen orientation and distribution in keratoconus corneas
    • Meek KM, Tuft SJ, Huang Y, et al. Changes in collagen orientation and distribution in keratoconus corneas. Invest Ophthalmol Vis Sci 2005;46: 1948-1956.
    • (2005) Invest Ophthalmol Vis Sci , vol.46 , pp. 1948-1956
    • Meek, K.M.1    Tuft, S.J.2    Huang, Y.3
  • 5
    • 33846807704 scopus 로고    scopus 로고
    • A study of corneal thickness, shape and collagen organisation in keratoconus using videokeratography and X-ray scattering techniques
    • Hayes S, Boote C, Tuft SJ, et al. A study of corneal thickness, shape and collagen organisation in keratoconus using videokeratography and X-ray scattering techniques. Exp Eye Res 2007;84:423-434.
    • (2007) Exp Eye Res , vol.84 , pp. 423-434
    • Hayes, S.1    Boote, C.2    Tuft, S.J.3
  • 6
    • 1442299751 scopus 로고    scopus 로고
    • Longitudinal study of the normal eyes in unilateral keratoconus patients
    • Li X, Rabinowitz YS, Rasheed K, et al. Longitudinal study of the normal eyes in unilateral keratoconus patients. Ophthalmology 2004;111:440-446.
    • (2004) Ophthalmology , vol.111 , pp. 440-446
    • Li, X.1    Rabinowitz, Y.S.2    Rasheed, K.3
  • 7
    • 43049117821 scopus 로고    scopus 로고
    • Validation of the Ectasia Risk Score System for preoperative laser in situ keratomileusis screening
    • Randleman JB, Trattler WB, Stulting RD. Validation of the Ectasia Risk Score System for preoperative laser in situ keratomileusis screening. Am J Ophthalmol 2008;145:813-818.
    • (2008) Am J Ophthalmol , vol.145 , pp. 813-818
    • Randleman, J.B.1    Trattler, W.B.2    Stulting, R.D.3
  • 8
    • 4744375690 scopus 로고    scopus 로고
    • Keratoconus: An analysis of corneal asymmetry
    • Burns DM, Johnston FM, Frazer DG, et al. Keratoconus: an analysis of corneal asymmetry. Br J Ophthalmol 2004;88:1252-1255.
    • (2004) Br J Ophthalmol , vol.88 , pp. 1252-1255
    • Burns, D.M.1    Johnston, F.M.2    Frazer, D.G.3
  • 9
    • 34247400590 scopus 로고    scopus 로고
    • Vertical D: A novel topographic pattern in some keratoconus suspects
    • Abad JC, Rubinfeld RS, Del Valle M, et al. Vertical D: A novel topographic pattern in some keratoconus suspects. Ophthalmology 2007;114:1020- 1026.
    • (2007) Ophthalmology , vol.114 , pp. 1020-1026
    • Abad, J.C.1    Rubinfeld, R.S.2    Del Valle, M.3
  • 10
    • 33745216716 scopus 로고    scopus 로고
    • Corneal higher order aberrations: A method to grade keratoconus
    • Alio JL, Shabayek MH. Corneal higher order aberrations: A method to grade keratoconus. J Refract Surg 2006;22:539-545.
    • (2006) J Refract Surg , vol.22 , pp. 539-545
    • Alio, J.L.1    Shabayek, M.H.2
  • 11
    • 29344464132 scopus 로고    scopus 로고
    • Automated decision tree classification of corneal shape
    • Twa MD, Parthasarathy S, Roberts C, et al. Automated decision tree classification of corneal shape. Optom Vis Sci 2005;82:1038-1046.
    • (2005) Optom Vis Sci , vol.82 , pp. 1038-1046
    • Twa, M.D.1    Parthasarathy, S.2    Roberts, C.3
  • 12
    • 1542539822 scopus 로고    scopus 로고
    • Subclinical keratoconus diagnosis by elevation topography]
    • Arntz A, Duran JA, Pijoan JI. [Subclinical keratoconus diagnosis by elevation topography]. Arch Soc Esp Oftalmol 2003;78:659-664.
    • (2003) Arch Soc Esp Oftalmol , vol.78 , pp. 659-664
    • Arntz, A.1    Duran, J.A.2    Pijoan, J.I.3
  • 13
    • 50249156439 scopus 로고    scopus 로고
    • Sensitivity and specificity of posterior corneal elevation measured by pentacam in discriminating kera-toconus/subclinical keratoconus
    • de Sanctis U, Loiacono C, Richiardi L, et al. Sensitivity and specificity of posterior corneal elevation measured by pentacam in discriminating kera-toconus/subclinical keratoconus. Ophthalmology 2008;115:1534-1539.
    • (2008) Ophthalmology , vol.115 , pp. 1534-1539
    • de Sanctis, U.1    Loiacono, C.2    Richiardi, L.3
  • 14
    • 48249105538 scopus 로고    scopus 로고
    • Evaluation of corneal topography with Orbscan II in first-degree relatives of patients with keratoconus
    • Kaya V, Utine CA, Altunsoy M, et al. Evaluation of corneal topography with Orbscan II in first-degree relatives of patients with keratoconus. Cornea 2008;27:531-534.
    • (2008) Cornea , vol.27 , pp. 531-534
    • Kaya, V.1    Utine, C.A.2    Altunsoy, M.3
  • 15
    • 18744405684 scopus 로고    scopus 로고
    • Corneal wavefront aberration measurements to detect keratoconus patients
    • Gobbe M, Guillon M. Corneal wavefront aberration measurements to detect keratoconus patients. Cont Lens Anterior Eye 2005;28:57-66.
    • (2005) Cont Lens Anterior Eye , vol.28 , pp. 57-66
    • Gobbe, M.1    Guillon, M.2
  • 16
    • 33847047157 scopus 로고    scopus 로고
    • Defining subclinical keratoconus using corneal first-surface higher-order aberrations
    • Buhren J, Kuhne C, Kohnen T. Defining subclinical keratoconus using corneal first-surface higher-order aberrations. Am J Ophthalmol 2007;143: 381-389.
    • (2007) Am J Ophthalmol , vol.143 , pp. 381-389
    • Buhren, J.1    Kuhne, C.2    Kohnen, T.3
  • 17
    • 35348974534 scopus 로고    scopus 로고
    • Higher order wavefront aberrations and topography in early and suspected keratoconus
    • Jafri B, Li X, Yang H, et al. Higher order wavefront aberrations and topography in early and suspected keratoconus. J Refract Surg 2007;23: 774-781.
    • (2007) J Refract Surg , vol.23 , pp. 774-781
    • Jafri, B.1    Li, X.2    Yang, H.3
  • 18
    • 0029782159 scopus 로고    scopus 로고
    • Videokeratography database of normal human corneas
    • Rabinowitz YS, Yang H, Brickman Y, et al. Videokeratography database of normal human corneas. Br J Ophthalmol 1996;80:610-616.
    • (1996) Br J Ophthalmol , vol.80 , pp. 610-616
    • Rabinowitz, Y.S.1    Yang, H.2    Brickman, Y.3
  • 19
    • 2342465005 scopus 로고    scopus 로고
    • Videokeratographic anomalies in familial keratoconus
    • Levy D, Hutchings H, Rouland JF, et al. Videokeratographic anomalies in familial keratoconus. Ophthalmology 2004;111:867-874.
    • (2004) Ophthalmology , vol.111 , pp. 867-874
    • Levy, D.1    Hutchings, H.2    Rouland, J.F.3
  • 20
    • 35148818718 scopus 로고    scopus 로고
    • Longitudinal study of keratoconus progression
    • Li X, Yang H, Rabinowitz YS. Longitudinal study of keratoconus progression. Exp Eye Res 2007;85:502-507.
    • (2007) Exp Eye Res , vol.85 , pp. 502-507
    • Li, X.1    Yang, H.2    Rabinowitz, Y.S.3
  • 21
    • 31644450807 scopus 로고    scopus 로고
    • Evaluation of Orbscan II corneal topography in individuals with myopia
    • Wei RH, Lim L, Chan WK, et al. Evaluation of Orbscan II corneal topography in individuals with myopia. Ophthalmology 2006;113:177-183.
    • (2006) Ophthalmology , vol.113 , pp. 177-183
    • Wei, R.H.1    Lim, L.2    Chan, W.K.3
  • 22
    • 34548091647 scopus 로고    scopus 로고
    • Magnitude and orientation of Zernike terms in patients with keratoconus
    • Kosaki R, Maeda N, Bessho K, et al. Magnitude and orientation of Zernike terms in patients with keratoconus. Invest Ophthalmol Vis Sci 2007;48: 3062-3068.
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , pp. 3062-3068
    • Kosaki, R.1    Maeda, N.2    Bessho, K.3
  • 23
    • 0036744789 scopus 로고    scopus 로고
    • Measurement repeatability of corneal aberrations
    • Gobbe M, Guillon M, Maissa C. Measurement repeatability of corneal aberrations. J Refract Surg 2002;18:S567-S571.
    • (2002) J Refract Surg , vol.18
    • Gobbe, M.1    Guillon, M.2    Maissa, C.3
  • 24
    • 35349027232 scopus 로고    scopus 로고
    • Evaluation of higher order ocular aberrations in patients with keratoconus
    • Lim L, Wei RH, Chan WK, et al. Evaluation of higher order ocular aberrations in patients with keratoconus. J Refract Surg 2007;23:825-828.
    • (2007) J Refract Surg , vol.23 , pp. 825-828
    • Lim, L.1    Wei, R.H.2    Chan, W.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.