메뉴 건너뛰기




Volumn , Issue , 2009, Pages 159-162

Simultaneous DNA amplification and detection using an electrode array

Author keywords

Electrochemical sensor; Flow through PCR

Indexed keywords

AMPLICON; CONCENTRATION OF; DETECTION METHODS; DNA AMPLIFICATION; ELECTROCHEMICAL DETECTION; ELECTROCHEMICAL MEASUREMENTS; ELECTRODE ARRAYS; FLOW-THROUGH PCR; IN-SITU; METAL ELECTRODES; MICROFLUIDIC FLOW; MODIFIED ELECTRODES; SOLID-PHASE; SURFACE PASSIVATION;

EID: 67650698313     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/LISSA.2009.4906734     Document Type: Conference Paper
Times cited : (1)

References (8)
  • 1
    • 0022372670 scopus 로고
    • Enzymatic amplification of -globin genomic sequences and restriction site analysis for diagnosis of sickle cell anemia
    • R.K. Saiki, S. Scharf, F.A. Faloona, K.B. Mullis, G.T. Horn, H.A. Erlich, and N. Arnheiml, Enzymatic amplification of -globin genomic sequences and restriction site analysis for diagnosis of sickle cell anemia. Science, 1985, 230, 1350-1354.
    • (1985) Science , vol.230 , pp. 1350-1354
    • Saiki, R.K.1    Scharf, S.2    Faloona, F.A.3    Mullis, K.B.4    Horn, G.T.5    Erlich, H.A.6    Arnheiml, N.7
  • 3
    • 0032011519 scopus 로고    scopus 로고
    • A miniature analytical instrument for nucleic acids based on micromachined silicon reaction chambers
    • M.A. Northrup, B. Benett, D. Hadley, P. Landre, S. Lehew, J. Richards, and P. Stratton, A miniature analytical instrument for nucleic acids based on micromachined silicon reaction chambers. Anal. Chem., 1998, 70, 918-922.
    • (1998) Anal. Chem , vol.70 , pp. 918-922
    • Northrup, M.A.1    Benett, B.2    Hadley, D.3    Landre, P.4    Lehew, S.5    Richards, J.6    Stratton, P.7
  • 6
    • 0025207507 scopus 로고
    • Miniaturized total chemical analysis systems: A novel concept for chemical sensing
    • A. Manz, N. Graber, and H.M. Widmer, Miniaturized total chemical analysis systems: a novel concept for chemical sensing. Sens. Actuators, B, 1990, 1, 244-248.
    • (1990) Sens. Actuators, B , vol.1 , pp. 244-248
    • Manz, A.1    Graber, N.2    Widmer, H.M.3
  • 8
    • 0032524099 scopus 로고    scopus 로고
    • Chemical amplification: Continuous-flow PCR on a chip
    • M.U. Kopp, A.J. Mello, and A. Manz, Chemical amplification: continuous-flow PCR on a chip. Science, 1998, 280, 1046-1048.
    • (1998) Science , vol.280 , pp. 1046-1048
    • Kopp, M.U.1    Mello, A.J.2    Manz, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.