메뉴 건너뛰기




Volumn 33, Issue 12, 2009, Pages 91-96

A low voltage ride-through control strategy of permanent magnet direct-driven wind turbine under grid faults

Author keywords

Direct driven; Grid faults; Low voltage ride through (LVRT); Permanent magnet synchronous generator (PMSG); Wind power generation

Indexed keywords

DIRECT-DRIVEN; GRID FAULTS; LOW VOLTAGE RIDE-THROUGH (LVRT); PERMANENT MAGNET SYNCHRONOUS GENERATOR (PMSG); WIND-POWER GENERATION;

EID: 67650555459     PISSN: 10001026     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (58)

References (12)
  • 1
    • 33244483622 scopus 로고    scopus 로고
    • Control of permanent-magnet generators applied to variable-speed wind-energy systems connected to the grid
    • CHINCHILLA M, ARNALTES S, BURGOS J C. Control of permanent-magnet generators applied to variable-speed wind-energy systems connected to the grid. IEEE Trans on Energy Conversion, 2006, 21 (1): 130-135.
    • (2006) IEEE Trans on Energy Conversion , vol.21 , Issue.1 , pp. 130-135
    • Chinchilla, M.1    Arnaltes, S.2    Burgos, J.C.3
  • 2
    • 33744513173 scopus 로고    scopus 로고
    • A neutral-point clamped converter system for direct-drive variable-speed wind power unit
    • YAZDANI A, IRAVANI R. A neutral-point clamped converter system for direct-drive variable-speed wind power unit. IEEE Trans on Energy Conversion, 2006, 21 (2): 596-607.
    • (2006) IEEE Trans on Energy Conversion , vol.21 , Issue.2 , pp. 596-607
    • Yazdani, A.1    Iravani, R.2
  • 3
    • 33846348309 scopus 로고    scopus 로고
    • Direct-control grid-connected power with none direct speed measurement of direct-drive wind generator
    • XU Ke, HU Minqiang, ZHENG Jianyong, et al. Direct-control grid-connected power with none direct speed measurement of direct-drive wind generator. Automation of Electric Power Systems, 2006, 30 (23): 43-47.
    • (2006) Automation of Electric Power Systems , vol.30 , Issue.23 , pp. 43-47
    • Xu, K.1    Hu, M.2    Zheng, J.3
  • 4
    • 41649115664 scopus 로고    scopus 로고
    • Application of parallel back-to-back PWM converter on the direct-drive wind power system
    • LI Jianlin, GAO Zhigang, HU Shuju, et al. Application of parallel back-to-back PWM converter on the direct-drive wind power system. Automation of Electric Power Systems, 2008, 32 (5): 59-62.
    • (2008) Automation of Electric Power Systems , vol.32 , Issue.5 , pp. 59-62
    • Li, J.1    Gao, Z.2    Hu, S.3
  • 5
    • 47049125828 scopus 로고    scopus 로고
    • A sensorless control method for direct driven wind turbines based on position observation
    • WANG Lingxiang, ZHANG Xing, ZHANG Chongwei, et al. A sensorless control method for direct driven wind turbines based on position observation. Automation of Electric Power Systems, 2008, 32 (12): 78-82.
    • (2008) Automation of Electric Power Systems , vol.32 , Issue.12 , pp. 78-82
    • Wang, L.1    Zhang, X.2    Zhang, C.3
  • 6
    • 56349138249 scopus 로고    scopus 로고
    • Coordinated control strategy of back-to-back PWM converter for permanent magnet direct-driven wind turbine
    • YAO Jun, LIAO Yong, ZHUANG Kai. Coordinated control strategy of back-to-back PWM converter for permanent magnet direct-driven wind turbine. Automation of Electric Power Systems, 2008, 32 (20): 88-97, 107.
    • (2008) Automation of Electric Power Systems , vol.32 , Issue.20
    • Yao, J.1    Liao, Y.2    Zhuang, K.3
  • 8
    • 67650521334 scopus 로고    scopus 로고
    • Low voltage ride-through technologies in wind turbine generation
    • ZHANG Xing, ZHANG Longyun, YANG Shuying, et al. Low voltage ride-through technologies in wind turbine generation. Proceedings of the CSU-EPSA, 2008, 20 (2): 1-8.
    • (2008) Proceedings of the CSU-EPSA , vol.20 , Issue.2 , pp. 1-8
    • Zhang, X.1    Zhang, L.2    Yang, S.3
  • 9
    • 45949089597 scopus 로고    scopus 로고
    • Modeling on converters of direct-driven wind power system and its performance during voltage sags
    • HU Shuju, LI Jianlin, XU Honghua. Modeling on converters of direct-driven wind power system and its performance during voltage sags. High Voltage Engineering, 2008, 34 (5): 949-954.
    • (2008) High Voltage Engineering , vol.34 , Issue.5 , pp. 949-954
    • Hu, S.1    Li, J.2    Xu, H.3
  • 10
    • 67650516277 scopus 로고    scopus 로고
    • Simulation analysis of dc-link Crowbar for direct-drive VSCF wind power system
    • HU Shuju, LI Jianlin, XU Honghua. Simulation analysis of dc-link Crowbar for direct-drive VSCF wind power system. Proceedings of the CSU-EPSA, 2008, 20 (3): 118-123.
    • (2008) Proceedings of the CSU-EPSA , vol.20 , Issue.3 , pp. 118-123
    • Hu, S.1    Li, J.2    Xu, H.3
  • 11
    • 56349144345 scopus 로고    scopus 로고
    • Studies on the low voltage ride through capability of fully converted wind turbine with PMSG
    • LI Jianlin, HU Shuju, KONG Deguo, et al. Studies on the low voltage ride through capability of fully converted wind turbine with PMSG. Automation of Electric Power Systems, 2008, 32 (19): 92-95.
    • (2008) Automation of Electric Power Systems , vol.32 , Issue.19 , pp. 92-95
    • Li, J.1    Hu, S.2    Kong, D.3
  • 12
    • 47049098141 scopus 로고    scopus 로고
    • A control strategy of grid-side converter for AC excited wind turbine under grid short-circuit fault
    • YAO Jun, LIAO Yong. A control strategy of grid-side converter for AC excited wind turbine under grid short-circuit fault. Automation of Electric Power Systems, 2008, 32 (12): 83-88.
    • (2008) Automation of Electric Power Systems , vol.32 , Issue.12 , pp. 83-88
    • Yao, J.1    Liao, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.