메뉴 건너뛰기




Volumn 32, Issue 19, 2008, Pages 92-95

Studies on the low voltage ride through capability of fully converted wind turbine with PMSG

Author keywords

Full power converter; Low voltage ride through (LVRT); Permanent magnet synchronous generator (PMSG); STATCOM; Voltage sags; Wind power system

Indexed keywords

ELECTRIC GENERATORS; ELECTRIC POWER FACTOR; ELECTRIC POWER SYSTEMS; ELECTRIC POWER TRANSMISSION NETWORKS; ENGINES; HYDRAULIC MACHINERY; HYDRAULIC MOTORS; MAGNETIC DEVICES; MAGNETS; PERMANENT MAGNETS; POWER CONVERTERS; POWER TRANSMISSION; RENEWABLE ENERGY RESOURCES; SYNCHRONOUS GENERATORS; SYNCHRONOUS MACHINERY; TURBINES; VOLTAGE STABILIZING CIRCUITS; WIND TURBINES;

EID: 56349144345     PISSN: 10001026     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (53)

References (12)
  • 1
    • 33751574240 scopus 로고    scopus 로고
    • Strategy to cope with the VSCF-DFIG during voltage dip
    • LI Jianlin, XU Hongyan, LIANG Liang, et al. Strategy to cope with the VSCF-DFIG during voltage dip. Automation of Electric Power Systems, 2006, 30(19): 65-68.
    • (2006) Automation of Electric Power Systems , vol.30 , Issue.19 , pp. 65-68
    • Li, J.1    Xu, H.2    Liang, L.3
  • 3
    • 34547974385 scopus 로고    scopus 로고
    • Modeling and control of doubly-fed induction generator (DFIG) based wind-power generation system under unbalanced grid voltage conditions
    • HU Jiabing, HE Yikang, GUO Xiaoming, et al. Modeling and control of doubly-fed induction generator (DFIG) based wind-power generation system under unbalanced grid voltage conditions. Automation of Electric Power Systems, 2007, 31(14): 47-56.
    • (2007) Automation of Electric Power Systems , vol.31 , Issue.14 , pp. 47-56
    • Hu, J.1    He, Y.2    Guo, X.3
  • 4
    • 32344450732 scopus 로고    scopus 로고
    • Optimized active power reference based maximum wind energy tracking control strategy
    • HU Jiabing, HE Yikang, LIU Qihui. Optimized active power reference based maximum wind energy tracking control strategy. Automation of Electric Power Systems, 2005, 29(24): 32-38.
    • (2005) Automation of Electric Power Systems , vol.29 , Issue.24 , pp. 32-38
    • Hu, J.1    He, Y.2    Liu, Q.3
  • 5
    • 41649115664 scopus 로고    scopus 로고
    • Application of parallel back-to-back PWM converter on the direct-drive wind power system
    • LI Jianlin, GAO Zhigang, HU Shuju. Application of parallel back-to-back PWM converter on the direct-drive wind power system. Automation of Electric Power Systems, 2008, 32(5): 59-62.
    • (2008) Automation of Electric Power Systems , vol.32 , Issue.5 , pp. 59-62
    • Li, J.1    Gao, Z.2    Hu, S.3
  • 6
    • 34948910701 scopus 로고    scopus 로고
    • Analysis on the low-voltage-ride-through capability of direct-drive permanent magnetic generator wind turbines
    • HU Shuju, LI Jianlin, XU Honghua. Analysis on the low-voltage-ride-through capability of direct-drive permanent magnetic generator wind turbines. Automation of Electric Power Systems, 2007, 31(17): 73-77.
    • (2007) Automation of Electric Power Systems , vol.31 , Issue.17 , pp. 73-77
    • Hu, S.1    Li, J.2    Xu, H.3
  • 7
    • 40449126129 scopus 로고    scopus 로고
    • Review of voltage sag generator for wind power
    • HU Shuju, LI Jianlin, XU Honghua. Review of voltage sag generator for wind power. Electric Power Automation Equipment, 2008, 28(2): 101-103.
    • (2008) Electric Power Automation Equipment , vol.28 , Issue.2 , pp. 101-103
    • Hu, S.1    Li, J.2    Xu, H.3
  • 8
    • 33749029254 scopus 로고    scopus 로고
    • Impact of large scale wind farm integration on power system transient stability
    • CHI Yongning, WANG Weisheng, LIU Yanhua, et al. Impact of large scale wind farm integration on power system transient stability. Automation of Electric Power Systems, 2006, 30(15): 10-14.
    • (2006) Automation of Electric Power Systems , vol.30 , Issue.15 , pp. 10-14
    • Chi, Y.1    Wang, W.2    Liu, Y.3
  • 9
    • 44849135662 scopus 로고    scopus 로고
    • Dynamic characteristics analysis of STATCOM for reactive compensation in wind farm
    • XIANG Zhen, XIE Da, GONG Jinxia, et al. Dynamic characteristics analysis of STATCOM for reactive compensation in wind farm. Automation of Electric Power Systems, 2008, 32(9): 92-95.
    • (2008) Automation of Electric Power Systems , vol.32 , Issue.9 , pp. 92-95
    • Xiang, Z.1    Xie, D.2    Gong, J.3
  • 10
    • 34547967723 scopus 로고    scopus 로고
    • A comparison of the integration types of large wind farm
    • CHANG Yong, XU Zheng, ZHENG Yuping. A comparison of the integration types of large wind farm. Automation of Electric Power Systems, 2007, 31(14): 70-75.
    • (2007) Automation of Electric Power Systems , vol.31 , Issue.14 , pp. 70-75
    • Chang, Y.1    Xu, Z.2    Zheng, Y.3
  • 12
    • 45949089597 scopus 로고    scopus 로고
    • Modeling on converters of direct-driven wind power system and its performance during voltage sags
    • HU Shuju, LI Jianlin, XU Honghua. Modeling on converters of direct-driven wind power system and its performance during voltage sags. High Voltage Engineering, 2008, 34(5): 949-954.
    • (2008) High Voltage Engineering , vol.34 , Issue.5 , pp. 949-954
    • Hu, S.1    Li, J.2    Xu, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.