메뉴 건너뛰기




Volumn 67, Issue 8, 2009, Pages 1595-1599

Factors Associated With the Stability of Mini-Implants for Orthodontic Anchorage: A Study of 414 Samples in Taiwan

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; COHORT ANALYSIS; FEMALE; HUMAN; HYGIENE; MAJOR CLINICAL STUDY; MALE; MANDIBLE; MAXILLA; ORTHODONTICS; PROSTHESIS FAILURE; PROSTHESIS LOOSENING; RELIABILITY; TAIWAN; TOOTH IMPLANTATION;

EID: 67650482021     PISSN: 02782391     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joms.2009.04.015     Document Type: Article
Times cited : (95)

References (25)
  • 1
    • 0036636623 scopus 로고    scopus 로고
    • Orthodontic anchorage with specific fixtures: Related study analysis
    • Favero L., Brollo P., and Bressan E. Orthodontic anchorage with specific fixtures: Related study analysis. Am J Orthod Dentofacial Orthop 122 (2002) 84
    • (2002) Am J Orthod Dentofacial Orthop , vol.122 , pp. 84
    • Favero, L.1    Brollo, P.2    Bressan, E.3
  • 2
    • 0035492033 scopus 로고    scopus 로고
    • Micro-implant anchorage for lingual treatment of a skeletal Class II malocclusion
    • Lee JS, Park HS, Kyung HM: Micro-implant anchorage for lingual treatment of a skeletal Class II malocclusion. J Clin Orthod 35:643
    • J Clin Orthod , vol.35 , pp. 643
    • Lee, J.S.1    Park, H.S.2    Kyung, H.M.3
  • 3
    • 0035407943 scopus 로고    scopus 로고
    • Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion
    • Park H.S., Bae S.M., Kyung H.M., et al. Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion. J Clin Orthod 35 (2001) 417
    • (2001) J Clin Orthod , vol.35 , pp. 417
    • Park, H.S.1    Bae, S.M.2    Kyung, H.M.3
  • 4
    • 0036580590 scopus 로고    scopus 로고
    • Clinical application of micro-implant anchorage
    • Bae S.M., Park H.S., Kyung H.M., et al. Clinical application of micro-implant anchorage. J Clin Orthod 36 (2002) 298
    • (2002) J Clin Orthod , vol.36 , pp. 298
    • Bae, S.M.1    Park, H.S.2    Kyung, H.M.3
  • 5
    • 5444263274 scopus 로고    scopus 로고
    • The lingual plain-wire system with micro-implant anchorage
    • Kyung H.M., Park H.S., Bae S.M., et al. The lingual plain-wire system with micro-implant anchorage. J Clin Orthod 38 (2004) 388
    • (2004) J Clin Orthod , vol.38 , pp. 388
    • Kyung, H.M.1    Park, H.S.2    Bae, S.M.3
  • 6
    • 4143107769 scopus 로고    scopus 로고
    • Micro-implant anchorage for forced eruption of impacted canines
    • Park H.S., Kwon O.W., and Sung J.H. Micro-implant anchorage for forced eruption of impacted canines. J Clin Orthod 38 (2004) 297
    • (2004) J Clin Orthod , vol.38 , pp. 297
    • Park, H.S.1    Kwon, O.W.2    Sung, J.H.3
  • 7
    • 21444451316 scopus 로고    scopus 로고
    • Mechanical properties of three different commercially available miniscrews for skeletal anchorage
    • Carano A., Lonardo P., Velo S., et al. Mechanical properties of three different commercially available miniscrews for skeletal anchorage. Prog Orthod 6 (2005) 82
    • (2005) Prog Orthod , vol.6 , pp. 82
    • Carano, A.1    Lonardo, P.2    Velo, S.3
  • 8
    • 33644986334 scopus 로고    scopus 로고
    • Maxillary molar intrusion with micro-implant anchorage (MIA)
    • Park H.S., Jang B.K., and Kyung H.M. Maxillary molar intrusion with micro-implant anchorage (MIA). Aust Orthod J 21 (2005) 129
    • (2005) Aust Orthod J , vol.21 , pp. 129
    • Park, H.S.1    Jang, B.K.2    Kyung, H.M.3
  • 9
    • 0141921987 scopus 로고    scopus 로고
    • Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage
    • Miyawaki S., Koyama I., Inoue M., et al. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 124 (2003) 373
    • (2003) Am J Orthod Dentofacial Orthop , vol.124 , pp. 373
    • Miyawaki, S.1    Koyama, I.2    Inoue, M.3
  • 10
    • 1342322625 scopus 로고    scopus 로고
    • A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage
    • Cheng S.J., Tseng I.Y., Lee J.J., et al. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 19 (2004) 100
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 100
    • Cheng, S.J.1    Tseng, I.Y.2    Lee, J.J.3
  • 11
    • 33745835122 scopus 로고    scopus 로고
    • Factors affecting the clinical success of screw implants used as orthodontic anchorage
    • Park H.S., Jeong S.H., and Kwon O.W. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 130 (2006) 18
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 18
    • Park, H.S.1    Jeong, S.H.2    Kwon, O.W.3
  • 12
    • 0020322562 scopus 로고
    • Thermal injury to bone. A vital-microscopic description of heat effects
    • Eriksson A., Albrektsson T., Grane B., et al. Thermal injury to bone. A vital-microscopic description of heat effects. Int J Oral Surg 11 (1982) 115
    • (1982) Int J Oral Surg , vol.11 , pp. 115
    • Eriksson, A.1    Albrektsson, T.2    Grane, B.3
  • 13
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbit
    • Eriksson A.R., and Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbit. J Prosthet Dent 50 (1983) 101
    • (1983) J Prosthet Dent , vol.50 , pp. 101
    • Eriksson, A.R.1    Albrektsson, T.2
  • 14
    • 0031152012 scopus 로고    scopus 로고
    • Influence of different parameters on bone heating and drilling time in implantology
    • Reingewirtz Y., Szmukler-Moncler S., and Senger B. Influence of different parameters on bone heating and drilling time in implantology. Clin Oral Implants Res 8 (1997) 189
    • (1997) Clin Oral Implants Res , vol.8 , pp. 189
    • Reingewirtz, Y.1    Szmukler-Moncler, S.2    Senger, B.3
  • 15
    • 0036788376 scopus 로고    scopus 로고
    • Heat generation during implant drilling: The significance of motor speed
    • Sharawy M., Misch C.E., Weller N., et al. Heat generation during implant drilling: The significance of motor speed. J Oral Maxillofac Surg 60 (2002) 1160
    • (2002) J Oral Maxillofac Surg , vol.60 , pp. 1160
    • Sharawy, M.1    Misch, C.E.2    Weller, N.3
  • 16
    • 0029683215 scopus 로고    scopus 로고
    • The effect of speed, pressure, and time on bone temperature during the drilling of implant sites
    • Brisman D.L. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites. Int J Oral Maxillofac Implants 11 (1996) 35
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 35
    • Brisman, D.L.1
  • 17
    • 0343129393 scopus 로고
    • Microdamage at bone-implant interface affects bone remodeling activity
    • Hoshaw S.J., Watson J.T., Schaffler M.B., et al. Microdamage at bone-implant interface affects bone remodeling activity. Trans Orthop Res Soc 20 (1995) 188
    • (1995) Trans Orthop Res Soc , vol.20 , pp. 188
    • Hoshaw, S.J.1    Watson, J.T.2    Schaffler, M.B.3
  • 18
    • 28744436524 scopus 로고    scopus 로고
    • Remodeling of bone surrounding at the implant interface
    • Garetto L.P., Turner C.H., Duncan R.L., et al. (Eds), School of Dentistry, Indiana University, Indianapolis
    • Garetto L.P., and Tricker N.D. Remodeling of bone surrounding at the implant interface. In: Garetto L.P., Turner C.H., Duncan R.L., et al. (Eds). Bridging the Gap Between Dental and Orthopedic Implants (2002), School of Dentistry, Indiana University, Indianapolis 89-99
    • (2002) Bridging the Gap Between Dental and Orthopedic Implants , pp. 89-99
    • Garetto, L.P.1    Tricker, N.D.2
  • 19
    • 67650415364 scopus 로고    scopus 로고
    • Mechanisms of bone adaptation to miniscrew implants
    • Cope J.B. (Ed), Under Dog Media, Dallas, TX
    • Huja S.S. Mechanisms of bone adaptation to miniscrew implants. In: Cope J.B. (Ed). OrthoTADs: The Clinical Guide and Atlas (2007), Under Dog Media, Dallas, TX 23-33
    • (2007) OrthoTADs: The Clinical Guide and Atlas , pp. 23-33
    • Huja, S.S.1
  • 20
    • 85016033318 scopus 로고
    • Mechanical loading of Brånemark implants affects interfacial bone modeling and remodeling
    • Hoshaw S.J., Brunski J.B., and Cochran G.V.B. Mechanical loading of Brånemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 9 (1994) 345
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 345
    • Hoshaw, S.J.1    Brunski, J.B.2    Cochran, G.V.B.3
  • 21
    • 0034853307 scopus 로고    scopus 로고
    • The effect of right or left-handedness on oral hygiene
    • Tezel A., Orbak R., and Canakci V. The effect of right or left-handedness on oral hygiene. Int J Neurosci 109 (2001) 1
    • (2001) Int J Neurosci , vol.109 , pp. 1
    • Tezel, A.1    Orbak, R.2    Canakci, V.3
  • 22
    • 0025490304 scopus 로고
    • The effect of toothbrushing frequency, toothbrushing hand, sex and social class on the incidence of plaque, gingivitis and pocketing in adolescents: A longitudinal cohort study
    • Addy M., Dummer P.M., Hunter M.L., et al. The effect of toothbrushing frequency, toothbrushing hand, sex and social class on the incidence of plaque, gingivitis and pocketing in adolescents: A longitudinal cohort study. Community Dent Health 7 (1990) 237
    • (1990) Community Dent Health , vol.7 , pp. 237
    • Addy, M.1    Dummer, P.M.2    Hunter, M.L.3
  • 23
    • 0034585233 scopus 로고    scopus 로고
    • Implant survival to 36 months as related to length and diameter
    • Winkler S., Morris H.F., and Ochi S. Implant survival to 36 months as related to length and diameter. Ann Periodontol 5 (2000) 22
    • (2000) Ann Periodontol , vol.5 , pp. 22
    • Winkler, S.1    Morris, H.F.2    Ochi, S.3
  • 24
    • 0042420609 scopus 로고    scopus 로고
    • A prospective multicenter clinical trial of 3i machined-surface implants: Results after 6 years of follow-up
    • Weng D., Jacobson Z., Tarnow D., et al. A prospective multicenter clinical trial of 3i machined-surface implants: Results after 6 years of follow-up. Int J Oral Maxillofac Implants 18 (2003) 417
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 417
    • Weng, D.1    Jacobson, Z.2    Tarnow, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.