메뉴 건너뛰기




Volumn 2, Issue 7, 2009, Pages 816-824

Diagnostic Accuracy of Computed Tomography Angiography in Patients After Bypass Grafting. Comparison With Invasive Coronary Angiography

Author keywords

angiography; bypass; CABG; computed tomography; dual source

Indexed keywords

IOPROMIDE;

EID: 67650296703     PISSN: 1936878X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcmg.2009.02.010     Document Type: Article
Times cited : (100)

References (22)
  • 1
    • 4143091550 scopus 로고    scopus 로고
    • Native coronary disease progression exceeds failed revascularization as cause of angina after five years in the Bypass Angioplasty Revascularization Investigation (BARI)
    • Alderman E.L., Kip K.E., Whitlow P.L., et al. Native coronary disease progression exceeds failed revascularization as cause of angina after five years in the Bypass Angioplasty Revascularization Investigation (BARI). J Am Coll Cardiol 44 (2004) 766-774
    • (2004) J Am Coll Cardiol , vol.44 , pp. 766-774
    • Alderman, E.L.1    Kip, K.E.2    Whitlow, P.L.3
  • 2
    • 33947429556 scopus 로고    scopus 로고
    • Use of 64-slice CT in symptomatic patients after coronary bypass surgery: evaluation of grafts and coronary arteries
    • Malagutti P., Nieman K., Meijboom W.B., et al. Use of 64-slice CT in symptomatic patients after coronary bypass surgery: evaluation of grafts and coronary arteries. Eur Heart J 28 (2007) 1879-1885
    • (2007) Eur Heart J , vol.28 , pp. 1879-1885
    • Malagutti, P.1    Nieman, K.2    Meijboom, W.B.3
  • 3
    • 33751574663 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation
    • quiz 2334
    • Ropers D., Pohle F.K., Kuettner A., et al. Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation. Circulation 114 (2006) 2334-2341 quiz 2334
    • (2006) Circulation , vol.114 , pp. 2334-2341
    • Ropers, D.1    Pohle, F.K.2    Kuettner, A.3
  • 4
    • 32844464236 scopus 로고    scopus 로고
    • Contrast-enhanced coronary artery visualization by dual-source computed tomography: initial experience
    • Achenbach S., Ropers D., Kuettner A., et al. Contrast-enhanced coronary artery visualization by dual-source computed tomography: initial experience. Eur J Radiol 57 (2006) 331-335
    • (2006) Eur J Radiol , vol.57 , pp. 331-335
    • Achenbach, S.1    Ropers, D.2    Kuettner, A.3
  • 5
    • 34547792220 scopus 로고    scopus 로고
    • Reliable high-speed coronary computed tomography in symptomatic patients
    • Weustink A.C., Meijboom W.B., Mollet N.R., et al. Reliable high-speed coronary computed tomography in symptomatic patients. J Am Coll Cardiol 50 (2007) 786-794
    • (2007) J Am Coll Cardiol , vol.50 , pp. 786-794
    • Weustink, A.C.1    Meijboom, W.B.2    Mollet, N.R.3
  • 6
    • 35148867562 scopus 로고    scopus 로고
    • Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease
    • Leber A.W., Johnson T., Becker A., et al. Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease. Eur Heart J 28 (2007) 2354-2360
    • (2007) Eur Heart J , vol.28 , pp. 2354-2360
    • Leber, A.W.1    Johnson, T.2    Becker, A.3
  • 7
    • 23944513257 scopus 로고    scopus 로고
    • Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot
    • Flohr T.G., Stierstorfer K., Ulzheimer S., Bruder H., Primak A.N., and McCollough C.H. Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot. Med Phys 32 (2005) 2536-2547
    • (2005) Med Phys , vol.32 , pp. 2536-2547
    • Flohr, T.G.1    Stierstorfer, K.2    Ulzheimer, S.3    Bruder, H.4    Primak, A.N.5    McCollough, C.H.6
  • 8
    • 31444454089 scopus 로고    scopus 로고
    • First performance evaluation of a dual-source CT (DSCT) system
    • Flohr T.G., McCollough C.H., Bruder H., et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16 (2006) 256-268
    • (2006) Eur Radiol , vol.16 , pp. 256-268
    • Flohr, T.G.1    McCollough, C.H.2    Bruder, H.3
  • 9
    • 0016490238 scopus 로고
    • A reporting system on patients evaluated for coronary artery disease: report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association
    • Austen W.G., Edwards J.E., Frye R.L., et al. A reporting system on patients evaluated for coronary artery disease: report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51 (1975) 5-40
    • (1975) Circulation , vol.51 , pp. 5-40
    • Austen, W.G.1    Edwards, J.E.2    Frye, R.L.3
  • 10
    • 34248659948 scopus 로고    scopus 로고
    • Comparison of multidetector 64-slice computed tomographic angiography to coronary angiography to assess the patency of coronary artery bypass grafts
    • Jabara R., Chronos N., Klein L., et al. Comparison of multidetector 64-slice computed tomographic angiography to coronary angiography to assess the patency of coronary artery bypass grafts. Am J Cardiol 99 (2007) 1529-1534
    • (2007) Am J Cardiol , vol.99 , pp. 1529-1534
    • Jabara, R.1    Chronos, N.2    Klein, L.3
  • 11
    • 34547997694 scopus 로고    scopus 로고
    • Evaluation of coronary artery bypass grafts and native coronary arteries using 64-slice multidetector computed tomography
    • Onuma Y., Tanabe K., Chihara R., et al. Evaluation of coronary artery bypass grafts and native coronary arteries using 64-slice multidetector computed tomography. Am Heart J 154 (2007) 519-526
    • (2007) Am Heart J , vol.154 , pp. 519-526
    • Onuma, Y.1    Tanabe, K.2    Chihara, R.3
  • 12
    • 34548262593 scopus 로고    scopus 로고
    • Diagnostic performance of 64-slice computed tomography in evaluation of coronary artery bypass grafts
    • Feuchtner G.M., Schachner T., Bonatti J., et al. Diagnostic performance of 64-slice computed tomography in evaluation of coronary artery bypass grafts. AJR Am J Roentgenol 189 (2007) 574-580
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 574-580
    • Feuchtner, G.M.1    Schachner, T.2    Bonatti, J.3
  • 13
    • 33645473269 scopus 로고    scopus 로고
    • Initial experience with 64-slice cardiac CT: non-invasive visualization of coronary artery bypass grafts
    • Pache G., Saueressig U., Frydrychowicz A., et al. Initial experience with 64-slice cardiac CT: non-invasive visualization of coronary artery bypass grafts. Eur Heart J 27 (2006) 976-980
    • (2006) Eur Heart J , vol.27 , pp. 976-980
    • Pache, G.1    Saueressig, U.2    Frydrychowicz, A.3
  • 14
    • 33847252013 scopus 로고    scopus 로고
    • Improved noninvasive assessment of coronary artery bypass grafts with 64-slice computed tomographic angiography in an unselected patient population
    • Meyer T.S., Martinoff S., Hadamitzky M., et al. Improved noninvasive assessment of coronary artery bypass grafts with 64-slice computed tomographic angiography in an unselected patient population. J Am Coll Cardiol 49 (2007) 946-950
    • (2007) J Am Coll Cardiol , vol.49 , pp. 946-950
    • Meyer, T.S.1    Martinoff, S.2    Hadamitzky, M.3
  • 16
    • 33749061448 scopus 로고    scopus 로고
    • ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography,Society for Cardiovascular Magnetic Resonance
    • Hendel R.C., Patel M.R., Kramer C.M., et al. ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology. J Am Coll Cardiol 48 (2006) 1475-1497
    • (2006) J Am Coll Cardiol , vol.48 , pp. 1475-1497
    • Hendel, R.C.1    Patel, M.R.2    Kramer, C.M.3
  • 17
    • 33750206253 scopus 로고    scopus 로고
    • Assessment of coronary artery disease by cardiac computed tomography: a scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology
    • Budoff M.J., Achenbach S., Blumenthal R.S., et al. Assessment of coronary artery disease by cardiac computed tomography: a scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology. Circulation 114 (2006) 1761-1791
    • (2006) Circulation , vol.114 , pp. 1761-1791
    • Budoff, M.J.1    Achenbach, S.2    Blumenthal, R.S.3
  • 18
    • 34447338023 scopus 로고    scopus 로고
    • Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing
    • Leschka S., Scheffel H., Desbiolles L., et al. Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing. Invest Radiol 42 (2007) 543-549
    • (2007) Invest Radiol , vol.42 , pp. 543-549
    • Leschka, S.1    Scheffel, H.2    Desbiolles, L.3
  • 19
    • 39049158286 scopus 로고    scopus 로고
    • Radiation dose estimates in dual-source computed tomography coronary angiography
    • Stolzmann P., Scheffel H., Schertler T., et al. Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 18 (2008) 592-599
    • (2008) Eur Radiol , vol.18 , pp. 592-599
    • Stolzmann, P.1    Scheffel, H.2    Schertler, T.3
  • 20
    • 38349134611 scopus 로고    scopus 로고
    • Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
    • Husmann L., Valenta I., Gaemperli O., et al. Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating. Eur Heart J 29 (2008) 191-197
    • (2008) Eur Heart J , vol.29 , pp. 191-197
    • Husmann, L.1    Valenta, I.2    Gaemperli, O.3
  • 21
    • 53749091161 scopus 로고    scopus 로고
    • Dual-source CT in step-and-shoot mode: Noninvasive coronary angiography with low radiation dose
    • Stolzmann P., Leschka S., Scheffel H., et al. Dual-source CT in step-and-shoot mode: Noninvasive coronary angiography with low radiation dose. Radiology 249 (2008) 71-80
    • (2008) Radiology , vol.249 , pp. 71-80
    • Stolzmann, P.1    Leschka, S.2    Scheffel, H.3
  • 22
    • 34447558140 scopus 로고    scopus 로고
    • Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    • Einstein A.J., Henzlova M.J., and Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 298 (2007) 317-323
    • (2007) JAMA , vol.298 , pp. 317-323
    • Einstein, A.J.1    Henzlova, M.J.2    Rajagopalan, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.