메뉴 건너뛰기




Volumn 24, Issue 6, 2008, Pages 494-502

Optimization of multibiosensor usage for inhibitory analysis of toxins

Author keywords

Immobilized enzymes; Inhibitory analysis; Multibiosensor; PH sensitive field effect transistors; Toxins

Indexed keywords


EID: 67650130425     PISSN: 02337657     EISSN: 19936842     Source Type: Journal    
DOI: 10.7124/bc.0007C2     Document Type: Article
Times cited : (7)

References (15)
  • 2
    • 77956169592 scopus 로고    scopus 로고
    • Formaldehyde conductometric biosensor based on the recombinant formaldehyde dehydrogenase fromHansenula polymorpha yeast
    • Sosovskaya O. F., Pavlishko G. N., Paryzhak S. Ya., Gonchar M. V., Korpan Ya. I. Formaldehyde conductometric biosensor based on the recombinant formaldehyde dehydrogenase fromHansenula polymorpha yeast Biopolym. Cell. 2008; 24(2):135-141
    • (2008) Biopolym. Cell , vol.24 , Issue.2 , pp. 135-141
    • Sosovskaya, O.F.1    Pavlishko, G.N.2    Paryzhak, S.Y.3    Gonchar, M.V.4    Korpan, Y.A.I.5
  • 8
    • 0038357679 scopus 로고    scopus 로고
    • Development and optimisation of biosensors based on pH-sensitive field effect transistors and cholinesterases for sensitive detection of solanaceous glycoalkaloids
    • Arkhypova V. N., Dzyadevych S. V., Soldatkin A. P., El’skaya A. V., Martelet C., Jaffrezic-Renault N. Development and optimisation of biosensors based on pH-sensitive field effect transistors and cholinesterases for sensitive detection of solanaceous glycoalkaloids. Biosensors and Bioelectronics 2003 18 P. 1047-1053.
    • (2003) Biosensors and Bioelectronics , vol.18 , pp. 1047-1053
    • Arkhypova, V.N.1    Dzyadevych, S.V.2    Soldatkin, A.P.3    El’Skaya, A.V.4    Martelet, C.5    Jaffrezic-Renault, N.6
  • 11
  • 12
    • 33646797444 scopus 로고    scopus 로고
    • Multi-sensor array used as an «electronic tongue» for mineral water analysis
    • Moreno L., Merlos A., Abramova N., Jimenez C., Bratov A. Multi-sensor array used as an «electronic tongue» for mineral water analysis. Sensors and Actuators B 2006 116 P. 130-134.
    • (2006) Sensors and Actuators B , vol.116 , pp. 130-134
    • Moreno, L.1    Merlos, A.2    Abramova, N.3    Jimenez, C.4    Bratov, A.5
  • 13
    • 14644434380 scopus 로고    scopus 로고
    • A multi-biosensor based on immobilized Photosystem II on screen-printed electrodes for the detection of herbicides in river water
    • Touloupakisa E., Giannoudi L., Piletsky S. A., Guzzella L., Pozzoni F., Giardi M. T. A multi-biosensor based on immobilized Photosystem II on screen-printed electrodes for the detection of herbicides in river water. Biosensors and Bioelectronics 2005 20 P. 1984-1992.
    • (2005) Biosensors and Bioelectronics , vol.20 , pp. 1984-1992
    • Touloupakisa, E.1    Giannoudi, L.2    Piletsky, S.A.3    Guzzella, L.4    Pozzoni, F.5    Giardi, M.T.6
  • 15
    • 80955165260 scopus 로고    scopus 로고
    • Biosensors based on ion-selective field effect transistors: Theory, technology, practice
    • Dzyadevych S. V. Biosensors based on ion-selective field effect transistors: theory, technology, practice. Biopolym. Cell. 2004; 20(1-2):7-16
    • (2004) Biopolym. Cell , vol.20 , Issue.1-2 , pp. 7-16
    • Dzyadevych, S.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.