메뉴 건너뛰기




Volumn 36, Issue 2, 2009, Pages 330-334

Dynamic filling index: a novel parameter to monitor circulatory filling during minimized extracorporeal bypass

Author keywords

Blood volume; Cardiopulmonary bypass; Centrifugal pump; Minimized extracorporeal bypass; Venous drainage; Venous return

Indexed keywords

ADULT; AGED; ARTICLE; ASSISTED CIRCULATION; BLOOD FLOW VELOCITY; CENTRIFUGATION; CLINICAL ARTICLE; CLINICAL TRIAL; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY BYPASS GRAFT; DYNAMIC FILLING INDEX; EXTRACORPOREAL CIRCULATION; HEART ASSIST DEVICE; HEMODYNAMIC PARAMETERS; HUMAN; OXYGENATOR; PATIENT MONITORING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; REPRODUCIBILITY; VENOUS RETURN;

EID: 67650047870     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2009.03.045     Document Type: Article
Times cited : (10)

References (19)
  • 2
    • 0036803163 scopus 로고    scopus 로고
    • Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation
    • Fromes Y., Gaillard D., Ponzio O., Chauffert M., Gerhardt M.F., Deleuze P., and Bical O.M. Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation. Eur J Cardiothorac Surg 22 (2002) 527-533
    • (2002) Eur J Cardiothorac Surg , vol.22 , pp. 527-533
    • Fromes, Y.1    Gaillard, D.2    Ponzio, O.3    Chauffert, M.4    Gerhardt, M.F.5    Deleuze, P.6    Bical, O.M.7
  • 3
    • 38349098665 scopus 로고    scopus 로고
    • Extracorporeal membrane oxygenation with a poly-methylpentene oxygenator (Quadrox D). The experience of a single Italian centre in adult patients with refractory cardiogenic shock
    • Formica F., Avalli L., Martino A., Maggioni E., Muratore M., Ferro O., Pesenti A., and Paolini G. Extracorporeal membrane oxygenation with a poly-methylpentene oxygenator (Quadrox D). The experience of a single Italian centre in adult patients with refractory cardiogenic shock. ASAIO J 54 (2008) 89-94
    • (2008) ASAIO J , vol.54 , pp. 89-94
    • Formica, F.1    Avalli, L.2    Martino, A.3    Maggioni, E.4    Muratore, M.5    Ferro, O.6    Pesenti, A.7    Paolini, G.8
  • 4
    • 0034673160 scopus 로고    scopus 로고
    • Extracorporeal life support: the University of Michigan experience
    • Bartlett R.H., Roloff D.W., Custer J.R., Younger J.G., and Hirschl R.B. Extracorporeal life support: the University of Michigan experience. JAMA 283 (2000) 904-908
    • (2000) JAMA , vol.283 , pp. 904-908
    • Bartlett, R.H.1    Roloff, D.W.2    Custer, J.R.3    Younger, J.G.4    Hirschl, R.B.5
  • 7
    • 4444333445 scopus 로고    scopus 로고
    • Mini extracorporeal circuit for coronary artery bypass grafting: initial clinical and biochemical results: a comparison with conventional and off-pump coronary artery bypass grafts concerning global oxidative stress and alveolar function
    • van Boven W.J., Gerritsen W.B., Waanders F.G., Haas F.J., and Aarts L.P. Mini extracorporeal circuit for coronary artery bypass grafting: initial clinical and biochemical results: a comparison with conventional and off-pump coronary artery bypass grafts concerning global oxidative stress and alveolar function. Perfusion 19 (2004) 239-246
    • (2004) Perfusion , vol.19 , pp. 239-246
    • van Boven, W.J.1    Gerritsen, W.B.2    Waanders, F.G.3    Haas, F.J.4    Aarts, L.P.5
  • 8
    • 10044231710 scopus 로고    scopus 로고
    • Four years' experience with a miniaturized extracorporeal circulation system and its influence on clinical outcome
    • Wiesenack C., Liebold A., Philipp A., Ritzka M., Koppenberg J., Birnbaum D.E., and Keyl C. Four years' experience with a miniaturized extracorporeal circulation system and its influence on clinical outcome. Artif Organs 28 (2004) 1082-1088
    • (2004) Artif Organs , vol.28 , pp. 1082-1088
    • Wiesenack, C.1    Liebold, A.2    Philipp, A.3    Ritzka, M.4    Koppenberg, J.5    Birnbaum, D.E.6    Keyl, C.7
  • 17
    • 0027501674 scopus 로고
    • Control of a rotary pulsatile cardiac assist pump driven by an electric motor without a pressure sensor to avoid collapse of the pump inlet
    • Trinkl J., Havlik P., Mesana T., Mitsui N., Morita S., Demunck J.L., Tourres J.L., and Monties J.R. Control of a rotary pulsatile cardiac assist pump driven by an electric motor without a pressure sensor to avoid collapse of the pump inlet. ASAIO J 39 (1993) M237-M241
    • (1993) ASAIO J , vol.39
    • Trinkl, J.1    Havlik, P.2    Mesana, T.3    Mitsui, N.4    Morita, S.5    Demunck, J.L.6    Tourres, J.L.7    Monties, J.R.8
  • 18
    • 0026690168 scopus 로고
    • Comparison of a new venous control device with a bladder box system for use in ECMO
    • Setz K., Kesser K., Kopotic R.J., and Cornish J.D. Comparison of a new venous control device with a bladder box system for use in ECMO. ASAIO J 38 (1992) 835-840
    • (1992) ASAIO J , vol.38 , pp. 835-840
    • Setz, K.1    Kesser, K.2    Kopotic, R.J.3    Cornish, J.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.