Volumn 18, Issue 3, 2009, Pages 232-239

Precision-to-tolerance capability: An important consideration in tight glucose control

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; COMMUNITY HOSPITAL; COMPARATIVE STUDY; DIAGNOSTIC ERROR; DIAGNOSTIC TEST; GLUCOSE BLOOD LEVEL; HEMATOCRIT; HOSPITAL INFORMATION SYSTEM; HUMAN; REPRODUCIBILITY; STANDARD; THORAX SURGERY; UNITED STATES;

EID: 67649782346     PISSN: 10623264     EISSN: None     Source Type: Journal    
DOI: 10.4037/ajcc2009262     Document Type: Article
Times cited : (3)

References (34)
  • 1
    • 0842307263 scopus 로고    scopus 로고
    • A critical review of blood glucose testing
    • Nichols JH. A critical review of blood glucose testing. Point Care. 2003;2(1):49-61.
    • (2003) Point Care , vol.2 , Issue.1 , pp. 49-61
    • Nichols, J.H.1
  • 2
    • 29144531185 scopus 로고    scopus 로고
    • How accurate are currently used methods of determining glycemia in critically ill patients, and do they affect their clinical course?
    • Chrousos G, Kaltsas G. How accurate are currently used methods of determining glycemia in critically ill patients, and do they affect their clinical course? Crit Care Med. 2005; 33(12):2849-2850.
    • (2005) Crit Care Med , vol.33 , Issue.12 , pp. 2849-2850
    • Chrousos, G.1    Kaltsas, G.2
  • 3
    • 33646920608 scopus 로고    scopus 로고
    • Accuracy of portable blood glucose monitors
    • Aboezz R, Miller DR. Accuracy of portable blood glucose monitors. J Am Pharm Assoc. 2005;45(4):514-516.
    • (2005) J Am Pharm Assoc , vol.45 , Issue.4 , pp. 514-516
    • Aboezz, R.1    Miller, D.R.2
  • 4
    • 34249913197 scopus 로고    scopus 로고
    • Point-of-care measurements on a neonatal intensive care unit using the OMNI-S blood gas analyzer
    • Arthurs O, Dey P, Pattnayak S, Bewley B, MacDonald A, Kelsall W. Point-of-care measurements on a neonatal intensive care unit using the OMNI-S blood gas analyzer. Point Care. 2007;6(2):112-117.
    • (2007) Point Care , vol.6 , Issue.2 , pp. 112-117
    • Arthurs, O.1    Dey, P.2    Pattnayak, S.3    Bewley, B.4    MacDonald, A.5    Kelsall, W.6
  • 5
    • 44649179643 scopus 로고    scopus 로고
    • Clinical and analytical performance of the Accu-Chek Inform point-of-care glucose meter
    • Brouwers A, Bernard D, Langlois M. Clinical and analytical performance of the Accu-Chek Inform point-of-care glucose meter. Point Care. 2005;4(1):36-40.
    • (2005) Point Care , vol.4 , Issue.1 , pp. 36-40
    • Brouwers, A.1    Bernard, D.2    Langlois, M.3
  • 6
    • 77954594421 scopus 로고    scopus 로고
    • Comparison of glucometers shows lack of harmonization among different brands of point-of-care glucose monitoring systems
    • Cesar K, Lamonica R, Rabelo R. Comparison of glucometers shows lack of harmonization among different brands of point-of-care glucose monitoring systems. Point Care. 2003;2(3):208-213.
    • (2003) Point Care , vol.2 , Issue.3 , pp. 208-213
    • Cesar, K.1    Lamonica, R.2    Rabelo, R.3
  • 7
    • 0032412333 scopus 로고    scopus 로고
    • Comparative accuracy of glucose monitors
    • Fanghänel G, Sanchez-Reyes L, Morales M, et al. Comparative accuracy of glucose monitors. Arch Med Res. 1998;29(4): 325-329.
    • (1998) Arch Med Res , vol.29 , Issue.4 , pp. 325-329
    • Fanghänel, G.1    Sanchez-Reyes, L.2    Morales, M.3
  • 8
    • 19844365140 scopus 로고    scopus 로고
    • Agreement between bedside blood and plasma glucose measurement in the ICU setting
    • Finkielman JD, Oyen LJ, Afessa B. Agreement between bedside blood and plasma glucose measurement in the ICU setting. Chest. 2005;127(5):1749-1751.
    • (2005) Chest , vol.127 , Issue.5 , pp. 1749-1751
    • Finkielman, J.D.1    Oyen, L.J.2    Afessa, B.3
  • 9
    • 0027357270 scopus 로고
    • A comparison of four glucose monitors in a hospital medical surgical setting
    • Harding K. A comparison of four glucose monitors in a hospital medical surgical setting. Clin Nurse Spec. 1993; 7(1):13-16.
    • (1993) Clin Nurse Spec , vol.7 , Issue.1 , pp. 13-16
    • Harding, K.1
  • 10
    • 3042706247 scopus 로고    scopus 로고
    • Evaluation of "point of care" devices in the measurement of low blood glucose in neonatal practice
    • Ho HT, Yeung WKY, Young BWY. Evaluation of "point of care" devices in the measurement of low blood glucose in neonatal practice. Arch Dis Child Fetal Neonatal Ed. 2003; 89:F356-F359.
    • (2003) Arch Dis Child Fetal Neonatal Ed , vol.89
    • Ho, H.T.1    Yeung, W.K.Y.2    Young, B.W.Y.3
  • 11
    • 0013317179 scopus 로고    scopus 로고
    • Multi-site performance evaluation of pH, blood gas, electrolyte, glucose, and lactate determinations with the GEM Premier 3000 critical care analyzer
    • Jacobs E, Ancy JJ, Smith M. Multi-site performance evaluation of pH, blood gas, electrolyte, glucose, and lactate determinations with the GEM Premier 3000 critical care analyzer. Point Care. 2002;1(3):135-144.
    • (2002) Point Care , vol.1 , Issue.3 , pp. 135-144
    • Jacobs, E.1    Ancy, J.J.2    Smith, M.3
  • 12
    • 12944326317 scopus 로고    scopus 로고
    • Analysis of blood glucose measurements using capillary and arterial blood samples in intensive care patients
    • Kulkarni A, Saxena M, Price G, et al. Analysis of blood glu measurements using capillary and arterial blood samples in intensive care patients. Intensive Care Med. 2005; 31(1):142-145.
    • (2005) Intensive Care Med , vol.31 , Issue.1 , pp. 142-145
    • Kulkarni, A.1    Saxena, M.2    Price, G.3
  • 13
    • 34548594005 scopus 로고    scopus 로고
    • Comparison of point-of-care and laboratory glucose analysis in critically ill patients
    • Lacara T, Domagtoy C, Lickliter D, et al. Comparison of point-of-care and laboratory glucose analysis in critically ill patients. Am J Crit Care. 2007;16(4):336-347.
    • (2007) Am J Crit Care , vol.16 , Issue.4 , pp. 336-347
    • Lacara, T.1    Domagtoy, C.2    Lickliter, D.3
  • 14
    • 0028262386 scopus 로고
    • Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: are they accurate?
    • Maser RE, Butler MA, DeCherney GS. Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: are they accurate? Crit Care Med. 1994;22(4):595-599.
    • (1994) Crit Care Med , vol.22 , Issue.4 , pp. 595-599
    • Maser, R.E.1    Butler, M.A.2    DeCherney, G.S.3
  • 15
    • 0027769056 scopus 로고
    • Capillary blood glucose measurements in hospital inpatients using portable glucose meters
    • Phillipou G, Seaborn CJ, Hooper J, Phillips PJ. Capillary blood glucose measurements in hospital inpatients using portable glucose meters. Aust N Z J Med. 1993;23(6):667-671.
    • (1993) Aust N Z J Med , vol.23 , Issue.6 , pp. 667-671
    • Phillipou, G.1    Seaborn, C.J.2    Hooper, J.3    Phillips, P.J.4
  • 17
    • 0038642315 scopus 로고    scopus 로고
    • Comparison of several point-of-care testing (POCT) glucometers with an established laboratory procedure for the diagnosis of type 2 diabetes using the discordance rate, a new statistical approach
    • Püntmann I, Wosniok W, Haeckel R. Comparison of several point-of-care testing (POCT) glucometers with an established laboratory procedure for the diagnosis of type 2 diabetes using the discordance rate, a new statistical approach. Clin Chem Lab Med. 2003;41(6):809-820.
    • (2003) Clin Chem Lab Med , vol.41 , Issue.6 , pp. 809-820
    • Püntmann, I.1    Wosniok, W.2    Haeckel, R.3
  • 18
    • 0035170340 scopus 로고    scopus 로고
    • Pilot study of the accuracy of bedside glucometry in the intensive care unit
    • Ray JG, Hamielec C, Mastracci T. Pilot study of the accuracy of bedside glucometry in the intensive care unit. Crit Care Med. 2001;29(11):2205-2207.
    • (2001) Crit Care Med , vol.29 , Issue.11 , pp. 2205-2207
    • Ray, J.G.1    Hamielec, C.2    Mastracci, T.3
  • 19
    • 77954240392 scopus 로고    scopus 로고
    • External quality assessment in the quality management of POCT
    • Richardson H, Gun-Munro J, Petersons A, Webb S. External quality assessment in the quality management of POCT. Point Care. 2005;4(4):164-166.
    • (2005) Point Care , vol.4 , Issue.4 , pp. 164-166
    • Richardson, H.1    Gun-Munro, J.2    Petersons, A.3    Webb, S.4
  • 20
    • 29144475766 scopus 로고
    • Reliability of point-of-care testing for glucose measurement in critically ill adults
    • Kanji S, Buffie J, Hutton B, et al. Reliability of point-of-care testing for glucose measurement in critically ill adults. Crit Care Med. 1995;33(12):2778-2785.
    • (1995) Crit Care Med , vol.33 , Issue.12 , pp. 2778-2785
    • Kanji, S.1    Buffie, J.2    Hutton, B.3
  • 21
    • 34248216398 scopus 로고    scopus 로고
    • Quality control of monitoring glycemia in patients with diabetes
    • Solnica B, Naskalski JW, Hebda-Szydlo A, Sieradski J. Quality control of monitoring glycemia in patients with diabetes. Point Care. 2005;4(1):45-48.
    • (2005) Point Care , vol.4 , Issue.1 , pp. 45-48
    • Solnica, B.1    Naskalski, J.W.2    Hebda-Szydlo, A.3    Sieradski, J.4
  • 22
    • 0033849382 scopus 로고    scopus 로고
    • Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing
    • Tang Z, Lee JH, Louie RF, Kost GJ. Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing. Arch Pathol Lab Med. 2000;124(8):1135-1140.
    • (2000) Arch Pathol Lab Med , vol.124 , Issue.8 , pp. 1135-1140
    • Tang, Z.1    Lee, J.H.2    Louie, R.F.3    Kost, G.J.4
  • 23
    • 0035023293 scopus 로고    scopus 로고
    • Oxygen effects on glucose meter measurements with glucose dehydrogenaseand oxidase-based test strips for point-ofcare testing
    • Tang Z, Louie RF, Lee JH, Lee DM, Miller EE, Kost GJ. Oxygen effects on glucose meter measurements with glucose dehydrogenaseand oxidase-based test strips for point-ofcare testing. Crit Care Med. 2001;29(5):1062-1070.
    • (2001) Crit Care Med , vol.29 , Issue.5 , pp. 1062-1070
    • Tang, Z.1    Louie, R.F.2    Lee, J.H.3    Lee, D.M.4    Miller, E.E.5    Kost, G.J.6
  • 24
    • 1642486752 scopus 로고    scopus 로고
    • Comparison of outpatient point of care glucose testing vs venous glucose in the clinical laboratory
    • Velázquez Medina D, Climent C. Comparison of outpatient point of care glucose testing vs venous glucose in the clinical laboratory. P R Health Sci J. 2003;22(4):385-389.
    • (2003) P R Health Sci J , vol.22 , Issue.4 , pp. 385-389
    • Velázquez Medina, D.1    Climent, C.2
  • 25
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland M, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307-310.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, M.1    Altman, D.G.2
  • 26
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland M, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8(2):135-160.
    • (1999) Stat Methods Med Res , vol.8 , Issue.2 , pp. 135-160
    • Bland, M.1    Altman, D.G.2
  • 30
  • 32
    • 0030154483 scopus 로고    scopus 로고
    • Evaluation of instrument error and method agreement
    • Chatburn RL. Evaluation of instrument error and method agreement. AANA J. 1996;64(3):261-268.
    • (1996) AANA J , vol.64 , Issue.3 , pp. 261-268
    • Chatburn, R.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.