Volumn 6, Issue 2, 2007, Pages 112-117

Point-of-care measurements on a neonatal intensive care unit using the OMNI-S blood gas analyzer

Author keywords

Bilirubin; Glucose; Hematocrit; OMNI S; Potassium; Sodium

Indexed keywords


EID: 34249913197     PISSN: 1533029X     EISSN: 15330303     Source Type: Journal    
DOI: 10.1097/01.poc.0000271405.60677.8d     Document Type: Article
Times cited : (4)

References (12)
  • 1
    • 0033946486 scopus 로고    scopus 로고
    • Multiple site analytical evaluation of a portable blood gas/electrolyte analyzer for patient of care testing
    • Chance JJ, Li DJ, Sokoll LJ, et al. Multiple site analytical evaluation of a portable blood gas/electrolyte analyzer for patient of care testing. Crit Care Med. 2000;28:2081-2085.
    • (2000) Crit Care Med , vol.28 , pp. 2081-2085
    • Chance, J.J.1    Li, D.J.2    Sokoll, L.J.3
  • 2
    • 0037334724 scopus 로고    scopus 로고
    • Comparison of lactate, bilirubin and hemoglobin F concentrations obtained by the ABL 700 series blood gas analyzers with laboratory methods
    • Suen WW, Ridley B, Blakney G, et al. Comparison of lactate, bilirubin and hemoglobin F concentrations obtained by the ABL 700 series blood gas analyzers with laboratory methods. Clin Biochem. 2003;36:103-107.
    • (2003) Clin Biochem , vol.36 , pp. 103-107
    • Suen, W.W.1    Ridley, B.2    Blakney, G.3
  • 3
    • 0027410804 scopus 로고
    • Evaluation of a novel point-of-care system, the I-STAT portable clinical analyser
    • Erickson KA, Wilding P. Evaluation of a novel point-of-care system, the I-STAT portable clinical analyser. Clin Chem. 1993;39:283-287.
    • (1993) Clin Chem , vol.39 , pp. 283-287
    • Erickson, K.A.1    Wilding, P.2
  • 4
    • 0034842834 scopus 로고    scopus 로고
    • Bilirubin measured on a blood gas analyser: A suitable alternative for near patient assessment of neonatal jaundice
    • Peake M, Mazzachi B, Fudge A, et al. Bilirubin measured on a blood gas analyser: a suitable alternative for near patient assessment of neonatal jaundice. Ann Clin Biochem. 2001;38:535-540.
    • (2001) Ann Clin Biochem , vol.38 , pp. 535-540
    • Peake, M.1    Mazzachi, B.2    Fudge, A.3
  • 5
    • 0034820216 scopus 로고    scopus 로고
    • Total bilirubin measurement by photometry on blood gas analyzer: Potential for use in neonatal testing at point of care
    • Rolinski B, Kuster H, Ugele B, et al. Total bilirubin measurement by photometry on blood gas analyzer: potential for use in neonatal testing at point of care. Clin Chem. 2001;47:1845-1847.
    • (2001) Clin Chem , vol.47 , pp. 1845-1847
    • Rolinski, B.1    Kuster, H.2    Ugele, B.3
  • 6
    • 0036065153 scopus 로고    scopus 로고
    • Accurate direct spectrophotometric bilirubin measurement combined with blood gas analysis
    • Laterza OF, Smith CH, Wilhite TR, et al. Accurate direct spectrophotometric bilirubin measurement combined with blood gas analysis. Clin Chim Acta. 2002;323:115-120.
    • (2002) Clin Chim Acta , vol.323 , pp. 115-120
    • Laterza, O.F.1    Smith, C.H.2    Wilhite, T.R.3
  • 7
    • 0029401681 scopus 로고
    • Current nursing practice of point of care laboratory diagnostic testing in critical care units
    • Lamb LS, Parish RS, Goran SF, et al. Current nursing practice of point of care laboratory diagnostic testing in critical care units. Am J Crit Care. 1995;4:429-434.
    • (1995) Am J Crit Care , vol.4 , pp. 429-434
    • Lamb, L.S.1    Parish, R.S.2    Goran, S.F.3
  • 8
    • 34249904880 scopus 로고    scopus 로고
    • Multicenter study on the analytic performance of a new point of care blood gas analyzer and its use in critical testing
    • Bewley B, Creed G, Goerlach-Graw A, et al. Multicenter study on the analytic performance of a new point of care blood gas analyzer and its use in critical testing. Point Care. 2004;4:149-155.
    • (2004) Point Care , vol.4 , pp. 149-155
    • Bewley, B.1    Creed, G.2    Goerlach-Graw, A.3
  • 9
    • 33746633638 scopus 로고    scopus 로고
    • Evaluation of total bilirubin determination in neonatal whole blood samples by multiwavelength photometry on the Roche OMNI-S point of care analyzer
    • Rolinski B, Okorodudu AO, Kost G, et al. Evaluation of total bilirubin determination in neonatal whole blood samples by multiwavelength photometry on the Roche OMNI-S point of care analyzer. Point of Care. 2005;4:3-8.
    • (2005) Point of Care , vol.4 , pp. 3-8
    • Rolinski, B.1    Okorodudu, A.O.2    Kost, G.3
  • 10
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part I
    • Passing H, Bablok WA. A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part I. J Clin Chem Clin Biochem. 1983;21:709-720.
    • (1983) J Clin Chem Clin Biochem , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.A.2
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing the agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing the agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0034243250 scopus 로고    scopus 로고
    • Non-invasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia
    • Bhutani VK, Gourley GR, Adler S, et al. Non-invasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia. Pediatrics. 2000;106:17.
    • (2000) Pediatrics , vol.106 , pp. 17
    • Bhutani, V.K.1    Gourley, G.R.2    Adler, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.