Volumn 36, Issue 7, 2009, Pages 3205-3210

Field size dependence of the output factor in passively scattered proton therapy: Influence of range, modulation, air gap, and machine settings

Author keywords

Calibration; Dosimetry; Proton therapy; Small fields

Indexed keywords

CALIBRATION; CHARGED PARTICLES; DOSIMETRY; MODULATION; PROTON BEAMS;

EID: 67649616537     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3152111     Document Type: Article
Times cited : (31)

References (9)
  • 1
    • 29144513071 scopus 로고    scopus 로고
    • The prediction of output factors for spread-out proton Bragg peak fields in clinical practice
    • 0031-9155,. 10.1088/0031-9155/50/24/006
    • H. M. Kooy, S. J. Rosenthal, M. Engelsman, A. Mazal, R. L. Slopsema, H. Paganetti, and J. B. Flanz, " The prediction of output factors for spread-out proton Bragg peak fields in clinical practice.," Phys. Med. Biol. 0031-9155 50, 5847-5856 (2005). 10.1088/0031-9155/50/24/006
    • (2005) Phys. Med. Biol. , vol.50 , pp. 5847-5856
    • Kooy, H.M.1    Rosenthal, S.J.2    Engelsman, M.3    Mazal, A.4    Slopsema, R.L.5    Paganetti, H.6    Flanz, J.B.7
  • 2
    • 66449134494 scopus 로고    scopus 로고
    • Commissioning a passive-scattering proton therapy nozzle for accurate SOBP delivery
    • 10.1118/1.3121489
    • M. Engelsman, H. -M. Lu, D. Herrup, M. Bussìre, and H. M. Kooy " Commissioning a passive-scattering proton therapy nozzle for accurate SOBP delivery.," Med. Phys 36, 2172-2180 (2009). 10.1118/1.3121489
    • (2009) Med. Phys , vol.36 , pp. 2172-2180
    • Engelsman, M.1    Lu, H.-M.2    Herrup, D.3    Bussìre, M.4    Kooy, H.M.5
  • 3
    • 33846634593 scopus 로고    scopus 로고
    • Determination of output factors for small proton therapy fields
    • 0094-2405,. 10.1118/1.2428406
    • J. D. Fontenot, W. D. Newhauser, C. Bloch, R. A. White, U. Titt, and G. Starkschall, " Determination of output factors for small proton therapy fields.," Med. Phys. 0094-2405 34, 489-498 (2007). 10.1118/1.2428406
    • (2007) Med. Phys. , vol.34 , pp. 489-498
    • Fontenot, J.D.1    Newhauser, W.D.2    Bloch, C.3    White, R.A.4    Titt, U.5    Starkschall, G.6
  • 5
    • 38049178648 scopus 로고    scopus 로고
    • Monte Carlo investigation of collimator scatter of proton-therapy beams produced using the passive scattering method
    • 0031-9155,. 10.1088/0031-9155/53/2/014
    • U. Titt, Y. Zheng, O. N. Vassiliev, and W. D. Newhauser, " Monte Carlo investigation of collimator scatter of proton-therapy beams produced using the passive scattering method.," Phys. Med. Biol. 0031-9155 53, 487-504 (2008). 10.1088/0031-9155/53/2/014
    • (2008) Phys. Med. Biol. , vol.53 , pp. 487-504
    • Titt, U.1    Zheng, Y.2    Vassiliev, O.N.3    Newhauser, W.D.4
  • 6
    • 0035106516 scopus 로고    scopus 로고
    • Collimator scatter and 2D dosimetry in small proton beams
    • 0031-9155,. 10.1088/0031-9155/46/3/303
    • P. van Luijk, A. A. van t' Veld, H. D. Zelle, and J. M. Schippers, " Collimator scatter and 2D dosimetry in small proton beams.," Phys. Med. Biol. 0031-9155 46, 653-670 (2001). 10.1088/0031-9155/46/3/303
    • (2001) Phys. Med. Biol. , vol.46 , pp. 653-670
    • Van Luijk, P.1    Van T Veld, A.A.2    Zelle, H.D.3    Schippers, J.M.4
  • 7
    • 85027231387 scopus 로고    scopus 로고
    • B. Gottschalk, http://huhepl.harvard.edu/~gottschalk.
    • Gottschalk, B.1
  • 8
    • 47649123733 scopus 로고    scopus 로고
    • Parameterization and application of scatter kernels for modeling scanned proton beam collimator scatter dose
    • 0031-9155,. 10.1088/0031-9155/53/13/001
    • P. Kimstrand, E. Traneus, A. Ahnesjö, and N. Tilly, " Parameterization and application of scatter kernels for modeling scanned proton beam collimator scatter dose.," Phys. Med. Biol. 0031-9155 53, 3405-3429 (2008). 10.1088/0031-9155/53/13/001
    • (2008) Phys. Med. Biol. , vol.53 , pp. 3405-3429
    • Kimstrand, P.1    Traneus, E.2    Ahnesjö, A.3    Tilly, N.4
  • 9
    • 54949115914 scopus 로고    scopus 로고
    • A procedure for calculation of monitor units for passively scattered proton radiotherapy beams
    • 0094-2405,. 10.1118/1.2992055
    • N. Sahoo, X. R. Zhu, B. Arjomandy, G. Ciangaru, M. Lij, R. Amos, R. Wu, and M. T. Gillin, " A procedure for calculation of monitor units for passively scattered proton radiotherapy beams.," Med. Phys. 0094-2405 35, 5088-5097 (2008). 10.1118/1.2992055
    • (2008) Med. Phys. , vol.35 , pp. 5088-5097
    • Sahoo, N.1    Zhu, X.R.2    Arjomandy, B.3    Ciangaru, G.4    Lij, M.5    Amos, R.6    Wu, R.7    Gillin, M.T.8