메뉴 건너뛰기




Volumn 39, Issue 8, 2009, Pages 707-712

Influence of pulse pressure variation on the results of local arterial compliance measurement: A computer simulation study

Author keywords

Arterial compliance; Computer simulation; Langewouters model; Modeling; Pressure area relationship; Pressure volume relationship; Pulse pressure variation

Indexed keywords

ARTERIAL COMPLIANCE; LANGEWOUTERS MODEL; MODELING; PRESSURE-AREA RELATIONSHIP; PULSE PRESSURE VARIATION;

EID: 67649610683     PISSN: 00104825     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compbiomed.2009.05.003     Document Type: Article
Times cited : (4)

References (29)
  • 1
    • 0036190775 scopus 로고    scopus 로고
    • Assessment of arterial stiffness in clinical practice
    • Mackenzie I.S., Wilkinson I.B., and Cockcroft J.R. Assessment of arterial stiffness in clinical practice. Q. J. Med. 95 (2002) 67-74
    • (2002) Q. J. Med. , vol.95 , pp. 67-74
    • Mackenzie, I.S.1    Wilkinson, I.B.2    Cockcroft, J.R.3
  • 3
    • 0021925483 scopus 로고
    • Non-invasive measurement of beat-to-beat vascular viscoelastic properties in human fingers and forearms
    • Shimazu H., Fukuoka M., Ito H., and Yamakoshi K. Non-invasive measurement of beat-to-beat vascular viscoelastic properties in human fingers and forearms. Med. Biol. Eng. Comput. 23 1 (1985) 43-47
    • (1985) Med. Biol. Eng. Comput. , vol.23 , Issue.1 , pp. 43-47
    • Shimazu, H.1    Fukuoka, M.2    Ito, H.3    Yamakoshi, K.4
  • 4
    • 0036934675 scopus 로고    scopus 로고
    • Finger arterial compliance as determined by transmission of light during mental stress and reactive hyperaemia
    • Tanaka G., Sawada Y., Matsumura K., Nagano Y., and Yamakoshi K. Finger arterial compliance as determined by transmission of light during mental stress and reactive hyperaemia. Eur. J. Appl. Physiol. 87 6 (2002) 562-567
    • (2002) Eur. J. Appl. Physiol. , vol.87 , Issue.6 , pp. 562-567
    • Tanaka, G.1    Sawada, Y.2    Matsumura, K.3    Nagano, Y.4    Yamakoshi, K.5
  • 6
    • 0033529385 scopus 로고    scopus 로고
    • In vivo human brachial artery elastic mechanics: effects of smooth muscle relaxation
    • Bank A.J., Kaiser D.R., Rajala S., and Cheng A. In vivo human brachial artery elastic mechanics: effects of smooth muscle relaxation. Circulation 100 (1999) 41-47
    • (1999) Circulation , vol.100 , pp. 41-47
    • Bank, A.J.1    Kaiser, D.R.2    Rajala, S.3    Cheng, A.4
  • 9
    • 38149075824 scopus 로고    scopus 로고
    • Application of delta-based and derivative-based algorithms to determine beat-to-beat finger arterial compliance during handgrip exercise
    • Raamat R., Talts J., and Jagomägi K. Application of delta-based and derivative-based algorithms to determine beat-to-beat finger arterial compliance during handgrip exercise. Med. Eng. Phys. 30 (2008) 67-74
    • (2008) Med. Eng. Phys. , vol.30 , pp. 67-74
    • Raamat, R.1    Talts, J.2    Jagomägi, K.3
  • 10
    • 0031148823 scopus 로고    scopus 로고
    • Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure
    • Baker P.D., Westenskow D.R., and Kück K. Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure. Med. Biol. Eng. Comput. 35 (1997) 271-278
    • (1997) Med. Biol. Eng. Comput. , vol.35 , pp. 271-278
    • Baker, P.D.1    Westenskow, D.R.2    Kück, K.3
  • 11
    • 38049034302 scopus 로고    scopus 로고
    • Identification of the dynamic component of the finger arterial pressure-volume relationship
    • WIT Press, Southampton
    • Talts J., Raamat R., and Jagomägi K. Identification of the dynamic component of the finger arterial pressure-volume relationship. Modelling in Medicine and Biology vol. VI (2005), WIT Press, Southampton 153-160
    • (2005) Modelling in Medicine and Biology , vol.VI , pp. 153-160
    • Talts, J.1    Raamat, R.2    Jagomägi, K.3
  • 12
    • 33748516143 scopus 로고    scopus 로고
    • Asymmetric time-dependent model for the dynamic finger arterial pressure-volume relationship
    • Talts J., Raamat R., and Jagomägi K. Asymmetric time-dependent model for the dynamic finger arterial pressure-volume relationship. Med. Biol. Eng. Comput. 44 (2006) 829-834
    • (2006) Med. Biol. Eng. Comput. , vol.44 , pp. 829-834
    • Talts, J.1    Raamat, R.2    Jagomägi, K.3
  • 13
    • 0030701936 scopus 로고    scopus 로고
    • Vessel growth and collapsible pressure-area relationship
    • Drzewiecki G., Field S., Moubarak I., and Li J.K. Vessel growth and collapsible pressure-area relationship. Am. J. Physiol. 273 (1997) H2030-H2043
    • (1997) Am. J. Physiol. , vol.273
    • Drzewiecki, G.1    Field, S.2    Moubarak, I.3    Li, J.K.4
  • 14
    • 0021249532 scopus 로고
    • The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model
    • Langewouters G.J., Wesseling K.H., and Goedhard W.J. The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model. J. Biomech. 17 (1984) 425-435
    • (1984) J. Biomech. , vol.17 , pp. 425-435
    • Langewouters, G.J.1    Wesseling, K.H.2    Goedhard, W.J.3
  • 15
    • 35348981846 scopus 로고    scopus 로고
    • Calibrated photoplethysmographic estimation of digital pulse volume and arterial compliance
    • Raamat R., Jagomagi K., and Talts J. Calibrated photoplethysmographic estimation of digital pulse volume and arterial compliance. Clin. Physiol. Funct. Imaging (2007) 354-362
    • (2007) Clin. Physiol. Funct. Imaging , pp. 354-362
    • Raamat, R.1    Jagomagi, K.2    Talts, J.3
  • 18
    • 0029793273 scopus 로고    scopus 로고
    • Continuous non-invasive measurement of mean blood pressure in fingers by volume-clamp and differential oscillometric method
    • Jagomägi K., Talts J., Raamat R., and Länsimies E. Continuous non-invasive measurement of mean blood pressure in fingers by volume-clamp and differential oscillometric method. Clin. Physiol. 16 (1996) 551-560
    • (1996) Clin. Physiol. , vol.16 , pp. 551-560
    • Jagomägi, K.1    Talts, J.2    Raamat, R.3    Länsimies, E.4
  • 19
    • 0033797963 scopus 로고    scopus 로고
    • Different responses of Finapres and the oscillometric finger blood pressure monitor during intensive vasomotion
    • Raamat R., Jagomägi K., and Talts J. Different responses of Finapres and the oscillometric finger blood pressure monitor during intensive vasomotion. J. Med. Eng. Technol. 24 3 (2000) 95-101
    • (2000) J. Med. Eng. Technol. , vol.24 , Issue.3 , pp. 95-101
    • Raamat, R.1    Jagomägi, K.2    Talts, J.3
  • 20
  • 21
    • 33745259283 scopus 로고    scopus 로고
    • Simultaneous application of differential servo-oscillometry and volume-clamp plethysmography for continuous non-invasive recording of the finger blood pressure response to a hand postural change
    • Raamat R., Talts J., Jagomägi K., Kivastik J., Länsimies E., and Jurvelin J. Simultaneous application of differential servo-oscillometry and volume-clamp plethysmography for continuous non-invasive recording of the finger blood pressure response to a hand postural change. J. Med. Eng. Technol. 30 3 (2006) 139-144
    • (2006) J. Med. Eng. Technol. , vol.30 , Issue.3 , pp. 139-144
    • Raamat, R.1    Talts, J.2    Jagomägi, K.3    Kivastik, J.4    Länsimies, E.5    Jurvelin, J.6
  • 22
    • 0032196779 scopus 로고    scopus 로고
    • Non-invasive measurement of the human brachial artery pressure-area relation in collapse and hypertension
    • Drzewiecki G., and Pilla J.J. Non-invasive measurement of the human brachial artery pressure-area relation in collapse and hypertension. Ann. Biomed. Eng. 26 6 (1998) 965-974
    • (1998) Ann. Biomed. Eng. , vol.26 , Issue.6 , pp. 965-974
    • Drzewiecki, G.1    Pilla, J.J.2
  • 23
  • 24
    • 18144366935 scopus 로고    scopus 로고
    • Echocardiographic assessment of aortic elastic properties with automated border detection in an ICU: in vivo application of the arctangent Langewouters model
    • Heerman J.R., Segers P., Roosens C.D., Gasthuys F., Verdonck P.R., and Poelaert J.I. Echocardiographic assessment of aortic elastic properties with automated border detection in an ICU: in vivo application of the arctangent Langewouters model. Am. J. Physiol. Heart. Circ. Physiol. (2005) H2504-H2511
    • (2005) Am. J. Physiol. Heart. Circ. Physiol.
    • Heerman, J.R.1    Segers, P.2    Roosens, C.D.3    Gasthuys, F.4    Verdonck, P.R.5    Poelaert, J.I.6
  • 25
    • 2442599564 scopus 로고    scopus 로고
    • HEART: an automated beat-to-beat cardiovascular analysis package using Matlab
    • Schroeder M.J., Perreault B., Ewert D.L., and Koenig S.C. HEART: an automated beat-to-beat cardiovascular analysis package using Matlab. Comput. Biol. Med. (2004) 371-388
    • (2004) Comput. Biol. Med. , pp. 371-388
    • Schroeder, M.J.1    Perreault, B.2    Ewert, D.L.3    Koenig, S.C.4
  • 26
    • 57649208123 scopus 로고    scopus 로고
    • Theoretical comparison between the model-based and amplitude-based compliance estimation techniques
    • Talts J., Raamat R., Jagomagi K., and Kivastik J. Theoretical comparison between the model-based and amplitude-based compliance estimation techniques. Conf. Proc. IEEE Eng. Med. Biol. Soc. 1 (2007) 549-552
    • (2007) Conf. Proc. IEEE Eng. Med. Biol. Soc. , vol.1 , pp. 549-552
    • Talts, J.1    Raamat, R.2    Jagomagi, K.3    Kivastik, J.4
  • 28
    • 0033380498 scopus 로고    scopus 로고
    • Mathematical modelling of non-invasive oscillometric finger mean blood pressure measurement by maximum oscillation criterion
    • Raamat R., Talts J., Jagomägi K., and Länsimies E. Mathematical modelling of non-invasive oscillometric finger mean blood pressure measurement by maximum oscillation criterion. Med. Biol. Eng. Comput. 37 (1999) 784-788
    • (1999) Med. Biol. Eng. Comput. , vol.37 , pp. 784-788
    • Raamat, R.1    Talts, J.2    Jagomägi, K.3    Länsimies, E.4
  • 29
    • 0024344783 scopus 로고
    • Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing
    • Parati G., Casadei R., Groppelli A., Di Rienzo M., and Mancia G. Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing. Hypertension 13 6 Pt 1 (1989) 647-655
    • (1989) Hypertension , vol.13 , Issue.6 PART 1 , pp. 647-655
    • Parati, G.1    Casadei, R.2    Groppelli, A.3    Di Rienzo, M.4    Mancia, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.