메뉴 건너뛰기




Volumn 87, Issue 6, 2002, Pages 562-567

Finger arterial compliance as determined by transmission of light during mental stress and reactive hyperaemia

Author keywords

Compliance; Distensiblity; Finger photoplethysmogram; Mental stress; Reactive hyperaemia

Indexed keywords

ADULT; ARITHMETIC; ARTERY COMPLIANCE; ARTICLE; BLOOD PRESSURE MEASUREMENT; BLOOD VESSEL TONE; CONTROLLED STUDY; CUFF; DATA ANALYSIS; DIGITAL ARTERY; FEMALE; FINGER BLOOD FLOW; HUMAN; HUMAN EXPERIMENT; HYPEREMIA; ISCHEMIA; LIGHT; MEAN ARTERIAL PRESSURE; MENTAL STRESS; NORMAL HUMAN; PHOTOELECTRIC PLETHYSMOGRAPHY; PRIORITY JOURNAL; PULSE RATE; SPECTRAL SENSITIVITY;

EID: 0036934675     PISSN: 14396319     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00421-002-0665-6     Document Type: Article
Times cited : (19)

References (26)
  • 1
    • 0029076137 scopus 로고
    • Hemoconcentration and stress: A review of physiological mechanisms and relevance for cardiovascular disease risk
    • Allen MT, Patterson SM (1995) Hemoconcentration and stress: a review of physiological mechanisms and relevance for cardiovascular disease risk. Biol Psychol 41:1-27
    • (1995) Biol. Psychol. , vol.41 , pp. 1-27
    • Allen, M.T.1    Patterson, S.M.2
  • 2
    • 0025788861 scopus 로고
    • Pressure-volume relationships of finger arteries in healthy subjects and patients with coronary atherosclerosis measured noninvasively by photoelectric plethysmography
    • Ando J, Kawarada A, Shibata M, Yamakoshi K, Kamiya A (1991) Pressure-volume relationships of finger arteries in healthy subjects and patients with coronary atherosclerosis measured noninvasively by photoelectric plethysmography. Jpn Circ J 55:567-575
    • (1991) Jpn. Circ. J. , vol.55 , pp. 567-575
    • Ando, J.1    Kawarada, A.2    Shibata, M.3    Yamakoshi, K.4    Kamiya, A.5
  • 3
    • 0029084661 scopus 로고
    • Compliance of the digital artery is decreased in patients with essential hypertension
    • Bochmann RP, Reuter U, List A, Grundig M, Sinz V (1995) Compliance of the digital artery is decreased in patients with essential hypertension. J Hum Hypertens 9:627-631
    • (1995) J. Hum. Hypertens. , vol.9 , pp. 627-631
    • Bochmann, R.P.1    Reuter, U.2    List, A.3    Grundig, M.4    Sinz, V.5
  • 8
    • 0023584464 scopus 로고
    • Photoplethysmographic assessment of digital arterial compliance in the diagnosis and treatment of hypertension
    • Jespersen LT, Krusell LR, Lederballe O (1987) Photoplethysmographic assessment of digital arterial compliance in the diagnosis and treatment of hypertension. J Clin Hypertens 3:368-376
    • (1987) J. Clin. Hypertens. , vol.3 , pp. 368-376
    • Jespersen, L.T.1    Krusell, L.R.2    Lederballe, O.3
  • 9
    • 0031650067 scopus 로고    scopus 로고
    • Endurance exercise training increases peripheral vascular response in human fingers
    • Katayama K, Shimoda M, Maeda J, Takemiya T (1998) Endurance exercise training increases peripheral vascular response in human fingers. Jpn J Physiol 48:365-371
    • (1998) Jpn. J. Physiol. , vol.48 , pp. 365-371
    • Katayama, K.1    Shimoda, M.2    Maeda, J.3    Takemiya, T.4
  • 10
    • 0022818294 scopus 로고
    • Noninvasive automatic measurement of arterial elasticity in human fingers and rabbit forelegs using photoelectric plethysmography
    • Kawarada A, Shimazu H, Yamakoshi K, Kamiya A (1986) Noninvasive automatic measurement of arterial elasticity in human fingers and rabbit forelegs using photoelectric plethysmography. Med Biol Eng Comput 24:591-596
    • (1986) Med. Biol. Eng. Comput. , vol.24 , pp. 591-596
    • Kawarada, A.1    Shimazu, H.2    Yamakoshi, K.3    Kamiya, A.4
  • 11
    • 0032211060 scopus 로고    scopus 로고
    • Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method
    • Lopez-Beltran EA, Blackshear PL, Finkelstein SM, Cohn JN (1998) Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method. Med Biol Eng Comput 36:748-753
    • (1998) Med. Biol. Eng. Comput. , vol.36 , pp. 748-753
    • Lopez-Beltran, E.A.1    Blackshear, P.L.2    Finkelstein, S.M.3    Cohn, J.N.4
  • 12
    • 0033630653 scopus 로고    scopus 로고
    • Non-invasive beat-to-beat determination of changes in the small artery compliance after smoking
    • Marc O, Potocnik N, Starc V (2000) Non-invasive beat-to-beat determination of changes in the small artery compliance after smoking. Pflügers Arch 439:R211-R212
    • (2000) Pflügers Arch. , vol.439
    • Marc, O.1    Potocnik, N.2    Starc, V.3
  • 14
    • 77049220405 scopus 로고
    • Reactive hyperaemia in the human forearm
    • Patterson GC, Whelan RF (1955) Reactive hyperaemia in the human forearm. Clin Sci 14:197-211
    • (1955) Clin. Sci. , vol.14 , pp. 197-211
    • Patterson, G.C.1    Whelan, R.F.2
  • 15
    • 0035109920 scopus 로고    scopus 로고
    • Normalized pulse volume (NPV) derived photo-plethysmographically as a more valid measure of the finger vascular tone
    • Sawada Y, Tanaka G, Yamakoshi K (2001) Normalized pulse volume (NPV) derived photo-plethysmographically as a more valid measure of the finger vascular tone. Int J Psychophysiol 41:1-10
    • (2001) Int. J. Psychophysiol. , vol.41 , pp. 1-10
    • Sawada, Y.1    Tanaka, G.2    Yamakoshi, K.3
  • 16
    • 0031194504 scopus 로고    scopus 로고
    • Arterial-pulse oximetry loops: A new method of monitoring vascular tone
    • Shelley KH, Murray WB, Chang D (1997) Arterial-pulse oximetry loops: a new method of monitoring vascular tone. J Clin Monit 13:223-228
    • (1997) J. Clin. Monit. , vol.13 , pp. 223-228
    • Shelley, K.H.1    Murray, W.B.2    Chang, D.3
  • 17
    • 0022765177 scopus 로고
    • Noninvasive measurement of the volume elastic modulus in finger arteries using photoelectric plethysmography
    • Shimazu H, Yamakoshi K, Kamiya A (1986) Noninvasive measurement of the volume elastic modulus in finger arteries using photoelectric plethysmography. IEEE Trans Biomed Eng 33:795-798
    • (1986) IEEE Trans. Biomed. Eng. , vol.33 , pp. 795-798
    • Shimazu, H.1    Yamakoshi, K.2    Kamiya, A.3
  • 19
    • 0028191047 scopus 로고
    • Analysis of microvascular responses in the finger to changes in arm position during cold water stimulation
    • Suzuki J, Maeda J, Takemiya T (1994) Analysis of microvascular responses in the finger to changes in arm position during cold water stimulation. Jpn J Physiol 44:181-191
    • (1994) Jpn. J. Physiol. , vol.44 , pp. 181-191
    • Suzuki, J.1    Maeda, J.2    Takemiya, T.3
  • 20
    • 0033989240 scopus 로고    scopus 로고
    • Beat-by-beat double-normalized pulse volume derived photoplethysmographically as a new quantitative index of finger vascular tone in humans
    • Tanaka G, Sawada Y, Yamakoshi K (2000) Beat-by-beat double-normalized pulse volume derived photoplethysmographically as a new quantitative index of finger vascular tone in humans. Eur J Appl Physiol 81:148-154
    • (2000) Eur. J. Appl. Physiol. , vol.81 , pp. 148-154
    • Tanaka, G.1    Sawada, Y.2    Yamakoshi, K.3
  • 21
    • 0012417130 scopus 로고    scopus 로고
    • Finger arterial compliance, rather than normalized pulse volume, could be more valid index of the finger vascular tone
    • Tanaka G, Sawada Y, Nagano Y, Yamakoshi K (2001) Finger arterial compliance, rather than normalized pulse volume, could be more valid index of the finger vascular tone. Psychophysiology 38 [Suppl 1]:S94
    • (2001) Psychophysiology , vol.38 , Issue.SUPPL. 1
    • Tanaka, G.1    Sawada, Y.2    Nagano, Y.3    Yamakoshi, K.4
  • 22
    • 0036246527 scopus 로고    scopus 로고
    • Evaluation of pre-operative anxiety and propofol-induced sedation using newly proposed indices of finger vascular tone
    • Tanaka G, Kawana S, Sawada Y, Yamakoshi K (2002) Evaluation of pre-operative anxiety and propofol-induced sedation using newly proposed indices of finger vascular tone. Jpn Psychol Res 44:91-98
    • (2002) Jpn. Psychol. Res. , vol.44 , pp. 91-98
    • Tanaka, G.1    Kawana, S.2    Sawada, Y.3    Yamakoshi, K.4
  • 23
    • 0026114657 scopus 로고
    • Noninvasive estimate of the mechanical properties of peripheral arteries from ultrasonic and photoplethysmographic measurements
    • Tardy Y, Meister JJ, Perret F, Brunner HR, Arditi M (1991) Noninvasive estimate of the mechanical properties of peripheral arteries from ultrasonic and photoplethysmographic measurements. Clin Phys Physiol Meas 12:39-54
    • (1991) Clin. Phys. Physiol. Meas. , vol.12 , pp. 39-54
    • Tardy, Y.1    Meister, J.J.2    Perret, F.3    Brunner, H.R.4    Arditi, M.5
  • 24
    • 0004024169 scopus 로고
    • Spectrophotometry of haemoblogin derivatives
    • Royal Vangorcum, Assen
    • Van Assendelft OW (1970) Spectrophotometry of haemoblogin derivatives. Royal Vangorcum, Assen, pp 47-73
    • (1970) , pp. 47-73
    • Van Assendelft, O.W.1
  • 25
    • 0023634623 scopus 로고
    • Noninvasive measurement of arterial blood pressure and elastic properties using photoelectric plethysmography technique
    • Yamakoshi K, Kamiya A (1987) Noninvasive measurement of arterial blood pressure and elastic properties using photoelectric plethysmography technique. Med Prog Technol 12:123-143
    • (1987) Med. Prog. Technol. , vol.12 , pp. 123-143
    • Yamakoshi, K.1    Kamiya, A.2
  • 26
    • 0020137641 scopus 로고
    • New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 1: Model experiment
    • Yamakoshi K, Shimazu H, Shibata M, Kamiya A (1982) New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 1: model experiment. Med Biol Eng Comput 20:307-313
    • (1982) Med. Biol. Eng. Comput. , vol.20 , pp. 307-313
    • Yamakoshi, K.1    Shimazu, H.2    Shibata, M.3    Kamiya, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.