메뉴 건너뛰기




Volumn 606, Issue 3, 2009, Pages 755-761

Design consideration of a multipinhole collimator with septa for ultra high-resolution silicon drift detector modules

Author keywords

Monte Carlo simulation; Multipinhole collimator; Silicon drift detector; SPECT

Indexed keywords

ANGULAR SAMPLING; CARDIAC SPECT; DESIGN CONSIDERATIONS; DETECTOR CONFIGURATION; DETECTOR MODULE; FOCAL LENGTHS; HIGH RESOLUTION; IMAGING FIELDS; INTRINSIC RESOLUTION; LOW ENERGY HIGH RESOLUTIONS; MATHEMATICAL CARDIAC TORSOS; MAXIMUM-LIKELIHOOD EXPECTATION MAXIMIZATIONS; MONTE CARLO SIMULATION; MULTI-PINHOLE COLLIMATORS; MULTIPINHOLE; MULTIPINHOLE COLLIMATOR; NOVEL DESIGN; PARALLAX ERROR; PENETRATION RATIO; PHANTOM STUDIES; RECONSTRUCTED IMAGE; SILICON DRIFT DETECTOR; SIMULATION RESULT; SPECT; SUBMILLIMETER; SYSTEM RESOLUTION; SYSTEM SENSITIVITY; ULTRA-HIGH;

EID: 67649435524     PISSN: 01689002     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nima.2009.05.019     Document Type: Article
Times cited : (10)

References (35)