메뉴 건너뛰기




Volumn 52, Issue 5 I, 2005, Pages 1359-1364

Comparison of penetration and scatter effects on defect contrast for GE and siemens LEHR collimators in myocardial perfusion SPECT - A simulation study

Author keywords

Collimator detector response; Collimator penetration

Indexed keywords

COLLIMATOR DETECTOR RESPONSE; COLLIMATOR RESPONSE; DEFECT CONTRAST; DETECTION EFFICIENCY;

EID: 29144451010     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2005.858224     Document Type: Article
Times cited : (11)

References (14)
  • 1
    • 0029861278 scopus 로고    scopus 로고
    • Influence of collimator characteristics on quantification in SPECT
    • J. S. Fleming and A. S. Alaamer, "Influence of collimator characteristics on quantification in SPECT," J. Nucl. Med., vol. 37, pp. 1832-1836, 1996.
    • (1996) J. Nucl. Med. , vol.37 , pp. 1832-1836
    • Fleming, J.S.1    Alaamer, A.S.2
  • 2
    • 0019136137 scopus 로고
    • The geometric transfer function component for scintillation camera collimators with straight parallel holes
    • C. E. Metz, F. B. Atkins, and R. N. Beck, "The geometric transfer function component for scintillation camera collimators with straight parallel holes," Phys. Med. Biol. vol. 25, pp. 1059-1070, 1980.
    • (1980) Phys. Med. Biol. , vol.25 , pp. 1059-1070
    • Metz, C.E.1    Atkins, F.B.2    Beck, R.N.3
  • 3
    • 0015684711 scopus 로고
    • Septal penetration in scintillation camera collimators
    • G. Muehllehner and H. Luig, "Septal penetration in scintillation camera collimators," Phys. Med. Biol., vol. 18, pp. 855-862, 1973.
    • (1973) Phys. Med. Biol. , vol.18 , pp. 855-862
    • Muehllehner, G.1    Luig, H.2
  • 4
    • 0019450460 scopus 로고
    • "The influence of penetrating radiation on collimator performance
    • M. J. Jahns, "The influence of penetrating radiation on collimator performance." Phys. Med. Biol., vol. 26, pp. 113-124, 1981.
    • (1981) Phys. Med. Biol. , vol.26 , pp. 113-124
    • Jahns, M.J.1
  • 5
    • 0033955412 scopus 로고    scopus 로고
    • Characterization of scatter and penetration using Monte Carlo simulation in 1311 imaging
    • Y. K. Dewaraja, M. Ljungberg, and K. F. Koral, "Characterization of scatter and penetration using Monte Carlo simulation in 1311 imaging," J. Nucl. Med., vol. 41, pp. 123-130, 2000.
    • (2000) J. Nucl. Med. , vol.41 , pp. 123-130
    • Dewaraja, Y.K.1    Ljungberg, M.2    Koral, K.F.3
  • 6
    • 29144523756 scopus 로고    scopus 로고
    • Fast modeling of collimator-detector responses in Monte Carlo simulation of SPECT imaging using angular response functions
    • X. Song, E. C. Frey, W. P. Segars, Y. Du, and B. M. W. Tsui, "Fast modeling of collimator-detector responses in Monte Carlo simulation of SPECT imaging using angular response functions." Phys. Med. Biol. 2004.
    • (2004) Phys. Med. Biol.
    • Song, X.1    Frey, E.C.2    Segars, W.P.3    Du, Y.4    Tsui, B.M.W.5
  • 7
    • 11844265823 scopus 로고    scopus 로고
    • Fast Monte Carlo simulation of the crosstalk in simultaneous dual isotope SPECT
    • _, "Fast Monte Carlo simulation of the crosstalk in simultaneous dual isotope SPECT," J. Nucl. Med., vol. 44, pp. 64p-65p, 2003.
    • (2003) J. Nucl. Med. , vol.44
  • 8
    • 0033343646 scopus 로고    scopus 로고
    • A realistic spline-based dynamic heart phantom
    • W. P. Segars, D. S. Lalush, and B. M. W. Tsui, "A realistic spline-based dynamic heart phantom," IEEE Trans. Nucl. Sci., vol. 46, pp. 503-506, 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , pp. 503-506
    • Segars, W.P.1    Lalush, D.S.2    Tsui, B.M.W.3
  • 9
    • 0035246235 scopus 로고    scopus 로고
    • Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms
    • _, "Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms," IEEE Trans. Nucl. Sci., vol. 48, pp. 89-97, 2001.
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 89-97
  • 11
    • 0142174311 scopus 로고    scopus 로고
    • An improved phantom population for evaluation of myocardial perfusion SPECT imaging
    • X. He, E. Frey, W. Segars, K. Gilland, and B. Tsui, "An improved phantom population for evaluation of myocardial perfusion SPECT imaging." J. Nucl. Med., vol. 43, pp. 9p-10p, 2002.
    • (2002) J. Nucl. Med. , vol.43
    • He, X.1    Frey, E.2    Segars, W.3    Gilland, K.4    Tsui, B.5
  • 13
    • 84861299595 scopus 로고    scopus 로고
    • University of Washington,[Online]
    • SimSET Version 2.6. SIMSET Overview. University of Washington, 2004. [Online]http://depts.washington.edu/~simset/html/simset_home.html
    • (2004) SimSET Version 2.6. SIMSET Overview
  • 14
    • 0003063484 scopus 로고
    • A public-domain simulation system for emission tomography-photon tracking through heterogeneous attenuation using importance sampling
    • R. L. Harrison, D. R. Haynor, S. B. Gillispie, S. D. Vannoy, M. S. Kaplan, and T. K. Lewellen, "A public-domain simulation system for emission tomography-photon tracking through heterogeneous attenuation using importance sampling," J. Nucl. Med., vol. 34, pp. P60-P60, 1993.
    • (1993) J. Nucl. Med. , vol.34
    • Harrison, R.L.1    Haynor, D.R.2    Gillispie, S.B.3    Vannoy, S.D.4    Kaplan, M.S.5    Lewellen, T.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.