메뉴 건너뛰기




Volumn 13, Issue 4, 2009, Pages 318-322

Quality control in pulsed dose rate brachytherapy;Contrôle de qualité en curiethérapie de débit de dose pulsé

Author keywords

Brachytherapy; Pulsed dose rate; Quality control

Indexed keywords

ARTICLE; BRACHYTHERAPY; CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; HEALTH PROGRAM; HUMAN; MAJOR CLINICAL STUDY; MULTICENTER STUDY; PRIORITY JOURNAL; QUALITY CONTROL; RADIATION DOSE; TREATMENT PLANNING; UTERINE CERVIX CARCINOMA;

EID: 67649411550     PISSN: 12783218     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.canrad.2009.02.005     Document Type: Article
Times cited : (2)

References (16)
  • 1
    • 0038077546 scopus 로고    scopus 로고
    • Optimisation en curiethérapie
    • Briot E. Optimisation en curiethérapie. Cancer Radiother 7 (2003) 147-152
    • (2003) Cancer Radiother , vol.7 , pp. 147-152
    • Briot, E.1
  • 2
    • 67649405658 scopus 로고    scopus 로고
    • CAPCA (Canadian Association of Provincial Cancer Agencies) quality control standards: brachytherapy remote afterloaders. February 2005.
    • CAPCA (Canadian Association of Provincial Cancer Agencies) quality control standards: brachytherapy remote afterloaders. February 2005.
  • 4
    • 67649401313 scopus 로고    scopus 로고
    • ESTRO. A practical guide to quality control of brachytherapy equipment. Booklet No.8.
    • ESTRO. A practical guide to quality control of brachytherapy equipment. Booklet No.8.
  • 7
    • 33750453064 scopus 로고    scopus 로고
    • Nouveautés en curiethérapie gynécologique : nouvelles technologies, curiethérapie pulsée, imagerie, définitions de nouveaux volumes d'intérêt et leur impact sur la dosimétrie : applications dans le cadre d'un Stic
    • Haie-Meder C., and Peiffert D. Nouveautés en curiethérapie gynécologique : nouvelles technologies, curiethérapie pulsée, imagerie, définitions de nouveaux volumes d'intérêt et leur impact sur la dosimétrie : applications dans le cadre d'un Stic. Cancer Radiother 10 (2006) 402-409
    • (2006) Cancer Radiother , vol.10 , pp. 402-409
    • Haie-Meder, C.1    Peiffert, D.2
  • 8
    • 20044389263 scopus 로고    scopus 로고
    • Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV
    • Haie-Meder C., Potter R., Van Limbergen E., Briot E., De Brabandere M., Dimopoulos J., et al. Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV. Radiother Oncol 74 (2005) 235-245
    • (2005) Radiother Oncol , vol.74 , pp. 235-245
    • Haie-Meder, C.1    Potter, R.2    Van Limbergen, E.3    Briot, E.4    De Brabandere, M.5    Dimopoulos, J.6
  • 9
    • 67649391880 scopus 로고
    • ICRU. International Commission on Radiological Units and Measurements Dose and specification for reporting intracavitary therapy in gynecology, Bethesda, MD: ICRU;
    • ICRU. International Commission on Radiological Units and Measurements Dose and volume specification for reporting intracavitary therapy in gynecology, ICRU Report 38. Bethesda, MD: ICRU; 1985.
    • (1985) ICRU Report , vol.38
  • 10
    • 67649406930 scopus 로고    scopus 로고
    • Contrôle qualité des équipements de curiethérapie en France : pratique courante et minimum requis en 2002
    • Métayer Y., Peiffert D., Noel A., Aletti P., Buchheit I., and Laurens C. Contrôle qualité des équipements de curiethérapie en France : pratique courante et minimum requis en 2002. Cancer Radiother 6 suppl. 1 (2002) 195s
    • (2002) Cancer Radiother , vol.6 , Issue.SUPPL. 1
    • Métayer, Y.1    Peiffert, D.2    Noel, A.3    Aletti, P.4    Buchheit, I.5    Laurens, C.6
  • 11
    • 0030801752 scopus 로고    scopus 로고
    • Code of practice for brachytherapy physics: report of the AAPM Radiation Therapy Committee Task Group No. 56. American Association of Physicists in Medicine
    • Nath R., Anderson L.L., Meli J.A., Olch A.J., Stitt J.A., and Williamson J.F. Code of practice for brachytherapy physics: report of the AAPM Radiation Therapy Committee Task Group No. 56. American Association of Physicists in Medicine. Med Phys 24 (1997) 1557-1598
    • (1997) Med Phys , vol.24 , pp. 1557-1598
    • Nath, R.1    Anderson, L.L.2    Meli, J.A.3    Olch, A.J.4    Stitt, J.A.5    Williamson, J.F.6
  • 13
    • 34249087721 scopus 로고    scopus 로고
    • La curiethérapie en France en 2002 : résultats de l'enquête PCBE de l'ESTRO
    • Peiffert D., Mazeron J.J., Guedea F., and Nisin R. La curiethérapie en France en 2002 : résultats de l'enquête PCBE de l'ESTRO. Cancer Radiother 11 (2007) 146-149
    • (2007) Cancer Radiother , vol.11 , pp. 146-149
    • Peiffert, D.1    Mazeron, J.J.2    Guedea, F.3    Nisin, R.4
  • 14
    • 0038416070 scopus 로고    scopus 로고
    • La curiethérapie de débit pulsé : optimisation et place de l'imagerie
    • Poupon L., Castelain B., and Lartigau E. La curiethérapie de débit pulsé : optimisation et place de l'imagerie. Cancer Radiother 7 (2003) 136-146
    • (2003) Cancer Radiother , vol.7 , pp. 136-146
    • Poupon, L.1    Castelain, B.2    Lartigau, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.