Recommendations and quality control in brachytherapy;Recommandations pour le contrôle de qualité en curiethérapie

Author keywords

Brachytherapy; Quality assurance; Radioprotection

Indexed keywords

BIOSAFETY; BRACHYTHERAPY; CONFERENCE PAPER; DEVICE; ENERGY; MEDICAL INFORMATION; PHYSICAL PARAMETERS; PRIORITY JOURNAL; QUALITY CONTROL; RADIATION DOSE; RADIATION EXPOSURE; RADIATION PROTECTION; RADIOACTIVITY; REPRODUCIBILITY; TREATMENT PLANNING;

EID: 0036869019     PISSN: 12783218     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (9)
  • 1
    • 0032972488 scopus 로고    scopus 로고
    • Comparison of calibration procedures for 192 Ir HDR brachytherapy sources
    • Baltas D, Geramani K, Ioannidis GT. Comparison of calibration procedures for 192 Ir HDR brachytherapy sources. Int J Radiat Oncology Biol Phys 1999;43:653-61.
    • (1999) Int J Radiat Oncology Biol Phys , vol.43 , pp. 653-661
    • Baltas, D.1    Geramani, K.2    Ioannidis, G.T.3
  • 2
    • 0034255957 scopus 로고    scopus 로고
    • Impact on treatment outcome and late effects of customized treatment planning in cervix carcinomas: Baseline results to compare new strategies
    • Barillot I, Horiot J, Maingon P. Impact on treatment outcome and late effects of customized treatment planning in cervix carcinomas: Baseline results to compare new strategies. Int J Radiat Oncology Biol Phys 2000;48:189-200.
    • (2000) Int J Radiat Oncology Biol Phys , vol.48 , pp. 189-200
    • Barillot, I.1    Horiot, J.2    Maingon, P.3
  • 3
    • 0036159393 scopus 로고    scopus 로고
    • Quality control of brachytherapy equipment in the Netherlands and Belgium: Current practice and minimum requirements
    • Elfrink R, Kolkman-Deurloo IK, van Kleffens H, Rijnders A, Schaeken B, Aalbers T, et al. Quality control of brachytherapy equipment in the Netherlands and Belgium: Current practice and minimum requirements. Radiother Oncol 2002;62:95-102.
    • (2002) Radiother Oncol , vol.62 , pp. 95-102
    • Elfrink, R.1    Kolkman-Deurloo, I.K.2    Van Kleffens, H.3    Rijnders, A.4    Schaeken, B.5    Aalbers, T.6
  • 4
    • 0028321688 scopus 로고
    • Quality assurance of treatment plans for optimized high-dose-rate brachytherapy-planar implants
    • Ezzell GA. Quality assurance of treatment plans for optimized high-dose-rate brachytherapy-planar implants. Med Phys 1994;21:659-61.
    • (1994) Med Phys , vol.21 , pp. 659-661
    • Ezzell, G.A.1
  • 6
    • 0029804603 scopus 로고    scopus 로고
    • A method for verifying treatment times for simple endobronchial brachytherapy procedures
    • Miller AV, Davis MG, Horton JL. A method for verifying treatment times for simple endobronchial brachytherapy procedures. Med Phys 1996;23:1903-8.
    • (1996) Med Phys , vol.23 , pp. 1903-1908
    • Miller, A.V.1    Davis, M.G.2    Horton, J.L.3
  • 7
    • 0035915793 scopus 로고    scopus 로고
    • Survey of the use of the ICRU 38 in recording and reporting cervical cancer brachytherapy
    • Pötter R, Van Limbergen E, Gerstner N, Wambersie A. Survey of the use of the ICRU 38 in recording and reporting cervical cancer brachytherapy. Radiother Oncol 2001;58:11-8.
    • (2001) Radiother Oncol , vol.58 , pp. 11-18
    • Pötter, R.1    Van Limbergen, E.2    Gerstner, N.3    Wambersie, A.4
  • 9
    • 0029092628 scopus 로고
    • A method to check treatment time calculation in Ir-192 high-dose-rate volume implants
    • Venselaar J, Bierhuizen H, Klop R. A method to check treatment time calculation in Ir-192 high-dose-rate volume implants. Med Phys 1995;22:1499-500.
    • (1995) Med Phys , vol.22 , pp. 1499-1500
    • Venselaar, J.1    Bierhuizen, H.2    Klop, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.