메뉴 건너뛰기




Volumn 1, Issue 4, 2006, Pages 373-378

Cell-based assays for high-throughput screening

Author keywords

cell based screening; imaging; screening technology; stem cell; three dimensional cell culture

Indexed keywords


EID: 67649250297     PISSN: 17460441     EISSN: 1746045X     Source Type: Journal    
DOI: 10.1517/17460441.1.4.373     Document Type: Conference Paper
Times cited : (7)

References (8)
  • 1
    • 28544447780 scopus 로고    scopus 로고
    • The open microscopy environment data model and XML file: Open tools for informatics and quantitative analysis in biological imaging
    • GOLDBERG IG, ALLAN C, BUREL JM et al.: The open microscopy environment data model and XML file: open tools for informatics and quantitative analysis in biological imaging. Genome Biol. (2005) 6(5):R47.
    • (2005) Genome Biol. , vol.6 , Issue.5
    • Goldberg, I.G.1    Allan, C.2    Burel, J.M.3
  • 2
    • 12344332390 scopus 로고    scopus 로고
    • A novel high aspect ratio microfluidic design to provide a stable and uniform microenvironment for cell growth in a high throughput mammalian cell culture array
    • DOI 10.1039/b410743h
    • HUNG PJ, LEE PJ, SABOUNCHI P et al.: A novel high aspect ratio microfluidic design to provide a stable and uniform mivroenvironment for cell growth in a high-throughput mammalian cell culture array. Lab. Chip. (2005) 5:44-48. (Pubitemid 40139339)
    • (2005) Lab on a Chip - Miniaturisation for Chemistry and Biology , vol.5 , Issue.1 , pp. 44-48
    • Hung, P.J.1    Lee, P.J.2    Sabounchi, P.3    Aghdam, N.4    Lin, R.5    Lee, L.P.6
  • 3
    • 32044463563 scopus 로고    scopus 로고
    • Molecular and functional analysis using live cell microarrays
    • DOI 10.1016/j.cbpa.2006.01.001, PII S1367593106000020, Proteins and Genomics
    • CHEN DS, DAVIS MM: Molecular and functional analysis using live cell microarrays. Curr. Opin. Chem. Biol. (2006) 10:28-34. (Pubitemid 43202284)
    • (2006) Current Opinion in Chemical Biology , vol.10 , Issue.1 , pp. 28-34
    • Chen, D.S.1    Davis, M.M.2
  • 4
    • 22544477581 scopus 로고    scopus 로고
    • Aptamers as tool for target validation
    • BLANK, BLIND M: Aptamers as tool for target validation. Curr. Opin. Chem. Biol. (2005) 9:336-342.
    • (2005) Curr. Opin. Chem. Biol. , vol.9 , pp. 336-342
    • Blank Blind, M.1
  • 5
    • 24144436923 scopus 로고    scopus 로고
    • Evaluation of the InteraX™ system technology in a high-throughput screening environment
    • DOI 10.1177/1087057104272568
    • BÜTTNER FH, KUMPF R, MENZEL S, REULLE D, VALLER MJ: Evaluation of the InteraX system technology in a high-throughput screening environment. J. Biomol. Screen. (2005) 10(5):485-494. (Pubitemid 41233227)
    • (2005) Journal of Biomolecular Screening , vol.10 , Issue.5 , pp. 485-494
    • Buttner, F.H.1    Kumpf, R.2    Menzel, S.3    Reulle, D.4    Valler, M.J.5
  • 8
    • 0035991228 scopus 로고    scopus 로고
    • 1 cells maintained in a new perfusion cell culture system exhibit an improved oxidative metabolism
    • DOI 10.1159/000063792
    • FELDER E, JENNINGS P, SEPPI T, PFALLER W: LLC-PK1 cells maintained in a new perfusion cell culture system exhibit an improved oxidative metabolism. Cell. Physiol. Biochem. (2002) 12:153-162 (Pubitemid 34665139)
    • (2002) Cellular Physiology and Biochemistry , vol.12 , Issue.2-3 , pp. 153-162
    • Felder, E.1    Jennings, P.2    Seppi, T.3    Pfaller, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.