메뉴 건너뛰기




Volumn , Issue , 2008, Pages 5255-5259

Implementing analytical geometric and penetration response correction for keel-edge pinhole SPECT image reconstruction

Author keywords

GPRC; Image reconstruction; Keel edge pinhole collimator; Pinhole SPECT

Indexed keywords

APPROXIMATE NUMERICAL METHOD; COLLIMATOR RESPONSE; GEOMETRIC RESPONSE FUNCTIONS; GPRC; HIGH RESOLUTION; KEEL-EDGE PINHOLE COLLIMATOR; LOOK UP TABLE; MICRO SPECT; OSEM RECONSTRUCTION; PINHOLE COLLIMATORS; PINHOLE SPECT; QUANTITATIVE IMAGING; RECONSTRUCTED IMAGE; RESOLUTION RECOVERY; RESPONSE FUNCTIONS; SMALL-ANIMAL;

EID: 67649241024     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774419     Document Type: Conference Paper
Times cited : (3)

References (11)
  • 1
    • 0019136137 scopus 로고
    • The geometric transfer function component for scintillation camera collimators with straight parallel holes
    • C. E. Metz, F. B. Atkins, and R. N. Beck, "The geometric transfer function component for scintillation camera collimators with straight parallel holes", Phys.Med.Biol., Vol.25, No.6, pp. 1059-1070, 1980. (Pubitemid 11195964)
    • (1980) Physics in Medicine and Biology , vol.25 , Issue.6 , pp. 1059-1070
    • Metz, C.E.1    Atkins, F.B.2    Beck, R.N.3
  • 2
    • 0025070160 scopus 로고
    • The geometric transfer function for cone and fan beam collimators
    • B. M. W. Tsui and G.T. Gullberg, "The geometric transfer function for cone and fan beam collimators," Phys.Med.Biol., Vol.35, No.1, pp. 81-93,1990. (Pubitemid 20029079)
    • (1990) Physics in Medicine and Biology , vol.35 , Issue.1 , pp. 81-93
    • Tsui, B.M.W.1    Gullberg, G.T.2
  • 3
    • 0026139673 scopus 로고
    • Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correction
    • DOI 10.1109/23.289376
    • G.L. Zeng, and G. T. Gullberg, "Three-dimensional iterative reconstr0uction algorithms with attenuation and geometric point response correction," Trans. Nucl. Sci.,Vol.38, No.2, pp.693-702, June, 1991. (Pubitemid 21676686)
    • (1991) IEEE Transactions on Nuclear Science , vol.38 , Issue.2 PART I , pp. 693-702
    • Zeng, G.L.1    Gullberg, G.T.2    Tsui, B.M.W.3    Terry, J.A.4
  • 4
    • 0033778110 scopus 로고    scopus 로고
    • A three-dimensional ray-driven attenuation, scatter and geometric response correction technique for SPECT in inhomogeneous media
    • DOI 10.1088/0031-9155/45/11/325, PII S0031915500128386
    • I. Laurette, G.L. Zeng, A. Welch, P. E. Christian and G. T. Gullberg, "A three-dimensional ray-driven attenuation, scatter and geometric response correction technique for SPECT in inhomogeneous media," Phys. Med. Biol., Vol.45, pp. 3459-3480,2000. (Pubitemid 30836600)
    • (2000) Physics in Medicine and Biology , vol.45 , Issue.11 , pp. 3459-3480
    • Laurette, I.1    Zeng, G.L.2    Welch, A.3    Christian, P.E.4    Gullberg, G.T.5
  • 5
    • 0031961359 scopus 로고    scopus 로고
    • Improved estimation of the detector response function for converging beam collimators
    • DOI 10.1088/0031-9155/43/4/021, PII S0031915598897583
    • E.C.Frey, B.M.W.Tsui, G.T.Gullberg, "Improved estimation of the detector function for converging beam collimator," Phys. Med. BioI., Vol.43, pp.941-950, 1998. (Pubitemid 28168422)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.4 , pp. 941-950
    • Frey, E.C.1    Tsui, B.M.W.2    Gullberg, G.T.3
  • 6
    • 34247249006 scopus 로고    scopus 로고
    • Development and application of high-sensitivity and high-resolution fully 3D SPECT imaging techniques using two different collimator designs
    • Yuchuan Wang, "Development and application of high-sensitivity and high-resolution fully 3D SPECT imaging techniques using two different collimator designs," Ph.D. dissertation, The University of North Carolina at Chapel Hill, 2004.
    • (2004) Ph.D. Dissertation, The University of North Carolina at Chapel Hill
    • Wang, Y.1
  • 7
    • 23844533348 scopus 로고    scopus 로고
    • Determination of the analytical point spread function of a pinhole aperture SPECT system
    • M2-229, 2004 IEEE Nuclear Science Symposium Conference Record
    • V. Bekaert, D. Brasse, B. Gizard, and J.L. Guyonnet, "Determination of the analytical point spread function of a pinhole aperture SPECT system," in ConI Rec. IEEE Nuclear Science Symp., 2004, pp. 2565-2569 (Pubitemid 41148095)
    • (2004) IEEE Nuclear Science Symposium Conference Record , vol.4 , pp. 2565-2569
    • Bekaert, V.1    Brasse, D.2    Gizard, B.3    Guyonnet, J.-L.4
  • 8
    • 0031961517 scopus 로고    scopus 로고
    • An analytic model of pinhole aperture penetration for 3D pinhole SPECT image reconstruction
    • DOI 10.1088/0031-9155/43/4/006, PII S0031915598897649
    • M. F. Smith and R.J. Jaszczak, "An analytic model of pinhole aperture penetration for 3D pinhole SPECr image reconstruction", Phys.Med.Biol., Vo1.43, pp. 761-775, 1998. (Pubitemid 28168407)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.4 , pp. 761-775
    • Smith, M.F.1    Jaszczak, R.J.2
  • 9
    • 0035413309 scopus 로고    scopus 로고
    • Analytic determination of pinhole collimator sensitivity with penetration
    • S. D. Metzler,J. E. Bowsher, M. F. Smith and R. J. Jaszczak, "Analytic determination of pinhole collimator sensitivity with penetration," IEEE Trans .Med Img., Vol.20, pp.730 -741, 2001.
    • (2001) IEEE Trans .Med. Img. , vol.20 , pp. 730-741
    • Metzler, S.D.1    Bowsher, J.E.2    Smith, M.F.3    Jaszczak, R.J.4
  • 10
    • 33846925893 scopus 로고    scopus 로고
    • Optimized collimator designs for small animal SPECT imaging with a compact gamma camera
    • 1616792, Proceedings of the 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
    • Yujin Qi, "Optimized Collimator Designs for Small Animal SPECr Imaging With a Compact Gamma Camera," in IEEE EMBS Conf., 2005, pp.1780-1782. (Pubitemid 46229243)
    • (2005) Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings , vol.7 , pp. 1780-1782
    • Qi, Y.1
  • 11
    • 48349145412 scopus 로고    scopus 로고
    • Performance Comparison of Subtractive resistive readout with conventional resistive readout for high-resolution compact gamma camera
    • Y.J.Qi, M.J.Zhang, C.L.Zhao and R.F.Wojcik, "Performance Comparison of Subtractive resistive readout with conventional resistive readout for high-resolution compact gamma camera," in Conf. Rec. IEEE Nuclear Science Symp." 2007, pp. 3725-3728.
    • (2007) Conf. Rec. IEEE Nuclear Science Symp , pp. 3725-3728
    • Qi, Y.J.1    Zhang, M.J.2    Zhao, C.L.3    Wojcik, R.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.