메뉴 건너뛰기




Volumn 5, Issue , 2007, Pages 3725-3728

Performance comparison of subtractive resistive readout with conventional resistive readout for a high-resolution Compact Gamma Camera

Author keywords

[No Author keywords available]

Indexed keywords

CESIUM; MEDICAL IMAGING; POWDERS; X RAY CAMERAS;

EID: 48349145412     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4436931     Document Type: Conference Paper
Times cited : (19)

References (12)
  • 1
    • 0032100078 scopus 로고    scopus 로고
    • High Spatial resolution Gamma Imaging Detector Based on 5 Diameter R3292 Hamamatsu PSPMT
    • June
    • R.Wojcik, S. Majewski, D. Steinbach and A.G. Weisenberger, "High Spatial resolution Gamma Imaging Detector Based on 5" Diameter R3292 Hamamatsu PSPMT," IEEE Trans. Nucl. Sci., vol. 45, no.3, pp.487-491, June, 1998.
    • (1998) IEEE Trans. Nucl. Sci , vol.45 , Issue.3 , pp. 487-491
    • Wojcik, R.1    Majewski, S.2    Steinbach, D.3    Weisenberger, A.G.4
  • 2
    • 0034204676 scopus 로고    scopus 로고
    • Compact high resolution detector for small animal SPECT
    • June
    • N. Schramm, A. Wirrwar, F. Sonnenberg, and H. Hailing. "Compact high resolution detector for small animal SPECT," IEEE Trans. Nucl. Sci., vol. 47, pp. 1163-1167, June, 2000.
    • (2000) IEEE Trans. Nucl. Sci , vol.47 , pp. 1163-1167
    • Schramm, N.1    Wirrwar, A.2    Sonnenberg, F.3    Hailing, H.4
  • 5
    • 0142242006 scopus 로고    scopus 로고
    • R. Pani, R. Pellegrini, M.N. Cinti, C. Trotta. G. Trotta, R. Scafe, M. Betti, F. Cusanno, L. Montani. G. Iurlaro, F. Garbaldi, Del A. Guerra. A novel comapct gamma camera based on flat panel PMT, Nucl. Instr. Meth. Phys. Res A, 513, no.1, pp36-41, 2003.
    • R. Pani, R. Pellegrini, M.N. Cinti, C. Trotta. G. Trotta, R. Scafe, M. Betti, F. Cusanno, L. Montani. G. Iurlaro, F. Garbaldi, Del A. Guerra. "A novel comapct gamma camera based on flat panel PMT," Nucl. Instr. Meth. Phys. Res A, vol. 513, no.1, pp36-41, 2003.
  • 6
    • 20344406039 scopus 로고    scopus 로고
    • Development and characterization of a high-resolution microSPECT system for small animal imaging
    • M.A. Kupinski and H.H. Barrett, Eds. New York: Springer. Chapter 21, 2005, pp
    • Y. Qi, B.M.W. Tsui, Y. Wang, B. Yoder, A. Weisenberger, R. Wojcik and S. Majewski, "Development and characterization of a high-resolution microSPECT system for small animal imaging", Small-Animal SPECT Imaging, M.A. Kupinski and H.H. Barrett, Eds. New York: Springer. Chapter 21, 2005, pp.259-266.
    • Small-Animal SPECT Imaging , pp. 259-266
    • Qi, Y.1    Tsui, B.M.W.2    Wang, Y.3    Yoder, B.4    Weisenberger, A.5    Wojcik, R.6    Majewski, S.7
  • 7
    • 36849139664 scopus 로고
    • Scintillation camera
    • H. Anger, "Scintillation camera," Rev Sci. Inst., vol.29, no. 1, pp.27-33, 1958.
    • (1958) Rev Sci. Inst , vol.29 , Issue.1 , pp. 27-33
    • Anger, H.1
  • 8
    • 0030164341 scopus 로고    scopus 로고
    • Simple charge division readout for imaging scintillator arrays using a multi-channel PMT
    • Stefan Siegel, Robert W. Silverman, Yiping Shao, Simon R.Cherry. "Simple charge division readout for imaging scintillator arrays using a multi-channel PMT," IEEE Trans. Nucl. Sci., vol. 43, no. 3, pp. 16341641, 1996.
    • (1996) IEEE Trans. Nucl. Sci , vol.43 , Issue.3 , pp. 16341641
    • Siegel, S.1    Silverman, R.W.2    Shao, Y.3    Cherry, S.R.4
  • 9
    • 0034062349 scopus 로고    scopus 로고
    • Mark B. Williams, Allen R.Goode, victor Galbis-Reig, Stan Majewski, Andrew G. Weisenberger, and Randolph Wojcik, Performance of a PSPMT based detector for scintimammography, Phys.Med. Biol, 45, pp.781-800, 2000.
    • Mark B. Williams, Allen R.Goode, victor Galbis-Reig, Stan Majewski, Andrew G. Weisenberger, and Randolph Wojcik, "Performance of a PSPMT based detector for scintimammography," Phys.Med. Biol, 45, pp.781-800, 2000.
  • 10
    • 11844267195 scopus 로고    scopus 로고
    • Prototype parallel readout system for position sensitive PNT based gamma ray imaging systems
    • Frezghi Habte, Peter D. Olcott, Craig S. Levin, Angela M. Foudray, and Jonathon A. Talcott, " Prototype parallel readout system for position sensitive PNT based gamma ray imaging systems," in Proc. IEEE Nucl. Sci. Symp.Conf. Rec., vol. 4, pp. 1891-1894, 2003.
    • (2003) Proc. IEEE Nucl. Sci. Symp.Conf. Rec , vol.4 , pp. 1891-1894
    • Habte, F.1    Olcott, P.D.2    Levin, C.S.3    Foudray, A.M.4    Talcott, J.A.5
  • 11
    • 0035555254 scopus 로고    scopus 로고
    • R. Wojcik, S. Majewski, B. Kross, V. Popov, and A.G. Weisenberger, Optimized readout of small gamma cameras for high resolution single gamma and positron emission imaging,2001 IEEE NSS-MIC Conference Record, San Diego, Nov.4-10, 2001.
    • R. Wojcik, S. Majewski, B. Kross, V. Popov, and A.G. Weisenberger, "Optimized readout of small gamma cameras for high resolution single gamma and positron emission imaging,"2001 IEEE NSS-MIC Conference Record, San Diego, Nov.4-10, 2001.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.