메뉴 건너뛰기




Volumn 18, Issue 3, 2009, Pages 205-218

Ventilation control of indoor transmission of airborne diseases in an Urban community

Author keywords

Airborne disease; Engineering control; Influenza; SEIR model; Ventilation; Wellsg Riley equation

Indexed keywords

AIR CONDITIONING; AIRBORNE INFECTION; ARTICLE; COMMUNITY; DISEASE CONTROL; DISEASE TRANSMISSION; FILTER; HEALTH CARE FACILITY; HEATING; MATHEMATICAL MODEL; PRIORITY JOURNAL; ROOM TEMPERATURE; ROOM VENTILATION; ULTRAVIOLET IRRADIATION; URBAN POPULATION;

EID: 67649233606     PISSN: 1420326X     EISSN: 14230070     Source Type: Journal    
DOI: 10.1177/1420326X09104141     Document Type: Article
Times cited : (41)

References (42)
  • 1
    • 4444348103 scopus 로고    scopus 로고
    • Airborne Transmission of Communicable Infection - The Elusive Pathway
    • DOI 10.1056/NEJMp048051
    • Roy CJ, Milton DK: Airborne transmission of communicable infection-the elusive pathway: N Engl J Med 2004 ; 350 (17). 1710-1712. (Pubitemid 38501139)
    • (2004) New England Journal of Medicine , vol.350 , Issue.17 , pp. 1710-1712
    • Roy, C.J.1    Milton, D.K.2
  • 2
    • 0031183556 scopus 로고    scopus 로고
    • Using a Mathematical Model to Evaluate the Efficacy of TB Control Measures
    • Gammaitoni L., Nucci MC: Using a mathematical model to evaluate the efficacy of TB control measures: Emerg Infect Dis 1997 ; 3 (3). 335-342. (Pubitemid 127431694)
    • (1997) Emerging Infectious Diseases , vol.3 , Issue.3 , pp. 335-342
    • Gammaitoni, L.1    Nucci, M.C.2
  • 3
    • 1642619104 scopus 로고    scopus 로고
    • Development of a numerical model to simulate the biological inactivation of airborne microorganisms in the presence of ultraviolet light
    • DOI 10.1016/j.jaerosci.2003.10.011, PII S0021850203004488
    • Noakes CJ, Fletcher LA, Beggs CB, Sleigh PA, Kerr KG: Development of a numerical model to simulate the biological inactivation of airborne microorganisms in the presence of ultraviolet light: J Aerosol Sci 2004 ; 35 (4). 489-507. (Pubitemid 38410922)
    • (2004) Journal of Aerosol Science , vol.35 , Issue.4 , pp. 489-507
    • Noakes, C.J.1    Fletcher, L.A.2    Beggs, C.B.3    Sleigh, P.A.4    Kerr, K.G.5
  • 4
    • 33750569806 scopus 로고    scopus 로고
    • Review of aerosol transmission of influenza A virus
    • Tellier R.: Review of aerosol transmission of influenza A virus: Emerg Infect Dis 2006 ; 12 (11). 1657-1662. (Pubitemid 44674240)
    • (2006) Emerging Infectious Diseases , vol.12 , Issue.11 , pp. 1657-1662
    • Tellier, R.1
  • 7
    • 10944220947 scopus 로고    scopus 로고
    • Social and environmental risk factors in the emergence of infectious diseases
    • Weiss RA, McMichael AJ: Social and environmental risk factors in the emergence of infectious diseases: Nat Med 2004 ; 10 (12). S70 - S76.
    • (2004) Nat Med , vol.10 , Issue.12
    • Weiss, R.A.1    McMichael, A.J.2
  • 8
    • 38349106332 scopus 로고    scopus 로고
    • UV air cleaners and upper-room air ultraviolet germicidal irradiation for controlling airborne bacteria and fungal spores
    • Kujundzic E., Matalkah F., Howard CJ, Mark H., Miller SL: UV air cleaners and upper-room air ultraviolet germicidal irradiation for controlling airborne bacteria and fungal spores: J Occup Environ Hyg 2006 ; 3 (10). 536-546.
    • (2006) J Occup Environ Hyg , vol.3 , Issue.10 , pp. 536-546
    • Kujundzic, E.1    Matalkah, F.2    Howard, C.J.3    Mark, H.4    Miller, S.L.5
  • 9
    • 0033328018 scopus 로고    scopus 로고
    • Filtration of airborne microorganism: Modeling and prediction
    • Kowalski WJ, Bahnfleth WP, Whittam TS: Filtration of airborne microorganism: modeling and prediction ASHRAE Transactions 1999 ; 105 (2). 4-17.
    • (1999) ASHRAE Transactions , vol.105 , Issue.2 , pp. 4-17
    • Kowalski, W.J.1    Bahnfleth, W.P.2    Whittam, T.S.3
  • 11
    • 0034544637 scopus 로고    scopus 로고
    • Evaluation of a methodology for quantifying the effect of room air ultraviolet germicidal irradiation on airborne bacteria
    • DOI 10.1080/027868200416259
    • Miller SL, Macher JM: Evaluation of a methodology for quantifying the effect of room air ultraviolet germicidal irradiation on airborne bacteria: Aerosol Sci Technol 2000 ; 33 (3). 274-295. (Pubitemid 32003508)
    • (2000) Aerosol Science and Technology , vol.33 , Issue.3 , pp. 274-295
    • Miller, S.L.1    Macher, J.M.2
  • 12
    • 0037220814 scopus 로고    scopus 로고
    • Efficacy of ultraviolet germicidal irradiation of upper-room air in inactivating airborne bacterial spores and mycobacteria in full-scale studies
    • DOI 10.1016/S1352-2310(02)00825-7, PII S1352231002008257
    • Xu P., Peccia J., Fabian P., Martyny JW, Fennelly KP, Hernandez M., Miller SL: Efficacy of ultraviolet germicidal irradiation of upper-room air in inactivating airborne bacterial spores and mycobacteria in full-scale studies: Atmos Environ 2003 ; 37 (3). 405-419. (Pubitemid 36043945)
    • (2003) Atmospheric Environment , vol.37 , Issue.3 , pp. 405-419
    • Xu, P.1    Peccia, J.2    Fabian, P.3    Martyny, J.W.4    Fennelly, K.P.5    Hernandez, M.6    Miller, S.L.7
  • 13
    • 0035700808 scopus 로고    scopus 로고
    • Estimation of tuberculosis risk and incidence under upper room ultraviolet germicidal irradiation in a waiting room in a hypothetical scenario
    • DOI 10.1111/0272-4332.214142
    • Ko G., Burge HA, Nardell EA, Thompson KM: Estimation of tuberculosis risk and incidence under upper room ultraviolet germicidal irradiation in a waiting room in a hypothetical scenario: Risk Anal 2001 ; 21 (4). 657-673. (Pubitemid 34103005)
    • (2001) Risk Analysis , vol.21 , Issue.4 , pp. 657-673
    • Ko, G.1    Burge, H.A.2    Nardell, E.A.3    Thompson, K.M.4
  • 15
    • 33748353242 scopus 로고    scopus 로고
    • Modelling the transmission of airborne infections in enclosed spaces
    • DOI 10.1017/S0950268806005875, PII S0950268806005875
    • Noakes CJ, Beggs CB, Sleigh PA, Kerr KG: Modelling the transmission of airborne infections in enclosed spaces: Epidemiol Infect 2006 ; 134 (5). 1082-1091. (Pubitemid 44336386)
    • (2006) Epidemiology and Infection , vol.134 , Issue.5 , pp. 1082-1091
    • Noakes, C.J.1    Beggs, C.B.2    Sleigh, P.A.3    Kerr, K.G.4
  • 16
    • 39049103281 scopus 로고    scopus 로고
    • Modelling respiratory infection control measure effects
    • DOI 10.1017/S0950268807008631, PII S0950268807008631
    • Liao CM, Chen SC, Chang CF: Modelling respiratory infection control measure effects: Epidemiol Infect 2008 ; 136 (3). 299-308. (Pubitemid 351233845)
    • (2008) Epidemiology and Infection , vol.136 , Issue.3 , pp. 299-308
    • Liao, C.-M.1    Chen, S.C.2    Chang, C.F.3
  • 18
    • 36348971666 scopus 로고    scopus 로고
    • Transmission of influenza A in human beings
    • Tang JW, Li Y.: Transmission of influenza A in human beings: Lancet Infect Dis 2007 ; 7 (12). 761-763.
    • (2007) Lancet Infect Dis , vol.7 , Issue.12 , pp. 761-763
    • Tang, J.W.1    Li, Y.2
  • 20
    • 0033539297 scopus 로고    scopus 로고
    • DOI 10.1016/S0140-6736(99)01241-6
    • Cox NJ, Subbarao K.: Influenza: Lancet 1999 ; 354 (9186). 1277-1282. (Pubitemid 29469365)
    • (1999) Influenza: Lancet , vol.354 , Issue.9186 , pp. 1277-1282
    • Cox, N.J.1    Subbarao, K.2
  • 21
    • 0028906704 scopus 로고
    • Respiratory protection and the risk of Mycobacterium tuberculosis infection
    • Nicas M.: Respiratory protection and the risk of Mycobacterium tuberculosis infection: Am J Ind Med 1995 ; 27 (3). 317-333.
    • (1995) Am J Ind Med , vol.27 , Issue.3 , pp. 317-333
    • Nicas, M.1
  • 22
    • 0036852838 scopus 로고    scopus 로고
    • A quantitative method for evaluating the germicidal effect of upper room UV fields
    • DOI 10.1016/S0021-8502(02)00117-9, PII S0021850202001179
    • Beggs CB, Sleigh PA: A quantitative method for evaluating the germicidal effect of upper room UV fields: J Aerosol Sci 2002 ; 33 (12). 1681-1699. (Pubitemid 35375930)
    • (2002) Journal of Aerosol Science , vol.33 , Issue.12 , pp. 1681-1699
    • Beggs, C.B.1    Sleigh, P.A.2
  • 23
    • 0000132475 scopus 로고
    • Inactivation of airborne viruses by ultraviolet irradiation
    • Jensen MM: Inactivation of airborne viruses by ultraviolet irradiation: Appl Microbiol 1964 ; 12: 418-420.
    • (1964) Appl Microbiol , vol.12 , pp. 418-420
    • Jensen, M.M.1
  • 24
    • 0018573316 scopus 로고
    • An outbreak of influenza aboard a commercial airliner
    • Moser MR, Bender TR, Margolis HS, Noble GR, Kendal AP, Ritter DG: An outbreak of influenza aboard a commercial airliner: Am J Epidemiol 1979 ; 110 (1). 1-6. (Pubitemid 10207328)
    • (1979) American Journal of Epidemiology , vol.110 , Issue.1 , pp. 1-6
    • Moser, M.R.1    Bender, T.R.2    Margolis, H.S.3
  • 25
    • 0029807274 scopus 로고    scopus 로고
    • Emerging infections: Pandemic influenza
    • Glezen WP: Emerging infections: pandemic influenza: Epidemiol Rev 1996 ; 18 (1). 64-76. (Pubitemid 26303555)
    • (1996) Epidemiologic Reviews , vol.18 , Issue.1 , pp. 64-76
    • Glezen, W.P.1
  • 27
    • 33749039988 scopus 로고    scopus 로고
    • Reducing the impact of the next influenza pandemic using household-based public health interventions
    • Wu JT, Riley S., Fraser C., Leung GM: Reducing the impact of the next influenza pandemic using household-based public health interventions: PLoS Med 2006 ; 3 (9). e361.
    • (2006) PLoS Med , vol.3 , Issue.9 , pp. 361
    • Wu, J.T.1    Riley, S.2    Fraser, C.3    Leung, G.M.4
  • 28
    • 0034745116 scopus 로고    scopus 로고
    • An empirical model for outdoor contaminant transmission into residential buildings and experimental verification
    • Chao CYH, Tung TC: An empirical model for outdoor contaminant transmission into residential buildings and experimental verification: Atmos Environ 2001 ; 35 (9). 1585-1596.
    • (2001) Atmos Environ , vol.35 , Issue.9 , pp. 1585-1596
    • Chao, C.Y.H.1    Tung, T.C.2
  • 29
    • 0035501568 scopus 로고    scopus 로고
    • Comparison between indoor and outdoor air contaminant levels in residential buildings from passive sampler study
    • DOI 10.1016/S0360-1323(00)00057-3, PII S0360132300000573
    • Chao CYH: Comparison between indoor and outdoor air contaminant levels in residential buildings from passive sampler study: Building Environ 2001 ; 36 (9). 999-1007. (Pubitemid 32926090)
    • (2001) Building and Environment , vol.36 , Issue.9 , pp. 999-1007
    • Chao, C.Y.H.1
  • 31
    • 0142088837 scopus 로고    scopus 로고
    • The outdoor air ventilation rate in high-rise residences employing room air conditioners
    • Lin ZP, Deng SM: The outdoor air ventilation rate in high-rise residences employing room air conditioners: Building Environ 2003 ; 38 (12). 1389-1399.
    • (2003) Building Environ , vol.38 , Issue.12 , pp. 1389-1399
    • Lin, Z.P.1    Deng, S.M.2
  • 32
    • 0141941245 scopus 로고    scopus 로고
    • Risk of indoor airborne infection transmission estimated from carbon dioxide concentration
    • DOI 10.1034/j.1600-0668.2003.00189.x
    • Rudnick SN, Milton DK: Risk of indoor airborne infection transmission estimated from carbon dioxide concentration: Indoor Air 2003 ; 13 (3). 237-245. (Pubitemid 37465470)
    • (2003) Indoor Air , vol.13 , Issue.3 , pp. 237-245
    • Rudnick, S.N.1    Milton, D.K.2
  • 33
    • 33750896281 scopus 로고    scopus 로고
    • Using data on social contacts to estimate age-specific transmission parameters for respiratory-spread infectious agents
    • DOI 10.1093/aje/kwj317
    • Wallinga J., Teunis P., Kretzschmar M.: Using data on social contacts to estimate age-specific transmission parameters for respiratory-spread infectious agents: Am J Epidemiol 2006 ; 164 (10). 936-944. (Pubitemid 44729833)
    • (2006) American Journal of Epidemiology , vol.164 , Issue.10 , pp. 936-944
    • Wallinga, J.1    Teunis, P.2    Kretzschmar, M.3
  • 34
    • 2142651557 scopus 로고    scopus 로고
    • Modeling infection transmission
    • DOI 10.1146/annurev.publhealth.25.102802.124353
    • Koopman J.: Modeling infection transmission: Annu Rev Public Health 2004 ; 25: 303-326. (Pubitemid 38543619)
    • (2004) Annual Review of Public Health , vol.25 , pp. 303-326
    • Koopman, J.1
  • 35
    • 0025931291 scopus 로고
    • Contributions to the mathematical theory of epidemics-III. Further studies of the problem of endemicity. 1933
    • Kermack WO, McKendrick AG: Contributions to the mathematical theory of epidemics-III. Further studies of the problem of endemicity. 1933: Bull Math Biol 1991 ; 53 (1-2). 89-118.
    • (1991) Bull Math Biol , vol.53 , Issue.1-2 , pp. 89-118
    • Kermack, W.O.1    McKendrick, A.G.2
  • 36
    • 0025985904 scopus 로고
    • Contributions to the mathematical theory of epidemics-II. the problem of endemicity.1932
    • Kermack WO, McKendrick AG: Contributions to the mathematical theory of epidemics-II. The problem of endemicity.1932: Bull Math Biol 1991 ; 53 (1-2). 57-87.
    • (1991) Bull Math Biol , vol.53 , Issue.1-2 , pp. 57-87
    • Kermack, W.O.1    McKendrick, A.G.2
  • 37
    • 0025985176 scopus 로고
    • Contributions to the mathematical theory of epidemics-I. 1927
    • Kermack WO, McKendrick AG: Contributions to the mathematical theory of epidemics-I. 1927: Bull Math Biol 1991 ; 53 (1-2). 33-55.
    • (1991) Bull Math Biol , vol.53 , Issue.1-2 , pp. 33-55
    • Kermack, W.O.1    McKendrick, A.G.2
  • 38
    • 0036847088 scopus 로고    scopus 로고
    • Daniel Bernoulli's epidemiological model revisited
    • DOI 10.1016/S0025-5564(02)00122-0, PII S0025556402001220
    • Dietz K., Heesterbeek JA: Daniel Bernoulli's epidemiological model revisited: Math Biosci 2002 ; 180: 1-21. (Pubitemid 35304344)
    • (2002) Mathematical Biosciences , vol.180 , pp. 1-21
    • Dietz, K.1    Heesterbeek, J.A.P.2
  • 40
    • 0018122939 scopus 로고
    • Airborne spread of measles in a suburban elementary school
    • Riley EC, Murphy G., Riley RL: Airborne spread of measles in a suburban elementary school: Am J Epidemiol 1978 ; 107 (5). 421-432. (Pubitemid 9003488)
    • (1978) American Journal of Epidemiology , vol.107 , Issue.5 , pp. 421-432
    • Riley, E.C.1    Murphy, G.2    Riley, R.L.3
  • 42
    • 33750738888 scopus 로고    scopus 로고
    • Predictive models of control strategies involved in containing indoor airborne infections
    • DOI 10.1111/j.1600-0668.2006.00443.x
    • Chen S-C., Chang C-F., Liao C-M.: Predictive models of control strategies involved in containing indoor airborne infections: Indoor Air 2006 ; 16: 469-481. (Pubitemid 44707160)
    • (2006) Indoor Air , vol.16 , Issue.6 , pp. 469-481
    • Chen, S.-C.1    Chang, C.-F.2    Liao, C.-M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.