메뉴 건너뛰기




Volumn , Issue , 2008, Pages 5053-5059

A practical, semi-experimental system matrix for 2-D PET image reconstruction: comparison with a geometrical model

Author keywords

[No Author keywords available]

Indexed keywords

BACK-PROJECTION; COMPUTATION TIME; CONTRAST TO NOISE RATIO; EXPERIMENTAL SYSTEM; FLUORODEOXYGLUCOSE; GEOMETRICAL MODELS; IMAGE ACCURACY; LINE INTEGRALS; MATRIX ELEMENTS; ON-THE-FLY; PET IMAGE RECONSTRUCTION; POINT SOURCES; PRACTICAL PROCEDURES; RECONSTRUCTED IMAGE; RECONSTRUCTION METHOD; STORAGE SPACES; SYSTEM MATRICES; SYSTEM RESPONSE;

EID: 67649188208     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774375     Document Type: Conference Paper
Times cited : (4)

References (17)
  • 1
    • 33746191812 scopus 로고    scopus 로고
    • Fully 3-D PET reconstruction with system matrix derived from point source measurements
    • DOI 10.1109/TMI.2006.876171, 1644806
    • V. Y. Panin, F. Kehren, C. Michel et aI., "Fully 3-D PET reconstruction with system matrix derived from point source measurements," IEEE Trans Med Imaging, vol. 25, no. 7, pp. 907-21, Jul, 2006. (Pubitemid 44088375)
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , Issue.7 , pp. 907-921
    • Panin, V.Y.1    Kehren, F.2    Michel, C.3    Casey, M.4
  • 2
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • DOI 10.1118/1.595715
    • R. Siddon, "Fast calculation of the exact radiological path for a threedimensional CT array," Med Phys, vol.12, no. 2, pp. 252-255, Mar-Apr, 1985. (Pubitemid 15089015)
    • (1985) Medical Physics , vol.12 , Issue.2 , pp. 252-255
    • Siddon, R.L.1
  • 3
    • 33947277900 scopus 로고    scopus 로고
    • Analytical calculation of volumes-of-intersection for iterative, fully 3-D PET reconstruction
    • DOI 10.1109/TMI.2006.880679
    • Scheins, F. Boschen, and H. Herzog, "Analytical calculation of volumes-of-intersection for iterative, fully 3-D PET reconstruction," IEEE Trans Med Imaging, vol.25, no. 10, pp. 1363-1369, Oct, 2006. (Pubitemid 46417084)
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , Issue.10 , pp. 1363-1369
    • Scheins, J.J.1    Boschen, F.2    Herzog, H.3
  • 4
    • 0031981253 scopus 로고    scopus 로고
    • High-resolution 3D bayesian image reconstruction using the microPET small-animal scanner
    • DOI 10.1088/0031-9155/43/4/027, PII S0031915598906273
    • J. Qi, R. M. Leahy, S. R. Cherry et aI., "High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner," Phys Med BioI, vol.43, no. 4, pp. 1001-1013, Apr, 1998. (Pubitemid 28168428)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.4 , pp. 1001-1013
    • Qi, J.1    Leahy, R.M.2    Cherry, S.R.3    Chatziioannou, A.4    Farquhar, T.H.5
  • 5
    • 0038029539 scopus 로고    scopus 로고
    • An improved analytical detector response function model multilayer small-diameter PET scanners
    • DOI 10.1088/0031-9155/48/8/302, PII S0031915503572384
    • D. Strul, R. B. Slates, M. Dahlbom et aI., "An improved analytical detector response function model for multilayer small-diameter PET scanners," Phys Med BioI, vol.48, no. 8, pp. 979-994, Apr 21,2003. (Pubitemid 36553317)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.8 , pp. 979-994
    • Strul, D.1    Slates, R.B.2    Dahlbom, M.3    Cherry, S.R.4    Marsden, P.K.5
  • 6
    • 8344282096 scopus 로고    scopus 로고
    • Use of a Monte-Carlo based probability matrix for 3D iterative reconstruction of MADPET-II data
    • M. Rafecas, B. Mosler, M. Dietz et aI., "Use of a Monte-Carlo based probability matrix for 3D iterative reconstruction of MADPET-II data," IEEE Trans Nucl Sci, vol.51, no. 5, pp. 2597 - 2605, 2004.
    • (2004) IEEE Trans Nucl Sci , vol.51 , Issue.5 , pp. 2597-2605
    • Rafecas, M.1    Mosler, B.2    Dietz, M.3
  • 7
    • 33645679019 scopus 로고    scopus 로고
    • PET reconstruction with system matrix derived from point source measurements
    • V. Y. Panin, F. Kehren, H. Rothfuss et aI., "PET Reconstruction With System Matrix Derived From Point Source Measurements," IEEE Trans Nucl Sci, vol.53, no. 1, pp. 152-159,2006.
    • IEEE Trans Nucl Sci , vol.53 , Issue.1 , pp. 152-159
    • Panin, V.Y.1    Kehren, F.2    Rothfuss, H.3
  • 8
    • 33644874714 scopus 로고    scopus 로고
    • Performance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the National Electrical Manufacturers Association NU 2-2001 standard
    • M. Brambilla, C. Secco, M. Dominietto et aI., "Performance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET scanner with the National Electrical Manufacturers Association NU 2-2001 standard," J Nucl Med, vol.46, no. 12, pp. 2083-2091, Dec, 2005. (Pubitemid 46657457)
    • (2005) Journal of Nuclear Medicine , vol.46 , Issue.12 , pp. 2083-2091
    • Brambilla, M.1    Secco, C.2    Dominietto, M.3    Matheoud, R.4    Sacchetti, G.5    Inglese, E.6
  • 9
    • 0020194763 scopus 로고
    • MAXIMUM LIKELIHOOD RECONSTRUCTION FOR EMISSION TOMOGRAPHY.
    • Shepp, and Y. Vardi, "Maximum likelihood reconstruction for emission tomography," IEEE Trans Med Imaging, vol.1, no. 2, pp. 113-122, October 1982. (Pubitemid 13557763)
    • (1982) IEEE Transactions on Medical Imaging , vol.MI-1 , Issue.2 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 10
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • H. Hudson, and R. Larkin, "Accelerated Image Reconstruction using Ordered Subsets of Projection Data," IEEE Trans Med Imaging, vol.13, pp. 601-609, 1994.
    • (1994) IEEE Trans Med Imaging , vol.13 , pp. 601-609
    • Hudson, H.1    Larkin, R.2
  • 12
    • 0002349614 scopus 로고    scopus 로고
    • Algorithm for computer control of a digital plotter
    • E. Bresenham, "Algorithm for computer control of a digital plotter," IBM SY"itemsJoumal, vol. 4, no. 1, pp. 25-30,1965.
    • IBM System Journal , vol.4 , Issue.1 , pp. 25-30
    • Bresenham, E.1
  • 14
    • 0033262047 scopus 로고    scopus 로고
    • Problemes inverses en tomographie d'emission - Nouvelles tendances
    • Garnero, 1. Fonroget, F. Coutand et aI., "Problemes inverses en tomographie d'emission - Nouvelles tendances," Ann Phys, vol.34, no. 3, pp. 153-193, 1999.
    • (1999) Ann Phys , vol.34 , Issue.3 , pp. 153-193
    • Garnero, L.1    Fonroget, J.2    Coutand, F.3
  • 15
    • 0035413317 scopus 로고    scopus 로고
    • Comparison of 3-D reconstruction with 3D-OSEM and with FORE+OSEM for PET
    • aug.
    • X. Liu, C. Comtat, C. Michel et aI., "Comparison of 3-D reconstruction with 3D-OSEM and with FORE+OSEM for PET," IEEE Trans Med Imaging, vol.20, no. 8, pp. 804-814, Aug, 2001.
    • (2001) IEEE Trans Med Imaging , vol.20 , Issue.8 , pp. 804-814
    • Liu, X.1    Comtat, C.2    Michel, C.3
  • 16
    • 0033316916 scopus 로고    scopus 로고
    • Image oscillation reduction and convergence acceleration for OS-EM reconstruction
    • DOI 10.1109/23.775586
    • S.-C. Huang, "Image oscillation reduction and convergence acceleration for OS-EM reconstruction [PET imaging]," Nuclear Science, IEEE Transactions on, vol.46, no. 3, pp. 603 - 607, 1999. (Pubitemid 30504977)
    • (1999) IEEE Transactions on Nuclear Science , vol.46 , Issue.3 , pp. 603-607
    • Huang, S.-C.1
  • 17
    • 0033983926 scopus 로고    scopus 로고
    • Performance evaluation of PET scanners: Testing of geometric arc correction by off-centre uniformity measurement
    • R. Buchert, K. H. Bohuslavizki, H. Fricke et aI., "Performance evaluation of PET scanners: testing of geometric arc correction by offcentre uniformity measurement," EurJ Nucl Med, vol.27, no. 1, pp. 8390, Jan, 2000. (Pubitemid 30097265)
    • (2000) European Journal of Nuclear Medicine , vol.27 , Issue.1 , pp. 83-90
    • Buchert, R.1    Bohuslavizki, K.H.2    Fricke, H.3    Mester, J.4    Clausen, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.