메뉴 건너뛰기




Volumn , Issue , 2008, Pages 3832-3835

PET alignment for small animal scanners based on capillary detection

Author keywords

[No Author keywords available]

Indexed keywords

ALIGNMENT PARAMETER; CALIBRATION PROCEDURE; COMPUTATIONAL EFFORT; DUAL-MODALITY SYSTEMS; GEOMETRIC CONFIGURATIONS; GEOMETRICAL RELATIONSHIP; GLASS CAPILLARIES; LABORATORY MATERIALS; LINE DETECTION; MOLECULAR IMAGING; NON-COPLANAR; POINT SOURCES; REGISTRATION PROCESS; SMALL ANIMAL; SMALL ANIMAL IMAGING; SPATIAL TRANSFORMATION; TRANSFORMATION PARAMETERS; TRIANGULAR GEOMETRY; VISUALIZATION AND ANALYSIS;

EID: 67649148584     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774117     Document Type: Conference Paper
Times cited : (4)

References (16)
  • 1
    • 0036093165 scopus 로고    scopus 로고
    • PET attenuation coefficients from CT images: Experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients
    • DOI 10.1007/s00259-002-0796-3
    • C. Burger, G. Goerres, S. Schoenes, A. Buck, A. H. Lonn, and G. K. Von Schulthess, "PET attenuation coefficients from CT images: experimental evaluation ofthe transformation of CT into PET 511-keV attenuation coefficients," Eur Nucl Med Mol Imaging, vol.29, pp. 922-927, Jul 2002. (Pubitemid 34671298)
    • (2002) European Journal of Nuclear Medicine , vol.29 , Issue.7 , pp. 922-927
    • Burger, C.1    Goerres, G.2    Schoenes, S.3    Buck, A.4    Lonn, A.5    Von Schulthess, G.6
  • 2
    • 0031791001 scopus 로고    scopus 로고
    • Attenuation correction for a combined 3D PET/CT scanner
    • Oct
    • P. Kinahan, D. W. Townsend, T. Beyer, and D. Sashin, "Attenuation correction for a combined 3D PET/CT scanner," Med Phys, vol.25, pp. 2046-2053, Oct 1998.
    • (1998) Med Phys , vol.25 , pp. 2046-2053
    • Kinahan, P.1    Townsend, D.W.2    Beyer, T.3    Sashin, D.4
  • 3
    • 53149149849 scopus 로고    scopus 로고
    • Role of fluorodeoxyglucose-PET versus fluorodeoxyglucosePET/ computed tomography in detection of unknown primary tumor: A meta-analysis of the literature
    • Sep
    • M. J. Dong, K. Zhao, X. T. Lin, J. Zhao, X. Ruan, and Z. F. Liu, "Role of fluorodeoxyglucose-PET versus fluorodeoxyglucosePET/ computed tomography in detection of unknown primary tumor: a meta-analysis of the literature," Nucl Med Commun, vol.29, pp. 791802, Sep 2008.
    • (2008) Nucl Med Commun , vol.29 , pp. 791-802
    • Dong, M.J.1    Zhao, K.2    Lin, X.T.3    Zhao, J.4    Ruan, X.5    Liu, Z.F.6
  • 4
    • 33645768397 scopus 로고    scopus 로고
    • False-positive FDG PET uptake-the role of PET/CT
    • May
    • S.1. Rosenbaum, T. Lind, G. Antoch, and A. Bockisch, "False-positive FDG PET uptake-the role of PET/CT," Eur Radiol, vol.16, pp. 105465, May 2006.
    • (2006) Eur Radiol , vol.16 , pp. 1054-1065
    • Rosenbaum, S.J.1    Lind, T.2    Antoch, G.3    Bockisc, A.4
  • 7
    • 32544449487 scopus 로고    scopus 로고
    • A method of image registration for small animal, multi-modality imaging
    • Jan 21 2006
    • P. Chow, D. B. Stout, E. Komisopoulou, and A. F. Chatziioannou, "A method of image registration for small animal, multi-modality imaging," Phys Med Biol, vol.51, pp. 379-390, Jan 21 2006.
    • Phys Med Biol. , vol.51 , pp. 379-390
    • Chow, P.1    Stout, D.B.2    Komisopoulou, E.3    Chatziioannou, A.F.4
  • 10
    • 34250327539 scopus 로고    scopus 로고
    • A microPET/CT system for invivo small animal imaging
    • DOI 10.1088/0031-9155/52/13/015, PII S0031915507372965, 015
    • H. Liang, Y. Yang, K. Yang, Y. Wu,J. M. Boone, and S. R. Cherry, "A microPET/CT system for in vivo small animal imaging," Phys Med BiOl, vol.52, pp. 3881-3894, Jul 7 2007. (Pubitemid 46908601)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.13 , pp. 3881-3894
    • Liang, H.1    Yang, Y.2    Yang, K.3    Wu, Y.4    Boone, J.M.5    Cherry, S.R.6
  • 12
    • 0035437717 scopus 로고    scopus 로고
    • The distribution of target registration error in rigid-body point-based registration
    • DOI 10.1109/42.952729, PII S0278006201086633
    • J. M. Fitzpatrick and J. B. West, "The distribution of target registration error in rigid-body point-based registration," Medical Imaging, IEEE Transactions on, vol. 20, pp. 917-927,2001. (Pubitemid 32992594)
    • (2001) IEEE Transactions on Medical Imaging , vol.20 , Issue.9 , pp. 917-927
    • Fitzpatrick, J.M.1    West, J.B.2
  • 14
    • 34247229328 scopus 로고    scopus 로고
    • Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner
    • Y. Wang, J. Seidel, B. M. W. Tsui, J. J. Vaquero, and M. G. Pomper, "Performance Evaluation of the GE Healthcare eXplore VISTA DualRing Small-Animal PET Scanner," J Nucl Med, vol.47, pp. 1891-1900,2006. (Pubitemid 47545013)
    • (2006) Journal of Nuclear Medicine , vol.47 , Issue.11 , pp. 1891-1900
    • Wang, Y.1    Seidel, J.2    Tsui, B.M.W.3    Vaquero, J.J.4    Pomper, M.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.