-
1
-
-
69949147783
-
-
Van Beusekom HM, Regar E, Peters I, Van der Giessen WJ. Long-term effects of endovascular radiation after balloon angioplasty: assessment by OCT and histology. In: Optical Coherence Tomography in Cardiovascular Research. Regar E, van Leeuwen AMGJ, Serruys PW (Eds). Informa Healthcare, London, UK (2007)
-
Van Beusekom HM, Regar E, Peters I, Van der Giessen WJ. Long-term effects of endovascular radiation after balloon angioplasty: assessment by OCT and histology. In: Optical Coherence Tomography in Cardiovascular Research. Regar E, van Leeuwen AMGJ, Serruys PW (Eds). Informa Healthcare, London, UK (2007)
-
-
-
-
2
-
-
0037422532
-
Quantification of macrophage content in atherosclerotic plaques by optical coherence tomography
-
Tearney GJ, Yabushita H, Houser SL et al. Quantification of macrophage content in atherosclerotic plaques by optical coherence tomography. Circulation 107(1), 113-119 (2003).
-
(2003)
Circulation
, vol.107
, Issue.1
, pp. 113-119
-
-
Tearney, G.J.1
Yabushita, H.2
Houser, S.L.3
-
3
-
-
2442596238
-
Optical coherence tomography
-
Regar E, Schaar JA, Mont E, Virmani R, Serruys PW. Optical coherence tomography. Cardiovasc. Radiat. Med. 4(4), 198-204 (2003).
-
(2003)
Cardiovasc. Radiat. Med
, vol.4
, Issue.4
, pp. 198-204
-
-
Regar, E.1
Schaar, J.A.2
Mont, E.3
Virmani, R.4
Serruys, P.W.5
-
4
-
-
20144388778
-
In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography
-
Jang IK, Tearney GJ, MacNeill B et al. In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography. Circulation 111(12), 1551-1555 (2005).
-
(2005)
Circulation
, vol.111
, Issue.12
, pp. 1551-1555
-
-
Jang, I.K.1
Tearney, G.J.2
MacNeill, B.3
-
5
-
-
33746413498
-
Optical coherence tomography for imaging the vulnerable plaque
-
Tearney GJ, Jang IK, Bouma BE. Optical coherence tomography for imaging the vulnerable plaque. J. Biomed. Opt. 11(2), 021002 (2006).
-
(2006)
J. Biomed. Opt
, vol.11
, Issue.2
, pp. 021002
-
-
Tearney, G.J.1
Jang, I.K.2
Bouma, B.E.3
-
6
-
-
33745711965
-
Sirolimus-eluting stent fracture with thrombus, visualization by optical coherence tomography
-
Shite J, Matsumoto D, Yokoyama M. Sirolimus-eluting stent fracture with thrombus, visualization by optical coherence tomography. Eur. Heart J. 27(12), 1389 (2006).
-
(2006)
Eur. Heart J
, vol.27
, Issue.12
, pp. 1389
-
-
Shite, J.1
Matsumoto, D.2
Yokoyama, M.3
-
7
-
-
40749148045
-
Intravascular optical coherence tomography: Optimisation of image acquisition and quantitative assessment of stent strut apposition
-
Tanigawa J, Barlis P, Di Mario C. Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition. EuroIntervention 3, 128-136 (2007).
-
(2007)
EuroIntervention
, vol.3
, pp. 128-136
-
-
Tanigawa, J.1
Barlis, P.2
Di Mario, C.3
-
8
-
-
34147221278
-
Do unapposed stent struts endothelialise? In vivo demonstration with optical coherence tomography
-
Tanigawa J, Barlis P, Di Mario C. Do unapposed stent struts endothelialise? In vivo demonstration with optical coherence tomography. Heart 93(3), 378 (2007).
-
(2007)
Heart
, vol.93
, Issue.3
, pp. 378
-
-
Tanigawa, J.1
Barlis, P.2
Di Mario, C.3
-
9
-
-
38749093780
-
Does optical coherence tomography identify arterial healing after stenting? An in vivo comparison with histology, on a rabbit carotid model
-
Prati F, Zimarino M, Stabile E et al. Does optical coherence tomography identify arterial healing after stenting? An in vivo comparison with histology, on a rabbit carotid model. Heart 94, 217-221 (2008).
-
(2008)
Heart
, vol.94
, pp. 217-221
-
-
Prati, F.1
Zimarino, M.2
Stabile, E.3
-
10
-
-
34147135208
-
Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation
-
Takano M, Inami S, Jang IK et al. Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am. J. Cardiol. 99(8), 1033-1038 (2007).
-
(2007)
Am. J. Cardiol
, vol.99
, Issue.8
, pp. 1033-1038
-
-
Takano, M.1
Inami, S.2
Jang, I.K.3
-
11
-
-
55749113734
-
Optical coherence tomography to assess malapposition in overlapping drug-eluting stents
-
Tanigawa J, Barlis P, Dimopoulos K, Di Mario C. Optical coherence tomography to assess malapposition in overlapping drug-eluting stents. EuroIntervention 3(13), 580-583 (2008).
-
(2008)
EuroIntervention
, vol.3
, Issue.13
, pp. 580-583
-
-
Tanigawa, J.1
Barlis, P.2
Dimopoulos, K.3
Di Mario, C.4
-
12
-
-
49749105926
-
Optical coherence tomography assessment of vulnerable plaque rupture: Predilection for the plaque 'shoulder'
-
Barlis P, Serruys PW, DeVries A, Regar E. Optical coherence tomography assessment of vulnerable plaque rupture: predilection for the plaque 'shoulder'. Eur. Heart J. 29(16), 2023 (2008).
-
(2008)
Eur. Heart J
, vol.29
, Issue.16
, pp. 2023
-
-
Barlis, P.1
Serruys, P.W.2
DeVries, A.3
Regar, E.4
-
13
-
-
50949093680
-
Assessment of culprit and remote coronary narrowings using optical coherence tomography with long-term outcomes
-
Barlis P, Serruys PW, Gonzalo N, van der Giessen WJ, de Jaegere PJ, Regar E. Assessment of culprit and remote coronary narrowings using optical coherence tomography with long-term outcomes. Am. J. Cardiol. 102(4), 391-395 (2008).
-
(2008)
Am. J. Cardiol
, vol.102
, Issue.4
, pp. 391-395
-
-
Barlis, P.1
Serruys, P.W.2
Gonzalo, N.3
van der Giessen, W.J.4
de Jaegere, P.J.5
Regar, E.6
-
14
-
-
34248219973
-
Pathological correlates of late drug-eluting stent thrombosis: Strut coverage as a marker of endothelialization
-
Finn AV, Joner M, Nakazawa G et al. Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115(18), 2435-2441 (2007).
-
(2007)
Circulation
, vol.115
, Issue.18
, pp. 2435-2441
-
-
Finn, A.V.1
Joner, M.2
Nakazawa, G.3
-
15
-
-
69949151589
-
-
Michelson AA, Morley EW. On the relative motion of the earth and the luminiferous aether. Am. J. Sci. S5(151), 449-463 (1887).
-
Michelson AA, Morley EW. On the relative motion of the earth and the luminiferous aether. Am. J. Sci. S5(151), 449-463 (1887).
-
-
-
-
16
-
-
0027934282
-
Optical-coherence tomography of a dense tissue: Statistics of attenuation and backscattering
-
Schmitt JM, Knuttel A, Yadlowsky M, Eckhaus MA. Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering. Phys. Med. Biol. 39(10), 1705-1720 (1994).
-
(1994)
Phys. Med. Biol
, vol.39
, Issue.10
, pp. 1705-1720
-
-
Schmitt, J.M.1
Knuttel, A.2
Yadlowsky, M.3
Eckhaus, M.A.4
-
17
-
-
0033327503
-
Optical coherence tomography (OCT): A review
-
Schmitt JM. Optical coherence tomography (OCT): a review. IEEE J. Sel. Top. Quant. Elec. 5(4), 1205-1215 (1999).
-
(1999)
IEEE J. Sel. Top. Quant. Elec
, vol.5
, Issue.4
, pp. 1205-1215
-
-
Schmitt, J.M.1
-
18
-
-
0032620384
-
Power-efficient nonreciprocal interferometer and linear-scanning fiber-optic catheter for optical coherence tomography
-
Bouma BE, Tearney GJ. Power-efficient nonreciprocal interferometer and linear-scanning fiber-optic catheter for optical coherence tomography. Opt. Lett. 24(8), 531-533 (1999).
-
(1999)
Opt. Lett
, vol.24
, Issue.8
, pp. 531-533
-
-
Bouma, B.E.1
Tearney, G.J.2
-
19
-
-
44149100010
-
From bench to bedside
-
Prati F, Cera M, Ramazzotti V et al. From bench to bedside. Circ. J. 72(5), 839-843 (2008).
-
(2008)
Circ. J
, vol.72
, Issue.5
, pp. 839-843
-
-
Prati, F.1
Cera, M.2
Ramazzotti, V.3
-
20
-
-
50849084024
-
Stent strut apposition in complex lesions using optical coherence tomography
-
Tanigawa J, Barlis P, Kaplan S, Goktekin O, Di Mario C. Stent strut apposition in complex lesions using optical coherence tomography. Am. J. Cardiol. 98(8), M97 (2006).
-
(2006)
Am. J. Cardiol
, vol.98
, Issue.8
-
-
Tanigawa, J.1
Barlis, P.2
Kaplan, S.3
Goktekin, O.4
Di Mario, C.5
-
21
-
-
39549105785
-
Long-term follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: Do uncovered struts persist?
-
Takano M, Yamamoto M, Inami S et al. Long-term follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: do uncovered struts persist? J. Am. Coll. Cardiol. 51(9), 968-969 (2008).
-
(2008)
J. Am. Coll. Cardiol
, vol.51
, Issue.9
, pp. 968-969
-
-
Takano, M.1
Yamamoto, M.2
Inami, S.3
-
22
-
-
41949094809
-
Safety and feasibility of a new non-occlusive technique for facilitated intracoronary optical coherence tomography (OCT) acquisition in various clinical and anatomical scenarios
-
Prati F, Cera M, Ramazzotti V, Imola F, Giudice R, Albertucci M. Safety and feasibility of a new non-occlusive technique for facilitated intracoronary optical coherence tomography (OCT) acquisition in various clinical and anatomical scenarios. EuroIntervention 3(11), 365-370 (2007).
-
(2007)
EuroIntervention
, vol.3
, Issue.11
, pp. 365-370
-
-
Prati, F.1
Cera, M.2
Ramazzotti, V.3
Imola, F.4
Giudice, R.5
Albertucci, M.6
-
23
-
-
34548329438
-
Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: Evaluated by optical coherence tomography
-
Matsumoto D, Shite J, Shinke T et al. Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur. Heart J. 28(8), 961-967 (2007).
-
(2007)
Eur. Heart J
, vol.28
, Issue.8
, pp. 961-967
-
-
Matsumoto, D.1
Shite, J.2
Shinke, T.3
-
24
-
-
42549117199
-
Neointimal coverage of bare metal and sirolimus-eluting stents evaluated with optical coherence tomography
-
Chen BX, Ma FY, Wei L et al. Neointimal coverage of bare metal and sirolimus-eluting stents evaluated with optical coherence tomography. Heart 94, 566-570 (2008).
-
(2008)
Heart
, vol.94
, pp. 566-570
-
-
Chen, B.X.1
Ma, F.Y.2
Wei, L.3
-
25
-
-
34548161312
-
Assessment of culprit lesion morphology in acute myocardial infarction: Ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy
-
Kubo T, Imanishi T, Takarada S et al. Assessment of culprit lesion morphology in acute myocardial infarction: ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy. J. Am. Coll. Cardiol. 50(10), 933-939 (2007).
-
(2007)
J. Am. Coll. Cardiol
, vol.50
, Issue.10
, pp. 933-939
-
-
Kubo, T.1
Imanishi, T.2
Takarada, S.3
-
26
-
-
39849106395
-
Heavily calcified coronary lesions preclude strut apposition despite high pressure balloon dilatation and rotational atherectomy: In-vivo demonstration with optical coherence tomography
-
Tanigawa J, Barlis P, Di Mario C. Heavily calcified coronary lesions preclude strut apposition despite high pressure balloon dilatation and rotational atherectomy: in-vivo demonstration with optical coherence tomography. Circ. J. 72(1), 157-160 (2008).
-
(2008)
Circ. J
, vol.72
, Issue.1
, pp. 157-160
-
-
Tanigawa, J.1
Barlis, P.2
Di Mario, C.3
-
27
-
-
41949137318
-
Safety and feasibility of an intravascular optical coherence tomography image wire system in the clinical setting
-
Yamaguchi T, Terashima M, Akasaka T et al. Safety and feasibility of an intravascular optical coherence tomography image wire system in the clinical setting. Am. J. Cardiol. 101(5), 562-567 (2008).
-
(2008)
Am. J. Cardiol
, vol.101
, Issue.5
, pp. 562-567
-
-
Yamaguchi, T.1
Terashima, M.2
Akasaka, T.3
-
28
-
-
50349091748
-
Images in cardiovascular medicine. Catastrophic thrombus formation during optical coherence tomography
-
Kim JS, Choi EY, Choi D, Jang Y. Images in cardiovascular medicine. Catastrophic thrombus formation during optical coherence tomography. Circulation 118(6), E101-E102 (2008).
-
(2008)
Circulation
, vol.118
, Issue.6
-
-
Kim, J.S.1
Choi, E.Y.2
Choi, D.3
Jang, Y.4
-
29
-
-
0022384855
-
In-hospital morbidity and mortality in patients undergoing elective coronary angioplasty
-
Bredlau CE, Roubin GS, Leimgruber PP, Douglas JS Jr, King SB 3rd, Gruentzig AR. In-hospital morbidity and mortality in patients undergoing elective coronary angioplasty. Circulation 72(5), 1044-1052 (1985).
-
(1985)
Circulation
, vol.72
, Issue.5
, pp. 1044-1052
-
-
Bredlau, C.E.1
Roubin, G.S.2
Leimgruber, P.P.3
Douglas Jr, J.S.4
King 3rd, S.B.5
Gruentzig, A.R.6
-
30
-
-
0020660871
-
Percutaneous transluminal coronary angioplasty: Report of complications from the National Heart, Lung, and Blood Institute PTCA Registry
-
Dorros G, Cowley MJ, Simpson J et al. Percutaneous transluminal coronary angioplasty: report of complications from the National Heart, Lung, and Blood Institute PTCA Registry. Circulation 67(4), 723-730 (1983).
-
(1983)
Circulation
, vol.67
, Issue.4
, pp. 723-730
-
-
Dorros, G.1
Cowley, M.J.2
Simpson, J.3
-
31
-
-
0018779142
-
Complications of coronary arteriography from the Collaborative Study of Coronary Artery Surgery (CASS)
-
Davis K, Kennedy JW, Kemp HG Jr, Judkins MP, Gosselin AJ, Killip T. Complications of coronary arteriography from the Collaborative Study of Coronary Artery Surgery (CASS). Circulation 59(6), 1105-1112 (1979).
-
(1979)
Circulation
, vol.59
, Issue.6
, pp. 1105-1112
-
-
Davis, K.1
Kennedy, J.W.2
Kemp Jr, H.G.3
Judkins, M.P.4
Gosselin, A.J.5
Killip, T.6
-
32
-
-
0021280590
-
Ventricular arrhythmias during coronary angiography in patients with angina pectoris or chest pain syndromes
-
Nishimura RA, Holmes DR Jr, McFarland TM, Smith HC, Bove AA. Ventricular arrhythmias during coronary angiography in patients with angina pectoris or chest pain syndromes. Am. J. Cardiol. 53(11), 1496-1499 (1984).
-
(1984)
Am. J. Cardiol
, vol.53
, Issue.11
, pp. 1496-1499
-
-
Nishimura, R.A.1
Holmes Jr, D.R.2
McFarland, T.M.3
Smith, H.C.4
Bove, A.A.5
-
33
-
-
0028335754
-
Arrhythmogenic in?uence of intracoronary thrombosis during acute myocardial ischemia
-
Goldstein JA, Butterfield MC, Ohnishi Y, Shelton TJ, Corr PB. Arrhythmogenic in?uence of intracoronary thrombosis during acute myocardial ischemia. Circulation 90(1), 139-147 (1994).
-
(1994)
Circulation
, vol.90
, Issue.1
, pp. 139-147
-
-
Goldstein, J.A.1
Butterfield, M.C.2
Ohnishi, Y.3
Shelton, T.J.4
Corr, P.B.5
-
34
-
-
33748977858
-
Tachyarrhythmias in percutaneous coronary interventions
-
Gorenek B. Tachyarrhythmias in percutaneous coronary interventions. J. Electrocardiol. 39(4), E411-E415 (2006).
-
(2006)
J. Electrocardiol
, vol.39
, Issue.4
-
-
Gorenek, B.1
-
35
-
-
0036126508
-
Mechanisms of ventricular fibrillation during coronary angioplasty: Increased incidence for the small orifice caliber of the right coronary artery
-
Huang JL, Ting CT, Chen YT, Chen SA. Mechanisms of ventricular fibrillation during coronary angioplasty: increased incidence for the small orifice caliber of the right coronary artery. Int. J. Cardiol. 82(3), 221-228 (2002).
-
(2002)
Int. J. Cardiol
, vol.82
, Issue.3
, pp. 221-228
-
-
Huang, J.L.1
Ting, C.T.2
Chen, Y.T.3
Chen, S.A.4
-
36
-
-
0025016934
-
Ventricular fibrillation during coronary angiography: Reduced incidence with nonionic contrast media
-
Missri J, Jeresaty RM. Ventricular fibrillation during coronary angiography: reduced incidence with nonionic contrast media. Cathet. Cardiovasc. Diagn. 19(1), 4-7 (1990).
-
(1990)
Cathet. Cardiovasc. Diagn
, vol.19
, Issue.1
, pp. 4-7
-
-
Missri, J.1
Jeresaty, R.M.2
-
37
-
-
0029417971
-
Contrast-medium-induced ventricular fibrillation: Arrhythmogenic mechanisms and the role of antiarrhythmic drugs in dogs
-
Pedersen HK, Jacobsen EA, Mortensen E, Refsum H. Contrast-medium-induced ventricular fibrillation: arrhythmogenic mechanisms and the role of antiarrhythmic drugs in dogs. Acad. Radiol. 2(12), 1082-1088 (1995).
-
(1995)
Acad. Radiol
, vol.2
, Issue.12
, pp. 1082-1088
-
-
Pedersen, H.K.1
Jacobsen, E.A.2
Mortensen, E.3
Refsum, H.4
-
38
-
-
0021807318
-
Ventricular fibrillation during coronary angiography: Association with potassium-containing glyceryl trinitrate
-
Quigley PJ, Maurer BJ. Ventricular fibrillation during coronary angiography: association with potassium-containing glyceryl trinitrate. Am. J. Cardiol. 56(1), 191 (1985).
-
(1985)
Am. J. Cardiol
, vol.56
, Issue.1
, pp. 191
-
-
Quigley, P.J.1
Maurer, B.J.2
-
39
-
-
0027121755
-
High-osmolality and low-osmolality contrast agents
-
Rudoff J, Phillips L. High-osmolality and low-osmolality contrast agents. N. Engl. J. Med. 327(3), 203-204 (1992).
-
(1992)
N. Engl. J. Med
, vol.327
, Issue.3
, pp. 203-204
-
-
Rudoff, J.1
Phillips, L.2
-
41
-
-
0024360951
-
Low-osmolality contrast media-induced ventricular fibrillation
-
Hayakawa K, Yamashita K. Low-osmolality contrast media-induced ventricular fibrillation. Invest. Radiol. 24(4), 298-301 (1989).
-
(1989)
Invest. Radiol
, vol.24
, Issue.4
, pp. 298-301
-
-
Hayakawa, K.1
Yamashita, K.2
-
42
-
-
0022444931
-
Incidence of fibrillation with dilute contrast media for intra-arterial coronary digital subtraction angiography
-
Morris TW, Ventura J. Incidence of fibrillation with dilute contrast media for intra-arterial coronary digital subtraction angiography. Invest. Radiol. 21(5), 416-418 (1986).
-
(1986)
Invest. Radiol
, vol.21
, Issue.5
, pp. 416-418
-
-
Morris, T.W.1
Ventura, J.2
-
43
-
-
40049097128
-
Incidence of ventricular fibrillation during left coronary arteriography in pigs: Comparison of a solution of the nonionic dimer iodixanol with solutions of five different nonionic monomers
-
Chai CM, Karlsson JO, Almen T. Incidence of ventricular fibrillation during left coronary arteriography in pigs: comparison of a solution of the nonionic dimer iodixanol with solutions of five different nonionic monomers. Acta Radiol. 49(2), 150-156 (2008).
-
(2008)
Acta Radiol
, vol.49
, Issue.2
, pp. 150-156
-
-
Chai, C.M.1
Karlsson, J.O.2
Almen, T.3
-
44
-
-
0030704640
-
Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions
-
Albiero R, Rau T, Schluter M et al. Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions. Circulation 96(9), 2997-3005 (1997).
-
(1997)
Circulation
, vol.96
, Issue.9
, pp. 2997-3005
-
-
Albiero, R.1
Rau, T.2
Schluter, M.3
-
45
-
-
0034088729
-
Predictors of event-free survival after repeat intracoronary procedure for in-stent restenosis; study with angiographic and intravascular ultrasound imaging
-
Schiele F, Meneveau N, Seronde MF, Deforet MF, Gupta S, Bassand JP. Predictors of event-free survival after repeat intracoronary procedure for in-stent restenosis; study with angiographic and intravascular ultrasound imaging. Eur. Heart J. 21(9), 754-762 (2000).
-
(2000)
Eur. Heart J
, vol.21
, Issue.9
, pp. 754-762
-
-
Schiele, F.1
Meneveau, N.2
Seronde, M.F.3
Deforet, M.F.4
Gupta, S.5
Bassand, J.P.6
-
46
-
-
10744222703
-
Optimal final lumen area and predictors of target lesion revascularization after stent implantation in small coronary arteries
-
Iakovou I, Mintz GS, Dangas G et al. Optimal final lumen area and predictors of target lesion revascularization after stent implantation in small coronary arteries. Am. J. Cardiol. 92(10), 1171-1176 (2003).
-
(2003)
Am. J. Cardiol
, vol.92
, Issue.10
, pp. 1171-1176
-
-
Iakovou, I.1
Mintz, G.S.2
Dangas, G.3
-
47
-
-
20344387235
-
Underexpansion of sirolimus-eluting stents: Incidence and relationship to delivery pressure
-
Cheneau E, Satler LF, Escolar E et al. Underexpansion of sirolimus-eluting stents: incidence and relationship to delivery pressure. Catheter Cardiovasc. Interv. 65(2), 222-226 (2005).
-
(2005)
Catheter Cardiovasc. Interv
, vol.65
, Issue.2
, pp. 222-226
-
-
Cheneau, E.1
Satler, L.F.2
Escolar, E.3
-
48
-
-
12144286893
-
Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis
-
Fujii K, Mintz GS, Kobayashi Y et al. Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis. Circulation 109(9), 1085-1088 (2004).
-
(2004)
Circulation
, vol.109
, Issue.9
, pp. 1085-1088
-
-
Fujii, K.1
Mintz, G.S.2
Kobayashi, Y.3
-
49
-
-
35148829522
-
Coronary bioabsorbable magnesium stent: 15-month intravascular ultrasound and optical coherence tomography findings
-
Barlis P, Tanigawa J, Di Mario C. Coronary bioabsorbable magnesium stent: 15-month intravascular ultrasound and optical coherence tomography findings. Eur. Heart J. 28(19), 2319 (2007).
-
(2007)
Eur. Heart J
, vol.28
, Issue.19
, pp. 2319
-
-
Barlis, P.1
Tanigawa, J.2
Di Mario, C.3
-
50
-
-
33644861134
-
Late stent malapposition after drug-eluting stent implantation: An intravascular ultrasound analysis with long-term follow-up
-
Hong MK, Mintz GS, Lee CW et al. Late stent malapposition after drug-eluting stent implantation: an intravascular ultrasound analysis with long-term follow-up. Circulation 113(3), 414-419 (2006).
-
(2006)
Circulation
, vol.113
, Issue.3
, pp. 414-419
-
-
Hong, M.K.1
Mintz, G.S.2
Lee, C.W.3
-
51
-
-
20044363609
-
Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: Insights from the randomized TAXUS II trial
-
Tanabe K, Serruys PW, Degertekin M et al. Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: insights from the randomized TAXUS II trial. Circulation 111(7), 900-905 (2005).
-
(2005)
Circulation
, vol.111
, Issue.7
, pp. 900-905
-
-
Tanabe, K.1
Serruys, P.W.2
Degertekin, M.3
-
52
-
-
64849091370
-
The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography
-
DOI:10.1016/j.ijcard.2008.05.069 , Epub ahead of print
-
Tanigawa J, Barlis P, Dimopoulos K, Dalby M, Moore P, Di Mario C. The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int. J. Cardiol. DOI:10.1016/j.ijcard.2008.05.069 (2008) (Epub ahead of print).
-
(2008)
Int. J. Cardiol
-
-
Tanigawa, J.1
Barlis, P.2
Dimopoulos, K.3
Dalby, M.4
Moore, P.5
Di Mario, C.6
-
53
-
-
29644444799
-
Images in cardiology. Acute recoil in sirolimus eluting stent: Real time, in vivo assessment with optical coherence tomography
-
Regar E, Schaar J, Serruys PW. Images in cardiology. Acute recoil in sirolimus eluting stent: real time, in vivo assessment with optical coherence tomography. Heart 92(1), 123 (2006).
-
(2006)
Heart
, vol.92
, Issue.1
, pp. 123
-
-
Regar, E.1
Schaar, J.2
Serruys, P.W.3
-
54
-
-
50849099498
-
A novel approach for quantitative analysis of intracoronary optical coherence tomography: High inter-observer agreement with computer-assisted contour detection
-
Tanimoto S, Rodriguez-Granillo G, Barlis P et al. A novel approach for quantitative analysis of intracoronary optical coherence tomography: high inter-observer agreement with computer-assisted contour detection. Catheter Cardiovasc. Interv. 72(2), 228-235 (2008).
-
(2008)
Catheter Cardiovasc. Interv
, vol.72
, Issue.2
, pp. 228-235
-
-
Tanimoto, S.1
Rodriguez-Granillo, G.2
Barlis, P.3
-
55
-
-
34250835092
-
Vascular responses to drug eluting stents: Importance of delayed healing
-
Finn AV, Nakazawa G, Joner M et al. Vascular responses to drug eluting stents: importance of delayed healing. Arterioscler. Thromb. Vasc. Biol. 27(7), 1500-1510 (2007).
-
(2007)
Arterioscler. Thromb. Vasc. Biol
, vol.27
, Issue.7
, pp. 1500-1510
-
-
Finn, A.V.1
Nakazawa, G.2
Joner, M.3
-
56
-
-
33745233024
-
Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk
-
Joner M, Finn AV, Farb A et al. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J. Am. Coll. Cardiol. 48(1), 193-202 (2006).
-
(2006)
J. Am. Coll. Cardiol
, vol.48
, Issue.1
, pp. 193-202
-
-
Joner, M.1
Finn, A.V.2
Farb, A.3
-
57
-
-
34547669112
-
Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation
-
Lee SH, Park JS, Shin DG et al. Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation. Am. J. Cardiol. 100(4), 627-630 (2007).
-
(2007)
Am. J. Cardiol
, vol.100
, Issue.4
, pp. 627-630
-
-
Lee, S.H.1
Park, J.S.2
Shin, D.G.3
-
58
-
-
67649870626
-
The use of intra-coronary optical coherence tomography for the assessment of sirolimus-eluting stent fracture
-
DOI: 10.1016/ j.ijcard.2008.04.076 , Epub ahead of print
-
Barlis P, Sianos G, Ferrante G, Del Furia F, D'Souza S, Di Mario C. The use of intra-coronary optical coherence tomography for the assessment of sirolimus-eluting stent fracture. Int. J. Cardiol. DOI: 10.1016/ j.ijcard.2008.04.076 (2008) (Epub ahead of print).
-
(2008)
Int. J. Cardiol
-
-
Barlis, P.1
Sianos, G.2
Ferrante, G.3
Del Furia, F.4
D'Souza, S.5
Di Mario, C.6
-
59
-
-
69949182197
-
Acute optical coherence tomography findings after stenting
-
Eds, Informa Healthcare, London, UK 2007
-
Surmely J, Takeda Y, Ita T, Suzuki T. Acute optical coherence tomography findings after stenting. In: Optical Coherence Tomography in Cardiovascular Research. Regar E, van Leeuwen AMGJ, Serruys PW (Eds). Informa Healthcare, London, UK (2007).
-
Optical Coherence Tomography in Cardiovascular Research
-
-
Surmely, J.1
Takeda, Y.2
Ita, T.3
Suzuki, T.4
-
60
-
-
55749101228
-
Paclitaxel-eluting stent restenosis shows three-layer appearance by optical coherence tomography
-
Tanimoto T, Aoki J, Serruys PW, Regar E. Paclitaxel-eluting stent restenosis shows three-layer appearance by optical coherence tomography. EuroIntervention 1(4), 484 (2006).
-
(2006)
EuroIntervention
, vol.1
, Issue.4
, pp. 484
-
-
Tanimoto, T.1
Aoki, J.2
Serruys, P.W.3
Regar, E.4
-
61
-
-
33644874009
-
Images in cardiovascular medicine. Optical coherence tomography findings at 5-year follow-up after coronary stent implantation
-
Regar E, van Beusekom HM, van der Giessen WJ, Serruys PW. Images in cardiovascular medicine. Optical coherence tomography findings at 5-year follow-up after coronary stent implantation. Circulation 112(23), E345-E346 (2005).
-
(2005)
Circulation
, vol.112
, Issue.23
-
-
Regar, E.1
van Beusekom, H.M.2
van der Giessen, W.J.3
Serruys, P.W.4
-
62
-
-
0037369227
-
Evaluation of intracoronary stenting by intravascular optical coherence tomography
-
Bouma BE, Tearney GJ, Yabushita H et al. Evaluation of intracoronary stenting by intravascular optical coherence tomography. Heart 89(3), 317-320 (2003).
-
(2003)
Heart
, vol.89
, Issue.3
, pp. 317-320
-
-
Bouma, B.E.1
Tearney, G.J.2
Yabushita, H.3
-
63
-
-
0032192119
-
Long-term endothelial dysfunction is more pronounced after stenting than after balloon angioplasty in porcine coronary arteries
-
van Beusekom HM, Whelan DM, Hofma SH et al. Long-term endothelial dysfunction is more pronounced after stenting than after balloon angioplasty in porcine coronary arteries. J. Am. Coll. Cardiol. 32(4), 1109-1117 (1998).
-
(1998)
J. Am. Coll. Cardiol
, vol.32
, Issue.4
, pp. 1109-1117
-
-
van Beusekom, H.M.1
Whelan, D.M.2
Hofma, S.H.3
-
64
-
-
63149197754
-
-
Barlis P, Di Mario C, Van Beusekom HM, Gonzalo N, Regar E. Novelties in cardiac imaging: Optical coherence tomography. EuroIntervention 4(Suppl. C), C22-C26 (2008).
-
Barlis P, Di Mario C, Van Beusekom HM, Gonzalo N, Regar E. Novelties in cardiac imaging: Optical coherence tomography. EuroIntervention 4(Suppl. C), C22-C26 (2008).
-
-
-
-
65
-
-
34548308831
-
Drug-eluting stents show delayed healing: Paclitaxel more pronounced than sirolimus
-
van Busker HM, Saia F, Zindler JD et al. Drug-eluting stents show delayed healing: paclitaxel more pronounced than sirolimus. Eur. Heart J. 28(8), 974-979 (2007).
-
(2007)
Eur. Heart J
, vol.28
, Issue.8
, pp. 974-979
-
-
van Busker, H.M.1
Saia, F.2
Zindler, J.D.3
-
66
-
-
34250674779
-
Assessment of blood vessel mimics with optical coherence tomography
-
Bonnema GT, Cardinal KO, McNally JB, Williams SK, Barton JK. Assessment of blood vessel mimics with optical coherence tomography. J. Biomed. Opt. 12(2), 024018 (2007).
-
(2007)
J. Biomed. Opt
, vol.12
, Issue.2
, pp. 024018
-
-
Bonnema, G.T.1
Cardinal, K.O.2
McNally, J.B.3
Williams, S.K.4
Barton, J.K.5
-
67
-
-
2942738905
-
High-speed optical frequency-domain imaging
-
Yun SH, Tearney GJ, de Boer JF, Iftimia N, Bouma B. High-speed optical frequency-domain imaging. Opt. Express 11(22), 2953-2963 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.22
, pp. 2953-2963
-
-
Yun, S.H.1
Tearney, G.J.2
de Boer, J.F.3
Iftimia, N.4
Bouma, B.5
-
68
-
-
0001936881
-
Measurement of intraocular distances by backscattering spectral interferometry
-
Fercher AF, Hitzenberger CK, Kamp G, Elzaiat SY. Measurement of intraocular distances by backscattering spectral interferometry. Opt. Commun. 117(1-2), 43-48 (1995).
-
(1995)
Opt. Commun
, vol.117
, Issue.1-2
, pp. 43-48
-
-
Fercher, A.F.1
Hitzenberger, C.K.2
Kamp, G.3
Elzaiat, S.Y.4
-
69
-
-
0000063301
-
Optical coherence tomography using a frequency-tunable optical source
-
Chinn SR, Swanson EA, Fujimoto JG. Optical coherence tomography using a frequency-tunable optical source. Opt. Lett. 22(5), 340-342 (1997).
-
(1997)
Opt. Lett
, vol.22
, Issue.5
, pp. 340-342
-
-
Chinn, S.R.1
Swanson, E.A.2
Fujimoto, J.G.3
-
70
-
-
4043126029
-
In vivo video rate optical coherence tomography
-
Rollins AM, Kulkarni MD, Yazdanfar S, Ung-arunyawee R, Izatt JA. In vivo video rate optical coherence tomography. Opt. Express 3(6), 219-229 (1998).
-
(1998)
Opt. Express
, vol.3
, Issue.6
, pp. 219-229
-
-
Rollins, A.M.1
Kulkarni, M.D.2
Yazdanfar, S.3
Ung-arunyawee, R.4
Izatt, J.A.5
-
71
-
-
0038618462
-
Performance of Fourier domain vs. time domain optical coherence tomography
-
Leitgeb R, Hitzenberger CK, Fercher AF. Performance of Fourier domain vs. time domain optical coherence tomography. Opt. Express 11(8), 889-894 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.8
, pp. 889-894
-
-
Leitgeb, R.1
Hitzenberger, C.K.2
Fercher, A.F.3
-
72
-
-
2942703878
-
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
-
Choma M, Sarunic M, Yang C, Izatt J. Sensitivity advantage of swept source and Fourier domain optical coherence tomography. Opt. Express 11(18), 2183-2189 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.18
, pp. 2183-2189
-
-
Choma, M.1
Sarunic, M.2
Yang, C.3
Izatt, J.4
-
73
-
-
0242301675
-
Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
-
de Boer JF, Cense B, Park BH, Pierce MC, Tearney GJ, Bouma BE. Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. Opt. Lett. 28(21), 2067-2069 (2003).
-
(2003)
Opt. Lett
, vol.28
, Issue.21
, pp. 2067-2069
-
-
de Boer, J.F.1
Cense, B.2
Park, B.H.3
Pierce, M.C.4
Tearney, G.J.5
Bouma, B.E.6
-
74
-
-
33845514512
-
Comprehensive volumetric optical microscopy in vivo
-
Yun SH, Tearney GJ, Vakoc BJ et al. Comprehensive volumetric optical microscopy in vivo. Nat. Med. 12(12), 1429-1433 (2006).
-
(2006)
Nat. Med
, vol.12
, Issue.12
, pp. 1429-1433
-
-
Yun, S.H.1
Tearney, G.J.2
Vakoc, B.J.3
-
75
-
-
33750506518
-
Buffered Fourier domain mode locking: Unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s
-
Huber R, Adler DC, Fujimoto JG. Buffered Fourier domain mode locking: unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s. Opt. Lett. 31(20), 2975-2977 (2006).
-
(2006)
Opt. Lett
, vol.31
, Issue.20
, pp. 2975-2977
-
-
Huber, R.1
Adler, D.C.2
Fujimoto, J.G.3
-
76
-
-
34247196842
-
Ultra-high-speed optical coherence tomography with a stretched pulse supercontinuum source
-
Moon S, Kim DY. Ultra-high-speed optical coherence tomography with a stretched pulse supercontinuum source. Opt. Express 14, 11575-11584 (2006).
-
(2006)
Opt. Express
, vol.14
, pp. 11575-11584
-
-
Moon, S.1
Kim, D.Y.2
-
77
-
-
33845726046
-
High-speed imaging of human retina in vivo with swept-source optical coherence tomography
-
Lim H, Mujat M, Kerbage C et al. High-speed imaging of human retina in vivo with swept-source optical coherence tomography. Opt. Express 14(26), 12902-12908 (2006).
-
(2006)
Opt. Express
, vol.14
, Issue.26
, pp. 12902-12908
-
-
Lim, H.1
Mujat, M.2
Kerbage, C.3
-
78
-
-
56049124296
-
Three-dimensional coronary artery microscopy by intracoronary optical frequency domain imaging
-
Tearney G, Waxman S, Shishkov M et al. Three-dimensional coronary artery microscopy by intracoronary optical frequency domain imaging. J. Am. Coll. Cardiol. Img 1, 752-761 (2008).
-
(2008)
J. Am. Coll. Cardiol. Img
, vol.1
, pp. 752-761
-
-
Tearney, G.1
Waxman, S.2
Shishkov, M.3
|