메뉴 건너뛰기




Volumn 96, Issue 9, 1997, Pages 2997-3005

Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions

Author keywords

Angiography; Coronary disease; Restenosis; Stents; Ultrasonics

Indexed keywords

ADULT; AGED; ANGIOGRAPHY; ARTERY DIAMETER; ARTICLE; COMPARATIVE STUDY; CORONARY ARTERY DISEASE; FEMALE; HUMAN; IMPLANTATION; INTRAVASCULAR ULTRASOUND; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RESTENOSIS; STENT; TREATMENT OUTCOME; ULTRASOUND;

EID: 0030704640     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.96.9.2997     Document Type: Article
Times cited : (97)

References (26)
  • 6
    • 0042037129 scopus 로고
    • Prevention of subacute occlusion after coronary stenting with ticlopidine regimen without intravascular ultrasound guided stenting
    • Abstract
    • Barragan P, Silvestri M, Sainsous J, Simeoni JB, Bayet G, Bouvier JL, Comet B. Prevention of subacute occlusion after coronary stenting with ticlopidine regimen without intravascular ultrasound guided stenting. J Am Coll Cardiol. 1995;25:182A. Abstract.
    • (1995) J Am Coll Cardiol , vol.25
    • Barragan, P.1    Silvestri, M.2    Sainsous, J.3    Simeoni, J.B.4    Bayet, G.5    Bouvier, J.L.6    Comet, B.7
  • 7
    • 0029984958 scopus 로고    scopus 로고
    • Intracoronary stenting without intravascular ultrasound guidance followed by antiplatelet therapy with aspirin alone in selected patients
    • Roy PR, Lowe HC, Walter BW, Barpon DW, Gavaghan TP, Morgan JJ. Intracoronary stenting without intravascular ultrasound guidance followed by antiplatelet therapy with aspirin alone in selected patients. Am J Cardiol. 1996;77:1105-1107.
    • (1996) Am J Cardiol , vol.77 , pp. 1105-1107
    • Roy, P.R.1    Lowe, H.C.2    Walter, B.W.3    Barpon, D.W.4    Gavaghan, T.P.5    Morgan, J.J.6
  • 9
    • 0001550541 scopus 로고    scopus 로고
    • Angiography versus intravascular ultrasound-directed stent placement
    • Abstract
    • Russo RJ, Teirstein PS, and the A.V.I.D. Investigators. Angiography versus intravascular ultrasound-directed stent placement. J Am Coll Cardiol. 1996;27:306A. Abstract.
    • (1996) J Am Coll Cardiol , vol.27
    • Russo, R.J.1    Teirstein, P.S.2
  • 10
    • 0342727883 scopus 로고    scopus 로고
    • Benefit of intracoronary ultrasound after angiographically optimal Palmaz-Schatz stent deployment
    • Abstract
    • Vardi GM, Fishman RF, Meyers SN, Schaechter AG, Goodreau LM, Davidson CJ. Benefit of intracoronary ultrasound after angiographically optimal Palmaz-Schatz stent deployment. Circulation. 1996;94(suppl I):I-262. Abstract.
    • (1996) Circulation , vol.94 , Issue.1 SUPPL.
    • Vardi, G.M.1    Fishman, R.F.2    Meyers, S.N.3    Schaechter, A.G.4    Goodreau, L.M.5    Davidson, C.J.6
  • 11
    • 0026592026 scopus 로고
    • The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting
    • Kuntz RE, Safian RD, Carrozza JP, Fishman RF, Mansour M, Baim DS. The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting. Circulation. 1992;86:1827-1835.
    • (1992) Circulation , vol.86 , pp. 1827-1835
    • Kuntz, R.E.1    Safian, R.D.2    Carrozza, J.P.3    Fishman, R.F.4    Mansour, M.5    Baim, D.S.6
  • 12
    • 0027475430 scopus 로고
    • Generalized model of restenosis after conventional balloon angioplasty, stenting and directional atherectomy
    • Kuntz RE, Gibson CM, Nobuyoshi M, Baim DS. Generalized model of restenosis after conventional balloon angioplasty, stenting and directional atherectomy. J Am Coll Cardiol. 1993;21:15-25.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 15-25
    • Kuntz, R.E.1    Gibson, C.M.2    Nobuyoshi, M.3    Baim, D.S.4
  • 13
    • 0028822162 scopus 로고
    • Matching to guide the design and predict the outcome of randomized atherectomy trials
    • Umans VA, Keane D, Quaedvlieg P, Serruys PW. Matching to guide the design and predict the outcome of randomized atherectomy trials. Am Heart J. 1995;130:1135-1143.
    • (1995) Am Heart J , vol.130 , pp. 1135-1143
    • Umans, V.A.1    Keane, D.2    Quaedvlieg, P.3    Serruys, P.W.4
  • 18
    • 0024844383 scopus 로고
    • Impact of compensatory enlargement of atherosclerotic coronary arteries on angiographic assessment of coronary disease
    • Stiel GM, Stiel LG, Schofer J, Donath K, Mathey DG. Impact of compensatory enlargement of atherosclerotic coronary arteries on angiographic assessment of coronary disease. Circulation. 1989;80: 1603-1609.
    • (1989) Circulation , vol.80 , pp. 1603-1609
    • Stiel, G.M.1    Stiel, L.G.2    Schofer, J.3    Donath, K.4    Mathey, D.G.5
  • 19
    • 0021351699 scopus 로고
    • A new digital electronic caliper for measurement of coronary arterial stenosis: A comparison with visual and computer assisted measurements
    • Scoblianko DP, Brown G, Mitten S. A new digital electronic caliper for measurement of coronary arterial stenosis: a comparison with visual and computer assisted measurements. Am J Cardiol. 1984; 53:689-693.
    • (1984) Am J Cardiol , vol.53 , pp. 689-693
    • Scoblianko, D.P.1    Brown, G.2    Mitten, S.3
  • 20
    • 0025252534 scopus 로고
    • Video densitometry versus digital calipers for quantitative coronary angiography
    • Theron HT, Lambert CR, Pepine CJ. Video densitometry versus digital calipers for quantitative coronary angiography. Am J Cardiol. 1990;66:1886-1890.
    • (1990) Am J Cardiol , vol.66 , pp. 1886-1890
    • Theron, H.T.1    Lambert, C.R.2    Pepine, C.J.3
  • 21
    • 0023740319 scopus 로고
    • Guidelines for percutaneous transluminal coronary angioplasty: A report of the American College of Cardiology/American Heart Association Task Force on assessment of diagnostic and therapeutic cardiovascular procedures
    • Ryan TJ, Faxon DP, Gunnar RM, Kennedy JW, King SB III, Loop FD, Peterson KL, Reeves TJ, Williams DO, Winters WL Jr. Guidelines for percutaneous transluminal coronary angioplasty: a report of the American College of Cardiology/American Heart Association Task Force on assessment of diagnostic and therapeutic cardiovascular procedures. Circulation. 1988;78:486-502.
    • (1988) Circulation , vol.78 , pp. 486-502
    • Ryan, T.J.1    Faxon, D.P.2    Gunnar, R.M.3    Kennedy, J.W.4    King S.B. III5    Loop, F.D.6    Peterson, K.L.7    Reeves, T.J.8    Williams, D.O.9    Winters W.L., Jr.10
  • 23
    • 2442469172 scopus 로고    scopus 로고
    • The impact of preintervention plaque area determined by intravascular ultrasound on luminal renarrowing following coronary stenting
    • Abstract
    • Moussa I, Di Mario C, Moses J, Di Francesco L, Reimers B, Tobis J, Colombo A. The impact of preintervention plaque area determined by intravascular ultrasound on luminal renarrowing following coronary stenting. Circulation. 1996;94(suppl I):I-261. Abstract.
    • (1996) Circulation , vol.94 , Issue.1 SUPPL.
    • Moussa, I.1    Di Mario, C.2    Moses, J.3    Di Francesco, L.4    Reimers, B.5    Tobis, J.6    Colombo, A.7
  • 24
    • 0025055249 scopus 로고
    • Factors influencing restenosis after coronary angioplasty
    • Popma JJ, Topol EJ. Factors influencing restenosis after coronary angioplasty. Am J Med. 1990;88:1N,16N-24N.
    • (1990) Am J Med. , vol.88
    • Popma, J.J.1    Topol, E.J.2
  • 25
    • 85036682071 scopus 로고    scopus 로고
    • Incidence and implications of coronary dissection after PTCA using oversized balloons with intravascular ultrasound guidance: The CLOUT trial
    • Abstract
    • Stone GW, Linnemeier TJ, Frey A, Mudra H, St Goar FG, Sheehan H, Hodgson J. Incidence and implications of coronary dissection after PTCA using oversized balloons with intravascular ultrasound guidance: the CLOUT trial. Circulation. 1996;94(suppl I):I-261. Abstract.
    • (1996) Circulation , vol.94 , Issue.1 SUPPL.
    • Stone, G.W.1    Linnemeier, T.J.2    Frey, A.3    Mudra, H.4    St Goar, F.G.5    Sheehan, H.6    Hodgson, J.7
  • 26
    • 0342292868 scopus 로고    scopus 로고
    • Interaction of balloon size and pressure for optimal stent deployment using intracoronary ultrasound guidance
    • Abstract
    • Vardi GM, Fishman RF, Ailwadi GA, Parker MA, Meyers SN, Davidson CJ. Interaction of balloon size and pressure for optimal stent deployment using intracoronary ultrasound guidance. Circulation. 1996;94(suppl I):I-262. Abstract.
    • (1996) Circulation , vol.94 , Issue.1 SUPPL.
    • Vardi, G.M.1    Fishman, R.F.2    Ailwadi, G.A.3    Parker, M.A.4    Meyers, S.N.5    Davidson, C.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.