메뉴 건너뛰기




Volumn 40, Issue 6, 2009, Pages 575-581

Olecranon fractures

Author keywords

Elbow anatomy; Fracture classification; Intramedullary fixation; Olecranon fracture; Plate fixation; Tension band fixation

Indexed keywords

ANATOMY; BONE PLATE; COMMINUTED FRACTURE; DISEASE CLASSIFICATION; ELBOW RADIOGRAPHY; FRACTURE NONUNION; FUNCTIONAL ASSESSMENT; HUMAN; INTRAMEDULLARY NAILING; KIRSCHNER WIRE; MOBILIZATION; OLECRANON FRACTURE; OSTEOSYNTHESIS; OUTCOME ASSESSMENT; PATIENT ASSESSMENT; PATIENT COMPLIANCE; PLATE FIXATION; PRIORITY JOURNAL; REVIEW; WOUND HEALING;

EID: 67349287797     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.injury.2008.12.013     Document Type: Review
Times cited : (124)

References (45)
  • 1
    • 0028912055 scopus 로고
    • The mechanism of elbow fractures: an investigation using impact tests in vitro
    • Amis A.A., and Miller J.H. The mechanism of elbow fractures: an investigation using impact tests in vitro. Injury 26 (1995) 163-168
    • (1995) Injury , vol.26 , pp. 163-168
    • Amis, A.A.1    Miller, J.H.2
  • 2
    • 0022542187 scopus 로고
    • The effect of partial removal of proximal ulna on elbow constraint
    • An K.N., Morrey B.F., and Chao E.Y.S. The effect of partial removal of proximal ulna on elbow constraint. Clin Orthop 209 (1986) 270-279
    • (1986) Clin Orthop , vol.209 , pp. 270-279
    • An, K.N.1    Morrey, B.F.2    Chao, E.Y.S.3
  • 4
    • 0035217656 scopus 로고    scopus 로고
    • Outcome of plate fixation of olecranon fractures
    • Bailey C.S., MacDermid J., Patterson S.D., et al. Outcome of plate fixation of olecranon fractures. J Orthop Trauma 15 8 (2001) 542-548
    • (2001) J Orthop Trauma , vol.15 , Issue.8 , pp. 542-548
    • Bailey, C.S.1    MacDermid, J.2    Patterson, S.D.3
  • 6
    • 24644485953 scopus 로고    scopus 로고
    • Impaired forearm rotation after tension-band-wiring fixation of olecranon fractures
    • Candal-Couto J.J., Williams J.R., and Sanderson P.L. Impaired forearm rotation after tension-band-wiring fixation of olecranon fractures. J Orthop Trauma 19 (2005) 480-482
    • (2005) J Orthop Trauma , vol.19 , pp. 480-482
    • Candal-Couto, J.J.1    Williams, J.R.2    Sanderson, P.L.3
  • 7
    • 34548500848 scopus 로고    scopus 로고
    • Olecranon fractures repaired with FiberWire or metal wire tension banding: a biomechanical comparison
    • Carofino B.C., Santangelo S.A., Kabadi M., MMazzocca A.D., and Browner B.D. Olecranon fractures repaired with FiberWire or metal wire tension banding: a biomechanical comparison. Arthroscopy 23 9 (2007) 964-970
    • (2007) Arthroscopy , vol.23 , Issue.9 , pp. 964-970
    • Carofino, B.C.1    Santangelo, S.A.2    Kabadi, M.3    MMazzocca, A.D.4    Browner, B.D.5
  • 8
    • 0015686712 scopus 로고
    • Fractures of the olecranon in adults: classification and management
    • Colton C.L. Fractures of the olecranon in adults: classification and management. Injury 5 2 (1973) 121-129
    • (1973) Injury , vol.5 , Issue.2 , pp. 121-129
    • Colton, C.L.1
  • 9
    • 0037242994 scopus 로고    scopus 로고
    • Partial olecranon excision: the relationship between triceps insertion site and extension strength of the elbow
    • DiDonna M., Fernadez J., Lim T., Hastings H., and Cohen M. Partial olecranon excision: the relationship between triceps insertion site and extension strength of the elbow. J Hand Surg 28A (2003) 117-122
    • (2003) J Hand Surg , vol.28 A , pp. 117-122
    • DiDonna, M.1    Fernadez, J.2    Lim, T.3    Hastings, H.4    Cohen, M.5
  • 10
    • 0021958564 scopus 로고
    • Methods of fixation of olecranon fractures: an experimental mechanical study
    • Fyfe J.S., Mossad M.M., and Holdsworth B.J. Methods of fixation of olecranon fractures: an experimental mechanical study. J Bone Joint Surg Br 67 (1985) 367-372
    • (1985) J Bone Joint Surg Br , vol.67 , pp. 367-372
    • Fyfe, J.S.1    Mossad, M.M.2    Holdsworth, B.J.3
  • 11
    • 0019471009 scopus 로고
    • Operative treatment of olecranon fractures. Excision or open reduction with internal fixation
    • Gartsman G.M., Sculco T.P., and Otis J.C. Operative treatment of olecranon fractures. Excision or open reduction with internal fixation. J Bone Joint Surg Am 63 5 (1981) 718-721
    • (1981) J Bone Joint Surg Am , vol.63 , Issue.5 , pp. 718-721
    • Gartsman, G.M.1    Sculco, T.P.2    Otis, J.C.3
  • 12
    • 33748299486 scopus 로고    scopus 로고
    • Intramedullary locking compression nail for the treatment of an olecranon fracture
    • Gehr J., and Friedl W. Intramedullary locking compression nail for the treatment of an olecranon fracture. Oper Orthop Traumatol 18 3 (2006) 199-213
    • (2006) Oper Orthop Traumatol , vol.18 , Issue.3 , pp. 199-213
    • Gehr, J.1    Friedl, W.2
  • 14
    • 0034222840 scopus 로고    scopus 로고
    • Olecranon fractures: treatment options
    • Hak D.J., and Golladay G.J. Olecranon fractures: treatment options. J Am Acad Orthop Surg 8 (2000) 266-275
    • (2000) J Am Acad Orthop Surg , vol.8 , pp. 266-275
    • Hak, D.J.1    Golladay, G.J.2
  • 15
    • 0037320083 scopus 로고    scopus 로고
    • Comparison of the mechanical properties of different tension band materials and suture techniques
    • Harrell R.M., Tong J., Weinhold P.S., and Dahners L.E. Comparison of the mechanical properties of different tension band materials and suture techniques. J Orthop Trauma 17 2 (2003) 119-122
    • (2003) J Orthop Trauma , vol.17 , Issue.2 , pp. 119-122
    • Harrell, R.M.1    Tong, J.2    Weinhold, P.S.3    Dahners, L.E.4
  • 16
    • 0023074140 scopus 로고
    • The complications of surgical treatment of displaced fractures of the olecranon
    • Helm R.H., Hornby R., and Miller S.W.M. The complications of surgical treatment of displaced fractures of the olecranon. Injury 18 (1987) 48-50
    • (1987) Injury , vol.18 , pp. 48-50
    • Helm, R.H.1    Hornby, R.2    Miller, S.W.M.3
  • 17
    • 0002479558 scopus 로고    scopus 로고
    • Fractures of the olecranon
    • Rockwood Jr. C.A., Green D.P., Bucholz R.W., and Heckman J.D. (Eds), JB Lippencott, Philadelphia
    • Hotchkiss R.N. Fractures of the olecranon. In: Rockwood Jr. C.A., Green D.P., Bucholz R.W., and Heckman J.D. (Eds). Rockwood and greens fractures in adults. 4th ed. (1996), JB Lippencott, Philadelphia
    • (1996) Rockwood and greens fractures in adults. 4th ed.
    • Hotchkiss, R.N.1
  • 18
    • 0026467239 scopus 로고
    • Olecranon fractures. A clinical and radiographic comparison of tension band wiring and plate fixation
    • Hume M.C., and Wiss D.A. Olecranon fractures. A clinical and radiographic comparison of tension band wiring and plate fixation. Clin Orthop Relat Res 285 (1992) 229-235
    • (1992) Clin Orthop Relat Res , vol.285 , pp. 229-235
    • Hume, M.C.1    Wiss, D.A.2
  • 19
    • 67349186462 scopus 로고    scopus 로고
    • the treatment of olecranon fractures by excision of fragments and repair of the extensor mechanism: historical review and report of 12 fractures
    • Inhofe P.D., and Howard T.C. the treatment of olecranon fractures by excision of fragments and repair of the extensor mechanism: historical review and report of 12 fractures. Orthopedics 21 (1998) 265-268
    • (1998) Orthopedics , vol.21 , pp. 265-268
    • Inhofe, P.D.1    Howard, T.C.2
  • 20
    • 0022631661 scopus 로고
    • Olecranon fractures treated with AO screw and tension bands
    • Johnson R.P., Roetker A., and Schwab J.P. Olecranon fractures treated with AO screw and tension bands. Orthopedics 9 (1986) 66-68
    • (1986) Orthopedics , vol.9 , pp. 66-68
    • Johnson, R.P.1    Roetker, A.2    Schwab, J.P.3
  • 21
    • 0042849085 scopus 로고    scopus 로고
    • Comparison of tension-band and figure-of-eight wiring techniques for treatment of olecranon fractures
    • Karlsson M.K., Hasserius R., Besjakov J., Karlsson C., and Josefsson P.O. Comparison of tension-band and figure-of-eight wiring techniques for treatment of olecranon fractures. J Shoulder Elbow Surg 11 4 (2002) 377-382
    • (2002) J Shoulder Elbow Surg , vol.11 , Issue.4 , pp. 377-382
    • Karlsson, M.K.1    Hasserius, R.2    Besjakov, J.3    Karlsson, C.4    Josefsson, P.O.5
  • 23
    • 27744469408 scopus 로고    scopus 로고
    • New tension band material for fixation of transverse olecranon fractures: a biomechanical study
    • Lalonde J.A., Rabalais R.D., Mansour A., et al. New tension band material for fixation of transverse olecranon fractures: a biomechanical study. Orthopedics 28 10 (2005) 1191-1194
    • (2005) Orthopedics , vol.28 , Issue.10 , pp. 1191-1194
    • Lalonde, J.A.1    Rabalais, R.D.2    Mansour, A.3
  • 24
    • 3242678201 scopus 로고    scopus 로고
    • Fractures of the olecranon
    • Lavigne G., and Baratz M. Fractures of the olecranon. J Am Soc Surg Hand 4 2 (2004) 94-102
    • (2004) J Am Soc Surg Hand , vol.4 , Issue.2 , pp. 94-102
    • Lavigne, G.1    Baratz, M.2
  • 25
    • 84872640967 scopus 로고
    • Fracture of the olecranon process of the ulna: treatment by excision of fragment and repair of triceps tendon
    • McKeever F.M., and Buck R.M. Fracture of the olecranon process of the ulna: treatment by excision of fragment and repair of triceps tendon. JAMA 135 (1947) 1-5
    • (1947) JAMA , vol.135 , pp. 1-5
    • McKeever, F.M.1    Buck, R.M.2
  • 26
    • 0002375204 scopus 로고
    • Fractures of the proximal ulna and olecranon
    • WB Saunders, Philadelphia pp. 405-428
    • Morrey B.F., and Adams R.A. Fractures of the proximal ulna and olecranon. The elbow and its disorders (1993), WB Saunders, Philadelphia pp. 405-428
    • (1993) The elbow and its disorders
    • Morrey, B.F.1    Adams, R.A.2
  • 27
    • 1642406116 scopus 로고    scopus 로고
    • Biomechanical evaluation of intramedullary nail versus tension band fixation for transverse olecranon fractures
    • Molloy S., Jasper L.E., Elliott D.S., Brumback R.J., and Belkoff S.M. Biomechanical evaluation of intramedullary nail versus tension band fixation for transverse olecranon fractures. J Orthop Trauma 18 3 (2004) 170-174
    • (2004) J Orthop Trauma , vol.18 , Issue.3 , pp. 170-174
    • Molloy, S.1    Jasper, L.E.2    Elliott, D.S.3    Brumback, R.J.4    Belkoff, S.M.5
  • 28
    • 0028900724 scopus 로고
    • Current concepts in the treatment of fractures of the radial head, the olecranon, and the coronoid
    • Morrey B.F. Current concepts in the treatment of fractures of the radial head, the olecranon, and the coronoid. J Bone Joint Surg Am 77 (1995) 316-327
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 316-327
    • Morrey, B.F.1
  • 30
    • 0034237449 scopus 로고    scopus 로고
    • K-wire position in tension band wiring of the olecranon-a comparison of two techniques
    • Mullett J.H., Shannon F., Noel J., et al. K-wire position in tension band wiring of the olecranon-a comparison of two techniques. Injury 31 6 (2000) 427-431
    • (2000) Injury , vol.31 , Issue.6 , pp. 427-431
    • Mullett, J.H.1    Shannon, F.2    Noel, J.3
  • 31
    • 34249276660 scopus 로고    scopus 로고
    • Dynamic biomechanical analysis of different olecranon fracture fixation devices-tension band wiring versus two intra-medullary nail systems: an in vitro cadaveric study
    • Nowak T.E., Mueller L.P., Buckhart K.J., Sternstein W., Reuter M., and Rommens P.M. Dynamic biomechanical analysis of different olecranon fracture fixation devices-tension band wiring versus two intra-medullary nail systems: an in vitro cadaveric study. Clin Biomech (Bristol, Avon) 22 6 (2007) 658-664
    • (2007) Clin Biomech (Bristol, Avon) , vol.22 , Issue.6 , pp. 658-664
    • Nowak, T.E.1    Mueller, L.P.2    Buckhart, K.J.3    Sternstein, W.4    Reuter, M.5    Rommens, P.M.6
  • 32
  • 33
    • 26444448381 scopus 로고    scopus 로고
    • Anterior interosseous nerve injury following tension band wiring of the olecranon
    • Parker J.R., Conroy J., and Campbell D.A. Anterior interosseous nerve injury following tension band wiring of the olecranon. Injury 36 (2005) 1252-1253
    • (2005) Injury , vol.36 , pp. 1252-1253
    • Parker, J.R.1    Conroy, J.2    Campbell, D.A.3
  • 34
    • 41649115629 scopus 로고    scopus 로고
    • Safe zone for anterior cortical perforation of the ulna during tension-band wire fixation: a magnetic resonance imaging analysis
    • Prayson M.J., Iossi M.F., Buchalter D., Vogt M., and Towers J. Safe zone for anterior cortical perforation of the ulna during tension-band wire fixation: a magnetic resonance imaging analysis. J Shoulder Elbow Surg 17 1 (2008) 121-125
    • (2008) J Shoulder Elbow Surg , vol.17 , Issue.1 , pp. 121-125
    • Prayson, M.J.1    Iossi, M.F.2    Buchalter, D.3    Vogt, M.4    Towers, J.5
  • 35
    • 0031267131 scopus 로고    scopus 로고
    • Biomechanical comparison of fixation methods in transverse olecranon fractures: a cadaveric study
    • Prayson M.J., Williams J.L., Marshall M.P., Scilaris T.A., and Lingenfelter E.J. Biomechanical comparison of fixation methods in transverse olecranon fractures: a cadaveric study. J Orthop Trauma 11 8 (1997) 565-772
    • (1997) J Orthop Trauma , vol.11 , Issue.8 , pp. 565-772
    • Prayson, M.J.1    Williams, J.L.2    Marshall, M.P.3    Scilaris, T.A.4    Lingenfelter, E.J.5
  • 36
    • 5444224885 scopus 로고    scopus 로고
    • Olecranon fractures in adults: factors influencing outcome
    • Rommens P.M., Kuchle R., Schneider R.U., and Reuter M.M. Olecranon fractures in adults: factors influencing outcome. Injury 35 (2004) 1149-1157
    • (2004) Injury , vol.35 , pp. 1149-1157
    • Rommens, P.M.1    Kuchle, R.2    Schneider, R.U.3    Reuter, M.M.4
  • 37
    • 0030198892 scopus 로고    scopus 로고
    • Contoured LC-DC plating of the proximal ulna
    • Simpson N.S., Goodman L.A., and Jupiter J.B. Contoured LC-DC plating of the proximal ulna. Injury 27 6 (1996) 411-417
    • (1996) Injury , vol.27 , Issue.6 , pp. 411-417
    • Simpson, N.S.1    Goodman, L.A.2    Jupiter, J.B.3
  • 39
    • 0032929283 scopus 로고    scopus 로고
    • Conservative treatment of displaced fractures of the olecranon in the elderly
    • Veras Del Monte L., Sirera Vercher M., Busquets Net R., et al. Conservative treatment of displaced fractures of the olecranon in the elderly. Injury 30 (1999) 105-110
    • (1999) Injury , vol.30 , pp. 105-110
    • Veras Del Monte, L.1    Sirera Vercher, M.2    Busquets Net, R.3
  • 40
    • 0017202464 scopus 로고
    • Screw fixation of the olecranon after fracture or osteotomy
    • Wadsworth T.G. Screw fixation of the olecranon after fracture or osteotomy. Clin Othop 119 (1976) 197-201
    • (1976) Clin Othop , vol.119 , pp. 197-201
    • Wadsworth, T.G.1
  • 41
    • 0042527171 scopus 로고    scopus 로고
    • The proximal ulna: an anatomic study with relevance to olecranon osteotomy and fracture fixation
    • Wang A., Mara M., and Hutchinson D.T. The proximal ulna: an anatomic study with relevance to olecranon osteotomy and fracture fixation. J Shoulder Elbow Surg 12 3 (2003) 293-296
    • (2003) J Shoulder Elbow Surg , vol.12 , Issue.3 , pp. 293-296
    • Wang, A.1    Mara, M.2    Hutchinson, D.T.3
  • 42
    • 0002936230 scopus 로고
    • Osteosynthese bei Olekranonfraktur
    • Weber B.G., and Vasey H. Osteosynthese bei Olekranonfraktur. Z Unfallmmed Berufskr 56 (1963) 90-96
    • (1963) Z Unfallmmed Berufskr , vol.56 , pp. 90-96
    • Weber, B.G.1    Vasey, H.2
  • 43
    • 0017137085 scopus 로고
    • The use of the Zuelzer hook plate in fixation of olecranon fractures
    • Weseley M.S., Barenfield P.A., and Eisenstein A.L. The use of the Zuelzer hook plate in fixation of olecranon fractures. J Bone Joint Surg Am 58 (1976) 859-863
    • (1976) J Bone Joint Surg Am , vol.58 , pp. 859-863
    • Weseley, M.S.1    Barenfield, P.A.2    Eisenstein, A.L.3
  • 44
    • 0023472436 scopus 로고
    • Surgical treatment of displaced olecranon fractures by tension band wiring technique
    • Wolfgang G., Burke F., Bush D., et al. Surgical treatment of displaced olecranon fractures by tension band wiring technique. Clin Orthop Relat Res 224 (1987) 192-204
    • (1987) Clin Orthop Relat Res , vol.224 , pp. 192-204
    • Wolfgang, G.1    Burke, F.2    Bush, D.3
  • 45
    • 0033945691 scopus 로고    scopus 로고
    • Biomechanical comparison for different configurations of tension band wiring techniques in treating an olecranon fracture
    • Wu C.C., Tai C.L., and Shih C.H. Biomechanical comparison for different configurations of tension band wiring techniques in treating an olecranon fracture. J Trauma 48 6 (2000) 1063-1067
    • (2000) J Trauma , vol.48 , Issue.6 , pp. 1063-1067
    • Wu, C.C.1    Tai, C.L.2    Shih, C.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.