메뉴 건너뛰기




Volumn 35, Issue 11, 2004, Pages 1149-1157

Olecranon fractures in adults: Factors influencing outcome

Author keywords

Arthrosis; Classification systems; Elbow function; Elbow instability; Olecranon fracture; Prognostic factors; Proximal radius lesion; Tension band wiring

Indexed keywords

ADULT; AGE; AGED; COMORBIDITY; CONTROLLED STUDY; CORRELATION ANALYSIS; DAILY LIFE ACTIVITY; DEATH; DEVICE REMOVAL; DISEASE CLASSIFICATION; DYSESTHESIA; ELBOW; EVALUATION; EXPERIENCE; FEMALE; FOLLOW UP; FRACTURE HEALING; HUMAN; IMPLANT; JOINT FUNCTION; JOINT INSTABILITY; JOINT MOBILITY; MAJOR CLINICAL STUDY; MALE; MEDICAL RECORD; MORPHOLOGY; MUSCLE STRENGTH; NEUROLYSIS; OLECRANON FRACTURE; OSTEOARTHRITIS; OSTEOSYNTHESIS; POSTOPERATIVE PAIN; PRIORITY JOURNAL; PROGNOSIS; PROSTHESIS LOOSENING; PSEUDARTHROSIS; RETROSPECTIVE STUDY; REVIEW; TREATMENT OUTCOME; X RAY;

EID: 5444224885     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.injury.2003.12.002     Document Type: Article
Times cited : (198)

References (15)
  • 1
    • 0019431055 scopus 로고
    • Olecranon fractures: A review of 100 cases
    • Horne J.G., Tanzer T.L. Olecranon fractures: a review of 100 cases. J. Trauma. 21:1981;469-472
    • (1981) J. Trauma , vol.21 , pp. 469-472
    • Horne, J.G.1    Tanzer, T.L.2
  • 2
    • 0022497793 scopus 로고
    • Drawbacks of traction-absorbing wiring (TAW) in displaced fractures of the olecranon
    • Jensen C.M., Olsen B.B. Drawbacks of traction-absorbing wiring (TAW) in displaced fractures of the olecranon. Injury. 17:1986;174-175
    • (1986) Injury , vol.17 , pp. 174-175
    • Jensen, C.M.1    Olsen, B.B.2
  • 3
    • 0031464365 scopus 로고    scopus 로고
    • The Hastings experience of the Attenborough springs and Rush nail for fixation of olecranon fractures
    • Joshi R.P. The Hastings experience of the Attenborough springs and Rush nail for fixation of olecranon fractures. Injury. 28:1997;455-458
    • (1997) Injury , vol.28 , pp. 455-458
    • Joshi, R.P.1
  • 4
    • 0025741050 scopus 로고
    • Tension-band wiring of olecranon fractures with non-sliding pins. Report of 20 cases
    • Larsen E., Jensen C.M. Tension-band wiring of olecranon fractures with non-sliding pins. Report of 20 cases. Acta Orthop. Scand. 62:1991;360-362
    • (1991) Acta Orthop. Scand. , vol.62 , pp. 360-362
    • Larsen, E.1    Jensen, C.M.2
  • 5
    • 0022308950 scopus 로고
    • Complications of tension-band wiring of olecranon fractures
    • Macko M.D., Szabo R.M. Complications of tension-band wiring of olecranon fractures. J. Bone Jt. Surg. 67-A:1985;1397-1401
    • (1985) J. Bone Jt. Surg. , vol.67 , pp. 1397-1401
    • MacKo, M.D.1    Szabo, R.M.2
  • 6
    • 2442520677 scopus 로고    scopus 로고
    • Traumatologie des Schultergürtels und obere Extremität
    • Schumpelick V, Bleese NM, Mommsen U, editors. Stuttgart: Ferdinand Enke Verlag;
    • Mommsen U, Holzrichter D. Traumatologie des Schultergürtels und obere Extremität. In: Schumpelick V, Bleese NM, Mommsen U, editors. Chirurgie, 4th ed. Stuttgart: Ferdinand Enke Verlag; 1999. p. 1203-28.
    • (1999) Chirurgie, 4th Ed. , pp. 1203-1228
    • Mommsen, U.1    Holzrichter, D.2
  • 7
    • 0028900724 scopus 로고
    • Current concepts in the treatment of fractures of the radial head, the olecranon and the coronoid
    • Morrey B.F. Current concepts in the treatment of fractures of the radial head, the olecranon and the coronoid. J. Bone Jt. Surg. 77A:1995;316-327
    • (1995) J. Bone Jt. Surg. , vol.77 , pp. 316-327
    • Morrey, B.F.1
  • 8
    • 0033864806 scopus 로고    scopus 로고
    • Comminuted fracture-dislocations of the elbow treated with an AO wrist fusion plate
    • Nowinski R.J., Nork S.E., Segina D.N., Benirschke S.K. Comminuted fracture-dislocations of the elbow treated with an AO wrist fusion plate. Clin. Orthop. 378:2000;238-244
    • (2000) Clin. Orthop. , vol.378 , pp. 238-244
    • Nowinski, R.J.1    Nork, S.E.2    Segina, D.N.3    Benirschke, S.K.4
  • 9
    • 0033831194 scopus 로고    scopus 로고
    • Complications and reoperation rate after tension-band wiring of olecranon fractures
    • Romero J.M., Miran A., Jensen C.H. Complications and reoperation rate after tension-band wiring of olecranon fractures. J. Orthop. Sci. 5:2000;318-320
    • (2000) J. Orthop. Sci. , vol.5 , pp. 318-320
    • Romero, J.M.1    Miran, A.2    Jensen, C.H.3
  • 10
    • 0026572229 scopus 로고
    • Tension band wiring of olecranon fractures: A modification of the AO technique
    • Rowland S.A., Burkhardt S.S. Tension band wiring of olecranon fractures: a modification of the AO technique. Clin. Orthop. 277:1992;238-242
    • (1992) Clin. Orthop. , vol.277 , pp. 238-242
    • Rowland, S.A.1    Burkhardt, S.S.2
  • 11
    • 0342777698 scopus 로고    scopus 로고
    • Fractures of the olecranon
    • Schatzker J, Tile M, editors. Berlin: Springer Verlag;
    • Schatzker J. Fractures of the olecranon. In: Schatzker J, Tile M, editors. The rationale of operative fracture care, 2nd ed. Berlin: Springer Verlag; 1996. p. 113-9.
    • (1996) The Rationale of Operative Fracture Care, 2nd Ed. , pp. 113-119
    • Schatzker, J.1
  • 12
    • 2442530161 scopus 로고    scopus 로고
    • Olecranon fractures: Open reduction internal fixation
    • Wiss D, editor. Philadelphia: Lippincott Raven;
    • Schmeling GJ. Olecranon fractures: open reduction internal fixation. In: Wiss D, editor. Master techniques in orthopedic surgery-fractures. Philadelphia: Lippincott Raven; 1998. p. 113-28.
    • (1998) Master Techniques in Orthopedic Surgery-fractures , pp. 113-128
    • Schmeling, G.J.1
  • 13
    • 0017202464 scopus 로고
    • Screw fixation of the olecranon after fracture or osteotomy
    • Wadsworth T.G. Screw fixation of the olecranon after fracture or osteotomy. Clin. Orthop. 119:1976;197-201
    • (1976) Clin. Orthop. , vol.119 , pp. 197-201
    • Wadsworth, T.G.1
  • 15
    • 0033945691 scopus 로고    scopus 로고
    • Biomechanical comparison for different configurations of tension band wiring techniques in treating an olecranon fracture
    • Wu C.C., Tai C.L., Shih C.H. Biomechanical comparison for different configurations of tension band wiring techniques in treating an olecranon fracture. J. Trauma. 48:2000;1063-1067
    • (2000) J. Trauma , vol.48 , pp. 1063-1067
    • Wu, C.C.1    Tai, C.L.2    Shih, C.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.