메뉴 건너뛰기




Volumn 24, Issue 4, 2009, Pages 594-606

Comparison of the Model-Based and Marker-Based Roentgen Stereophotogrammetry Methods in a Typical Clinical Setting

Author keywords

clinical accuracy; knee arthroplasty; pose estimation; prosthesis migration; Roentgen stereophotogrammetry

Indexed keywords

TANTALUM;

EID: 67349223235     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2008.02.004     Document Type: Article
Times cited : (40)

References (32)
  • 1
    • 0024317955 scopus 로고
    • Roentgen stereophotogrammetry. Review of orthopedic applications.
    • Karrholm J. Roentgen stereophotogrammetry. Review of orthopedic applications. Acta Orthop Scand 60 (1989) 491
    • (1989) Acta Orthop Scand , vol.60 , pp. 491
    • Karrholm, J.1
  • 2
    • 0024388994 scopus 로고
    • Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system
    • Selvik G. Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl 232 (1989) 1
    • (1989) Acta Orthop Scand Suppl , vol.232 , pp. 1
    • Selvik, G.1
  • 3
    • 0027938815 scopus 로고
    • Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis
    • Karrholm J., Malchau H., Snorrason F., et al. Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. J Bone Joint Surg Am 76 (1994) 1692
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 1692
    • Karrholm, J.1    Malchau, H.2    Snorrason, F.3
  • 4
    • 0029056371 scopus 로고
    • Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
    • Ryd L., Albrektsson B.E., Carlsson L., et al. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Joint Surg Br 77 (1995) 377
    • (1995) J Bone Joint Surg Br , vol.77 , pp. 377
    • Ryd, L.1    Albrektsson, B.E.2    Carlsson, L.3
  • 5
    • 0032805261 scopus 로고    scopus 로고
    • The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis
    • Krismer M., Biedermann R., Stockl B., et al. The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis. J Bone Joint Surg Br 81 (1999) 273
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 273
    • Krismer, M.1    Biedermann, R.2    Stockl, B.3
  • 6
    • 0028282143 scopus 로고
    • Early migration and late aseptic failure of proximal femoral prostheses
    • Freeman M.A., and Plante-Bordeneuve P. Early migration and late aseptic failure of proximal femoral prostheses. J Bone Joint Surg Br 76 (1994) 432
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 432
    • Freeman, M.A.1    Plante-Bordeneuve, P.2
  • 7
    • 0028034860 scopus 로고
    • Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses
    • Karrholm J., Borssen B., Lowenhielm G., et al. Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg Br 76 (1994) 912
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 912
    • Karrholm, J.1    Borssen, B.2    Lowenhielm, G.3
  • 8
    • 33645776769 scopus 로고    scopus 로고
    • Aseptic loosening, not only a question of wear: a review of different theories
    • Sundfeldt M., Carlsson L.V., Johansson C.B., et al. Aseptic loosening, not only a question of wear: a review of different theories. Acta Orthop 77 (2006) 177
    • (2006) Acta Orthop , vol.77 , pp. 177
    • Sundfeldt, M.1    Carlsson, L.V.2    Johansson, C.B.3
  • 9
    • 0034762231 scopus 로고    scopus 로고
    • The Swedish Knee Arthroplasty Register 1975-1997: an update with special emphasis on 41,223 knees operated on in 1988-1997
    • Robertsson O., Knutson K., Lewold S., et al. The Swedish Knee Arthroplasty Register 1975-1997: an update with special emphasis on 41,223 knees operated on in 1988-1997. Acta Orthop Scand 72 (2001) 503
    • (2001) Acta Orthop Scand , vol.72 , pp. 503
    • Robertsson, O.1    Knutson, K.2    Lewold, S.3
  • 10
    • 0033861254 scopus 로고    scopus 로고
    • Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases
    • Herberts P., and Malchau H. Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases. Acta Orthop Scand 71 (2000) 111
    • (2000) Acta Orthop Scand , vol.71 , pp. 111
    • Herberts, P.1    Malchau, H.2
  • 12
    • 0037692766 scopus 로고    scopus 로고
    • A new model-based RSA method validated using CAD models and models from reversed engineering
    • Kaptein B.L., Valstar E.R., Stoel B.C., et al. A new model-based RSA method validated using CAD models and models from reversed engineering. J Biomech 36 (2003) 873
    • (2003) J Biomech , vol.36 , pp. 873
    • Kaptein, B.L.1    Valstar, E.R.2    Stoel, B.C.3
  • 13
  • 14
    • 0034912038 scopus 로고    scopus 로고
    • Model-based roentgen stereophotogrammetry of orthopaedic implants
    • Valstar E.R., de Jong F.W., Vrooman H.A., et al. Model-based roentgen stereophotogrammetry of orthopaedic implants. J Biomech 34 (2001) 715
    • (2001) J Biomech , vol.34 , pp. 715
    • Valstar, E.R.1    de Jong, F.W.2    Vrooman, H.A.3
  • 15
    • 4043169022 scopus 로고    scopus 로고
    • Evaluation of three pose estimation algorithms for model-based roentgen stereophotogrammetric analysis
    • Kaptein B.L., Valstar E.R., Stoel B.C., et al. Evaluation of three pose estimation algorithms for model-based roentgen stereophotogrammetric analysis. Proc Inst Mech Eng [H] 218 (2004) 231
    • (2004) Proc Inst Mech Eng [H] , vol.218 , pp. 231
    • Kaptein, B.L.1    Valstar, E.R.2    Stoel, B.C.3
  • 16
    • 24644467286 scopus 로고    scopus 로고
    • A new type of model-based roentgen stereophotogrammetric analysis for solving the occluded marker problem
    • Kaptein B.L., Valstar E.R., Stoel B.C., et al. A new type of model-based roentgen stereophotogrammetric analysis for solving the occluded marker problem. J Biomech 38 (2005) 2330
    • (2005) J Biomech , vol.38 , pp. 2330
    • Kaptein, B.L.1    Valstar, E.R.2    Stoel, B.C.3
  • 17
    • 33746867139 scopus 로고    scopus 로고
    • Model-based RSA of a femoral hip stem using surface and geometrical shape models
    • Kaptein B.L., Valstar E.R., Spoor C.W., et al. Model-based RSA of a femoral hip stem using surface and geometrical shape models. Clin Orthop Relat Res 448 (2006) 92
    • (2006) Clin Orthop Relat Res , vol.448 , pp. 92
    • Kaptein, B.L.1    Valstar, E.R.2    Spoor, C.W.3
  • 18
    • 0023009684 scopus 로고
    • Mechanical loosening of total hip prostheses. A radiographic and roentgen stereophotogrammetric study
    • Mjoberg B., Selvik G., Hansson L.I., et al. Mechanical loosening of total hip prostheses. A radiographic and roentgen stereophotogrammetric study. J Bone Joint Surg Br 68 (1986) 770
    • (1986) J Bone Joint Surg Br , vol.68 , pp. 770
    • Mjoberg, B.1    Selvik, G.2    Hansson, L.I.3
  • 19
    • 0026806802 scopus 로고
    • Early loosening of femoral components after cemented revision. A roentgen stereophotogrammetric study
    • Franzen H., Mjoberg B., and Onnerfalt R. Early loosening of femoral components after cemented revision. A roentgen stereophotogrammetric study. J Bone Joint Surg Br 74 (1992) 721
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 721
    • Franzen, H.1    Mjoberg, B.2    Onnerfalt, R.3
  • 20
    • 0036677824 scopus 로고    scopus 로고
    • The use of roentgen stereophotogrammetry to study micromotion of orthopaedic implants
    • Valstar E.R., Nelissen R.G., Reiber J.H., et al. The use of roentgen stereophotogrammetry to study micromotion of orthopaedic implants. ISPRS J Photogramm Remote Sens 56 (2002) 376
    • (2002) ISPRS J Photogramm Remote Sens , vol.56 , pp. 376
    • Valstar, E.R.1    Nelissen, R.G.2    Reiber, J.H.3
  • 21
    • 0033875445 scopus 로고    scopus 로고
    • 3-D shape measurement of complex objects by combining photogrammetry and fringe projection
    • Reich C., Ritter R., and Thesing J. 3-D shape measurement of complex objects by combining photogrammetry and fringe projection. Opt Eng 39 (2000) 224
    • (2000) Opt Eng , vol.39 , pp. 224
    • Reich, C.1    Ritter, R.2    Thesing, J.3
  • 22
    • 0242678332 scopus 로고    scopus 로고
    • Optical 3D surface digitizing in forensic medicine: 3D documentation of skin and bone injuries
    • Thali M.J., Braun M., and Dirnhofer R. Optical 3D surface digitizing in forensic medicine: 3D documentation of skin and bone injuries. Forensic Sci Int 137 (2003) 203
    • (2003) Forensic Sci Int , vol.137 , pp. 203
    • Thali, M.J.1    Braun, M.2    Dirnhofer, R.3
  • 25
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307
    • (1986) Lancet , vol.1 , pp. 307
    • Bland, J.M.1    Altman, D.G.2
  • 26
    • 0031984770 scopus 로고    scopus 로고
    • Simultaneous measurements of sagittal knee laxity with an external device and radiostereometric analysis
    • Jorn L.P., Friden T., Ryd L., et al. Simultaneous measurements of sagittal knee laxity with an external device and radiostereometric analysis. J Bone Joint Surg Br 80 (1998) 169
    • (1998) J Bone Joint Surg Br , vol.80 , pp. 169
    • Jorn, L.P.1    Friden, T.2    Ryd, L.3
  • 27
    • 0026651464 scopus 로고
    • Measurement accuracy in acetabular cup migration. A comparison of four radiologic methods versus roentgen stereophotogrammetric analysis
    • Ilchmann T., Franzen H., Mjoberg B., et al. Measurement accuracy in acetabular cup migration. A comparison of four radiologic methods versus roentgen stereophotogrammetric analysis. J Arthroplasty 7 (1992) 121
    • (1992) J Arthroplasty , vol.7 , pp. 121
    • Ilchmann, T.1    Franzen, H.2    Mjoberg, B.3
  • 28
    • 0032797392 scopus 로고    scopus 로고
    • Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacement. Einzel-Bild-Rontgen-Analyse-femoral component analysis
    • Biedermann R., Krismer M., Stockl B., et al. Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacement. Einzel-Bild-Rontgen-Analyse-femoral component analysis. J Bone Joint Surg Br 81 (1999) 266
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 266
    • Biedermann, R.1    Krismer, M.2    Stockl, B.3
  • 29
    • 0027419335 scopus 로고
    • A new radiographic method for detection of tibial component migration in total knee arthroplasty
    • Carlsson L.V., Albrektsson B.E., Freeman M.A., et al. A new radiographic method for detection of tibial component migration in total knee arthroplasty. J Arthroplasty 8 (1993) 117
    • (1993) J Arthroplasty , vol.8 , pp. 117
    • Carlsson, L.V.1    Albrektsson, B.E.2    Freeman, M.A.3
  • 30
    • 33746880700 scopus 로고    scopus 로고
    • Radiostereometric analysis in orthopaedic surgery: editorial comment
    • Valstar E.R., and Gill H.S. Radiostereometric analysis in orthopaedic surgery: editorial comment. Clin Orthop Relat Res 448 (2006) 2
    • (2006) Clin Orthop Relat Res , vol.448 , pp. 2
    • Valstar, E.R.1    Gill, H.S.2
  • 32
    • 24144447269 scopus 로고    scopus 로고
    • Guidelines for standardization of radiostereometry (RSA) of implants
    • Valstar E.R., Gill R., Ryd L., et al. Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 76 (2005) 563
    • (2005) Acta Orthop , vol.76 , pp. 563
    • Valstar, E.R.1    Gill, R.2    Ryd, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.