-
1
-
-
0028282143
-
Early migration and late aseptic failure of proximal femoral prostheses
-
Freeman MAR, Plante-Bordeneuve P. Early migration and late aseptic failure of proximal femoral prostheses. J Bone Joint Surg [Br] 1994;76-B:432-8.
-
(1994)
J Bone Joint Surg [Br]
, vol.76 B
, pp. 432-438
-
-
Freeman, M.A.R.1
Plante-Bordeneuve, P.2
-
2
-
-
0029975392
-
Early migration predicts late aseptic failure of hip sockets
-
Krismer M, Stöckl B, Fischer M, et al. Early migration predicts late aseptic failure of hip sockets. J Bone Joint Surg [Br] 1996;78-B: 422-6.
-
(1996)
J Bone Joint Surg [Br]
, vol.78 B
, pp. 422-426
-
-
Krismer, M.1
Stöckl, B.2
Fischer, M.3
-
3
-
-
0029135432
-
Prediction of clinical outcome of THR from migration measurements on standard radiographs: A study of cemented Charnley and Stanmore femoral stems
-
Walker PS, Mai SF, Cobb AG, Bentley G, Hua J. Prediction of clinical outcome of THR from migration measurements on standard radiographs: a study of cemented Charnley and Stanmore femoral stems. J Bone Joint Surg [Br] 1995;77-B:705-14.
-
(1995)
J Bone Joint Surg [Br]
, vol.77 B
, pp. 705-714
-
-
Walker, P.S.1
Mai, S.F.2
Cobb, A.G.3
Bentley, G.4
Hua, J.5
-
5
-
-
0019962848
-
A ten-year follow-up of one hundred consecutive Müller curved-stem total hipreplacement arthroplasties
-
Sutherland CJ, Wilde AH, Borden LS, Marks KE. A ten-year follow-up of one hundred consecutive Müller curved-stem total hipreplacement arthroplasties. J Bone Joint Surg [Am] 1982;64-A: 970-82.
-
(1982)
J Bone Joint Surg [Am]
, vol.64 A
, pp. 970-982
-
-
Sutherland, C.J.1
Wilde, A.H.2
Borden, L.S.3
Marks, K.E.4
-
6
-
-
0025053461
-
The effect of retention of the femoral neck and of cement upon the stability of a proximal femoral prosthesis
-
Braud P, Freeman MAR. The effect of retention of the femoral neck and of cement upon the stability of a proximal femoral prosthesis. J Arthroplasty 1990;5:s5-10.
-
(1990)
J Arthroplasty
, vol.5
-
-
Braud, P.1
Freeman, M.A.R.2
-
7
-
-
0025797538
-
Measurement of total hip prostheses using image analysis: The MAX-IMA hip technique
-
Hardinge K, Porter ML, Jones PR, Hukins DWL, Taylor CJ. Measurement of total hip prostheses using image analysis: the MAX-IMA hip technique. J Bone Joint Surg [Br] 1991;73-B:724-8.
-
(1991)
J Bone Joint Surg [Br]
, vol.73 B
, pp. 724-728
-
-
Hardinge, K.1
Porter, M.L.2
Jones, P.R.3
Hukins, D.W.L.4
Taylor, C.J.5
-
8
-
-
0004521863
-
Digitale röntgenbildbearbeitung zur messung von schaftwaderungen in der hüftendoprothetik
-
Von Müller R, Matuschek T, Thümler P. Digitale Röntgenbildbearbeitung zur Messung von Schaftwaderungen in der Hüftendoprothetik. Orthop Praxis 1996;32:177-9.
-
(1996)
Orthop Praxis
, vol.32
, pp. 177-179
-
-
Von Müller, R.1
Matuschek, T.2
Thümler, P.3
-
9
-
-
0028892402
-
Accuracy of migration analysis in hip arthroplasty: Digitized and conventional radiography, compared to radiostereometry in 51 patients
-
Malchau H, Kärrholm J, Wang YX, Herberts P. Accuracy of migration analysis in hip arthroplasty: digitized and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop Scand 1995;66:418-24.
-
(1995)
Acta Orthop Scand
, vol.66
, pp. 418-424
-
-
Malchau, H.1
Kärrholm, J.2
Wang, Y.X.3
Herberts, P.4
-
10
-
-
0024388994
-
Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system
-
Selvik G. Roentgen stereophotogrammetry: a method for the study of the kinematics of the skeletal system. Acta Orthop Scand 1989;60 Suppl 232:1-51.
-
(1989)
Acta Orthop Scand
, vol.60
, Issue.SUPPL. 232
, pp. 1-51
-
-
Selvik, G.1
-
11
-
-
0027213551
-
Migration of hydroxyapatite coated femoral stems: A roentgen stereophotogrammetric study
-
Søballe K, Toksvig-Larsen S, Gelineck J, et al. Migration of hydroxyapatite coated femoral stems: a roentgen stereophotogrammetric study. J Bone Joint Surg [Br] 1993;75-B:681-7.
-
(1993)
J Bone Joint Surg [Br]
, vol.75 B
, pp. 681-687
-
-
Søballe, K.1
Toksvig-Larsen, S.2
Gelineck, J.3
-
12
-
-
0023009684
-
Mechanical loosening of total hip prostheses: A radiographic and roentgen stereophotogrammetric study
-
Mjöberg B, Selvik G, Hansson LI, Rosenqvist R, Önnerfält R. Mechanical loosening of total hip prostheses: a radiographic and roentgen stereophotogrammetric study. J Bone Joint Surg [Br] 1986; 68-B:770-4.
-
(1986)
J Bone Joint Surg [Br]
, vol.68 B
, pp. 770-774
-
-
Mjöberg, B.1
Selvik, G.2
Hansson, L.I.3
Rosenqvist, R.4
Önnerfält, R.5
-
13
-
-
0026353010
-
In vivo measurements of relative motion between an uncemented femoral total hip component and the femur by roentgen stereophotogrammetric analysis
-
Nistor L, Blaha JD, Kjellström U, Selvik G. In vivo measurements of relative motion between an uncemented femoral total hip component and the femur by roentgen stereophotogrammetric analysis. Clin Orthop 1991;269:220-7.
-
(1991)
Clin Orthop
, vol.269
, pp. 220-227
-
-
Nistor, L.1
Blaha, J.D.2
Kjellström, U.3
Selvik, G.4
-
14
-
-
0026806802
-
Early loosening of femoral components after cemented revision: A roentgen stereophotogrammetric study
-
Kranzén H, Mjöberg B, Önnerfält R. Early loosening of femoral components after cemented revision: a roentgen stereophotogrammetric study. J Bone Joint Surg [Br] 1992;74-B:721-4.
-
(1992)
J Bone Joint Surg [Br]
, vol.74 B
, pp. 721-724
-
-
Kranzén, H.1
Mjöberg, B.2
Önnerfält, R.3
-
15
-
-
0026751891
-
Subsidence of porous coated non-cemented femoral components in total hip arthroplasty: A roentgen stereophotogrammetric analysis
-
Wykman A, Lundberg A. Subsidence of porous coated non-cemented femoral components in total hip arthroplasty: a roentgen stereophotogrammetric analysis. J Arthroplasty 1992;197-200.
-
(1992)
J Arthroplasty
, pp. 197-200
-
-
Wykman, A.1
Lundberg, A.2
-
16
-
-
0026651464
-
Measurement accuracy in acetabular cup migration: A comparison of four radiologic methods versus roentgen stereophotogrammetric analysis
-
Ilchmann T, Franzen H, Mjöberg B, Wingstrand H. Measurement accuracy in acetabular cup migration: a comparison of four radiologic methods versus roentgen stereophotogrammetric analysis. J Arthroplasty 1992;7:121-7.
-
(1992)
J Arthroplasty
, vol.7
, pp. 121-127
-
-
Ilchmann, T.1
Franzen, H.2
Mjöberg, B.3
Wingstrand, H.4
-
17
-
-
0029380423
-
EBRA: A method to measure migration of acetabular components
-
Krismer M, Bauer R, Tschupik J, Mayrhofer P. EBRA: a method to measure migration of acetabular components. J Biomech 1995;28: 1225-36.
-
(1995)
J Biomech
, vol.28
, pp. 1225-1236
-
-
Krismer, M.1
Bauer, R.2
Tschupik, J.3
Mayrhofer, P.4
-
18
-
-
0024521802
-
Measurement of acetabular erosion: The effect of pelvic rotation on common landmarks
-
Wetherell RG, Amis AA, Heatley FW. Measurement of acetabular erosion: the effect of pelvic rotation on common landmarks. J Bone Joint Surg [Br] 1989;71-B:447-51.
-
(1989)
J Bone Joint Surg [Br]
, vol.71 B
, pp. 447-451
-
-
Wetherell, R.G.1
Amis, A.A.2
Heatley, F.W.3
-
19
-
-
0030948418
-
Single-image roentgen analysis for the measurement of hip endoprosthesis migration
-
Krismer M, Tschupik JP, Bauer R, et al. Single-image roentgen analysis for the measurement of hip endoprosthesis migration. Orthopäde 1997;26:229-36.
-
(1997)
Orthopäde
, vol.26
, pp. 229-236
-
-
Krismer, M.1
Tschupik, J.P.2
Bauer, R.3
-
20
-
-
0030831568
-
Radiographic assessment of cup migration and wear after hip replacement
-
Ilchmann T. Radiographic assessment of cup migration and wear after hip replacement. Acta Orthop Scand 1997;276:1-26.
-
(1997)
Acta Orthop Scand
, vol.276
, pp. 1-26
-
-
Ilchmann, T.1
-
21
-
-
0028034860
-
Does early micromotions of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented hip prostheses
-
Kärrholm J, Borssen B, Löwenhielm G, Snorrason F. Does early micromotions of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented hip prostheses. J Bone Joint Surg [Br] 1994;76-B:912-7.
-
(1994)
J Bone Joint Surg [Br]
, vol.76 B
, pp. 912-917
-
-
Kärrholm, J.1
Borssen, B.2
Löwenhielm, G.3
Snorrason, F.4
-
22
-
-
0027400758
-
Subsidence, tip, and hump micromove-ments of noncoated ribbed femoral prostheses
-
Kärrholm J, Snorrason F. Subsidence, tip, and hump micromove-ments of noncoated ribbed femoral prostheses. Clin Orthop 1993; 287:50-60.
-
(1993)
Clin Orthop
, vol.287
, pp. 50-60
-
-
Kärrholm, J.1
Snorrason, F.2
|