메뉴 건너뛰기




Volumn 11, Issue 3, 2009, Pages 653-661

Antibody immobilization on to polystyrene substrate - On-chip immunoassay for horse IgG based on fluorescence

Author keywords

Covalent bonding; Fluorescence; Horse IgG; Microfluidic card; Polystyrene

Indexed keywords

ANALYTE; ANTIBODY IMMOBILIZATIONS; ANTIBODY-ANTIGEN INTERACTIONS; ATOMIC-FORCE MICROSCOPIES; CONCENTRATION OF; COVALENT BONDING; DETECTION LIMITS; FLUORESCEIN ISOTHIOCYANATE; FLUORESCENCE MICROSCOPES; FUNCTIONALIZED; GOLD-COATED; HORSE IGG; IMMUNOSENSOR CHIPS; LINEAR RESPONSE RANGES; MEDICAL DIAGNOSTICS; MICRO FLUIDIC SYSTEMS; MICRO-ARRAY DETECTIONS; MICROFLUIDIC CARD; MICROFLUIDIC IMMUNOASSAYS; ON CHIPS; PROTEIN-PROTEIN INTERACTIONS; SANDWICH IMMUNOASSAYS; SECONDARY ANTIBODIES; SELF-ASSEMBLED MONOLAYERS; X-RAY PHOTOELECTRON SPECTROSCOPIES;

EID: 67349189525     PISSN: 13872176     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10544-008-9275-3     Document Type: Article
Times cited : (50)

References (36)
  • 1
    • 0035717026 scopus 로고    scopus 로고
    • Point of care testing
    • doi: 10.1016/S1522-8401(01)90036-9
    • M.F. Altieri, M. Camarca, Point of care testing Clin. Pediatr. Emerg. Med 4, 275-279 (2001). doi: 10.1016/S1522-8401(01)90036-9
    • (2001) Clin. Pediatr. Emerg. Med , vol.4 , pp. 275-279
    • Altieri, M.F.1    Camarca, M.2
  • 2
    • 33751439870 scopus 로고    scopus 로고
    • Surface modification for enhancing antibody binding on polymer based microfluidic device for enzyme-linked immunosorbent assay
    • doi: 10.1021/la061123l
    • Y. Bai, C.G. Koh, M. Boreman, Y.-J. Juang, I.-C. Tang, L.J. Lee, S.-T. Yang, Surface modification for enhancing antibody binding on polymer based microfluidic device for enzyme-linked immunosorbent assay Langmuir 22, 9458-9467 (2006). doi: 10.1021/la061123l
    • (2006) Langmuir , vol.22 , pp. 9458-9467
    • Bai, Y.1    Koh, C.G.2    Boreman, M.3    Juang, Y.-J.4    Tang, I.-C.5    Lee, L.J.6    Yang, S.-T.7
  • 3
    • 18044390709 scopus 로고    scopus 로고
    • Microfluidic immunosensor system
    • doi: 10.1016/j.bios.2004.10.016
    • A. Bange, H.B. Halsall, W.R. Heineman, Microfluidic immunosensor system Biosens. Bioelectron 20, 2488-2503 (2005). doi: 10.1016/ j.bios.2004.10.016
    • (2005) Biosens. Bioelectron , vol.20 , pp. 2488-2503
    • Bange, A.1    Halsall, H.B.2    Heineman, W.R.3
  • 5
    • 0037060168 scopus 로고    scopus 로고
    • Polymer microfluidic devices
    • doi: 10.1016/S0039-9140(01)00594-X
    • H. Becker, L.E. Locascio, Polymer microfluidic devices Talanta 56(2), 267-287 (2002). doi: 10.1016/S0039-9140(01)00594-X
    • (2002) Talanta , vol.56 , Issue.2 , pp. 267-287
    • Becker, H.1    Locascio, L.E.2
  • 6
    • 33644753151 scopus 로고    scopus 로고
    • Redox mediation at 11-mercaptoundecanoic acid self-assembled monolayers on gold
    • doi: 10.1021/jp054290n
    • F. Cecchet, M. Marcaccio, M. Margotti, F. Paolucci, S. Rapino, P. Rudolf, Redox mediation at 11-mercaptoundecanoic acid self-assembled monolayers on gold J. Phys. Chem. B 110, 2241-2248 (2006). doi: 10.1021/ jp054290n
    • (2006) J. Phys. Chem. B , vol.110 , pp. 2241-2248
    • Cecchet, F.1    Marcaccio, M.2    Margotti, M.3    Paolucci, F.4    Rapino, S.5    Rudolf, P.6
  • 7
    • 0035884375 scopus 로고    scopus 로고
    • An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications
    • doi: 10.1021/ac010423z
    • M.L. Chabinyc, D.T. Chiu, J.C. McDonald, A.D. Stroock, An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications Anal. Chem. 73(18), 4491-4498 (2001). doi: 10.1021/ac010423z
    • (2001) Anal. Chem. , vol.73 , Issue.18 , pp. 4491-4498
    • Chabinyc, M.L.1    Chiu, D.T.2    McDonald, J.C.3    Stroock, A.D.4
  • 9
    • 68649097323 scopus 로고    scopus 로고
    • On-chip detection of myoglobin based on fluorescence
    • doi: 10.1016/j.bios.2008.09.004
    • F. Darain, P. Yager, K.L. Gan, S.C. Tjin, On-chip detection of myoglobin based on fluorescence. Biosens. Bioelectron. (2008). doi: 10.1016/ j.bios.2008.09.004
    • (2008) Biosens. Bioelectron.
    • Darain, F.1    Yager, P.2    Gan, K.L.3    Tjin, S.C.4
  • 10
    • 0038789253 scopus 로고    scopus 로고
    • Plastic fantastic?
    • A. de Mello, Plastic fantastic? Lab Chip 2, 31N-36N (2002)
    • (2002) Lab Chip , vol.2
    • de Mello, A.1
  • 11
    • 0004213320 scopus 로고    scopus 로고
    • E.P. Diamandis, T.K. Christopoulos (eds.) (Academic, New York)
    • E.P. Diamandis, T.K. Christopoulos (eds.), Immunoassay (Academic, New York, 1996)
    • (1996) Immunoassay
  • 12
    • 23144462800 scopus 로고    scopus 로고
    • A surface modification strategy on silicon nitride for developing biosensors
    • J. Diao, D. Ren, J.R. Engstrom, K.L. Lee, A surface modification strategy on silicon nitride for developing biosensors Anal. Biochem. 343, 322-328 (2005)
    • (2005) Anal. Biochem. , vol.343 , pp. 322-328
    • Diao, J.1    Ren, D.2    Engstrom, J.R.3    Lee, K.L.4
  • 13
    • 36348960605 scopus 로고    scopus 로고
    • Screen-printed microfluidic device for electrochemical immunoassay
    • H. Dong, C.-M. Li, Y.-F. Zhang, X.-D. Cao, Y. Gan, Screen-printed microfluidic device for electrochemical immunoassay Lab Chip 7, 1752-1758 (2007)
    • (2007) Lab Chip , vol.7 , pp. 1752-1758
    • Dong, H.1    Li, C.-M.2    Zhang, Y.-F.3    Cao, X.-D.4    Gan, Y.5
  • 14
    • 41149170592 scopus 로고    scopus 로고
    • Microchannel chips for the multiplexed analysis of human immunoglobulin G-antibody interactions by surface plasmon resonance imaging
    • Y. Dong, T. Wilkop, D. Xu, Z. Wang, Q. Cheng, Microchannel chips for the multiplexed analysis of human immunoglobulin G-antibody interactions by surface plasmon resonance imaging Anal. Bioanal. Chem. 390, 1575-1583 (2008)
    • (2008) Anal. Bioanal. Chem. , vol.390 , pp. 1575-1583
    • Dong, Y.1    Wilkop, T.2    Xu, D.3    Wang, Z.4    Cheng, Q.5
  • 15
    • 1242351491 scopus 로고    scopus 로고
    • Integrated microfluidic devices
    • D. Erickson, D. Li, Integrated microfluidic devices Anal. Chim. Acta 507(1), 11-26 (2004)
    • (2004) Anal. Chim. Acta , vol.507 , Issue.1 , pp. 11-26
    • Erickson, D.1    Li, D.2
  • 16
    • 0035152676 scopus 로고    scopus 로고
    • Development and characterization of an ELISA assay in PDMS microfluidic channels
    • E. Eteshola, D. Leckband, Development and characterization of an ELISA assay in PDMS microfluidic channels Sens. Actuat. B 72, 129-133 (2001)
    • (2001) Sens. Actuat. B , vol.72 , pp. 129-133
    • Eteshola, E.1    Leckband, D.2
  • 17
    • 21244500220 scopus 로고    scopus 로고
    • Permanently oriented anibody immobilization for digoxin determination with a flow-through fluoroimmunosensor
    • P. Fernandez, J.S. Durand, C. Perez-Conde, G. Paniagua, Permanently oriented anibody immobilization for digoxin determination with a flow-through fluoroimmunosensor Anal. Bioanal. Chem. 375, 1020-1023 (2003)
    • (2003) Anal. Bioanal. Chem. , vol.375 , pp. 1020-1023
    • Fernandez, P.1    Durand, J.S.2    Perez-Conde, C.3    Paniagua, G.4
  • 18
    • 1842866915 scopus 로고    scopus 로고
    • Nonlinear decrease of background fluorescence in polymer thin-films - A survey of materials and how they can complicate fluorescence detection in μTAS
    • K.R. Hawkins, P. Yager, Nonlinear decrease of background fluorescence in polymer thin-films - a survey of materials and how they can complicate fluorescence detection in μTAS Lab Chip 3, 248-252 (2003)
    • (2003) Lab Chip , vol.3 , pp. 248-252
    • Hawkins, K.R.1    Yager, P.2
  • 19
    • 0035902331 scopus 로고    scopus 로고
    • Electrochemical characterization of self-assembled alkylsiloxane monolayers on indium-tin oxide (ITO) semiconductor electrode
    • H. Hillebrandt, M. Tanaka, Electrochemical characterization of self-assembled alkylsiloxane monolayers on indium-tin oxide (ITO) semiconductor electrode J. Phys. Chem. B 105, 4270-4276 (2001)
    • (2001) J. Phys. Chem. B , vol.105 , pp. 4270-4276
    • Hillebrandt, H.1    Tanaka, M.2
  • 20
    • 8344272112 scopus 로고    scopus 로고
    • X-ray photoelectron spectroscopy and differential capacitance study of thiol-functional polysiloxane films on gold supports
    • P.A. Johnson, R. Levicky, X-ray photoelectron spectroscopy and differential capacitance study of thiol-functional polysiloxane films on gold supports Langmuir 20(22), 9621-9627 (2004)
    • (2004) Langmuir , vol.20 , Issue.22 , pp. 9621-9627
    • Johnson, P.A.1    Levicky, R.2
  • 21
    • 1042264193 scopus 로고    scopus 로고
    • Strategies for direct attachment of hapten to a polystyrene support for application in enzyme-linked immunosorbent assay (ELISA)
    • J. Kaur, K.V. Singh, M. Raje, G.C. Varshney, C.R. Suri, Strategies for direct attachment of hapten to a polystyrene support for application in enzyme-linked immunosorbent assay (ELISA) Anal. Chim. Acta 506, 133-135 (2004)
    • (2004) Anal. Chim. Acta , vol.506 , pp. 133-135
    • Kaur, J.1    Singh, K.V.2    Raje, M.3    Varshney, G.C.4    Suri, C.R.5
  • 22
    • 35348886709 scopus 로고    scopus 로고
    • Microfluidic systems integrated with two-dimensional surface plasmon resonance phase imaging systems for microarray immunoassay
    • K.-H. Lee, Y.-D. Su, S.-J. Chen, F.-G. Tseng, G.-B. Lee, Microfluidic systems integrated with two-dimensional surface plasmon resonance phase imaging systems for microarray immunoassay Biosens. Bioelectron. 23, 466-472 (2007)
    • (2007) Biosens. Bioelectron. , vol.23 , pp. 466-472
    • Lee, K.-H.1    Su, Y.-D.2    Chen, S.-J.3    Tseng, F.-G.4    Lee, G.-B.5
  • 23
    • 0038677414 scopus 로고    scopus 로고
    • F.S. Ligler, C.A. Rawe-Taitt (eds.) (Elsevier, Amsterdam)
    • F.S. Ligler, C.A. Rawe-Taitt (eds.), Optical Biosensor: Present and Future (Elsevier, Amsterdam, 2002)
    • (2002) Optical Biosensor: Present and Future
  • 24
    • 21844471002 scopus 로고    scopus 로고
    • Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods
    • P.V. Lode, Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods Clin. Biochem. 38(7), 591-606 (2005)
    • (2005) Clin. Biochem. , vol.38 , Issue.7 , pp. 591-606
    • Lode, P.V.1
  • 25
    • 0038656655 scopus 로고    scopus 로고
    • Engineering and characterization of polymer surfaces for biomedical applications
    • H.J. Mathieu, Y. Chevolot, L. Ruiz-Taylor, D. Leonard, Engineering and characterization of polymer surfaces for biomedical applications Adv. Polym. Sci. 162, 1-34 (2003)
    • (2003) Adv. Polym. Sci. , vol.162 , pp. 1-34
    • Mathieu, H.J.1    Chevolot, Y.2    Ruiz-Taylor, L.3    Leonard, D.4
  • 26
    • 33645868973 scopus 로고    scopus 로고
    • Determination of carbaryl in natural water samples by a surface plasmon resonance flow-through immunosensor
    • E. Mauriz, A. Calle, A. Abad, A. Montoya, A. Hildebrandt, D. Barcelo, L.M. Lechuga, Determination of carbaryl in natural water samples by a surface plasmon resonance flow-through immunosensor Biosens. Bioelectron. 21, 2129-2136 (2006)
    • (2006) Biosens. Bioelectron. , vol.21 , pp. 2129-2136
    • Mauriz, E.1    Calle, A.2    Abad, A.3    Montoya, A.4    Hildebrandt, A.5    Barcelo, D.6    Lechuga, L.M.7
  • 28
    • 0032807251 scopus 로고    scopus 로고
    • Identification of unacceptable background caused by non-specific protein adsorption to the plastic surface of 96-well immunoassay plates using a standardized enzyme-linked immunosorbant assay procedure
    • D.E. Rebeski, E.M. Winger, Y.K. Shin, M. Lehenta, M.M. Robinson, R. Verecka, J.R. Crowther, Identification of unacceptable background caused by non-specific protein adsorption to the plastic surface of 96-well immunoassay plates using a standardized enzyme-linked immunosorbant assay procedure J. Immunol. Methods 226, 85-92 (1999)
    • (1999) J. Immunol. Methods , vol.226 , pp. 85-92
    • Rebeski, D.E.1    Winger, E.M.2    Shin, Y.K.3    Lehenta, M.4    Robinson, M.M.5    Verecka, R.6    Crowther, J.R.7
  • 29
    • 0037090479 scopus 로고    scopus 로고
    • Cell lysis and protein extraction in a microfluidic device with detection by a fluorogenic enzyme assay
    • E.A. Schilling, A.E. Kamholz, P. Yager, Cell lysis and protein extraction in a microfluidic device with detection by a fluorogenic enzyme assay Anal. Chem. 74(8), 1798-1804 (2002)
    • (2002) Anal. Chem. , vol.74 , Issue.8 , pp. 1798-1804
    • Schilling, E.A.1    Kamholz, A.E.2    Yager, P.3
  • 30
    • 0033749295 scopus 로고    scopus 로고
    • Status of point-of-care testing: Promise, realities, and possibilities
    • P. St-Louis, Status of point-of-care testing: Promise, realities, and possibilities Clin. Biochem. 33(6), 427-440 (2000)
    • (2000) Clin. Biochem. , vol.33 , Issue.6 , pp. 427-440
    • St-Louis, P.1
  • 31
    • 0344562960 scopus 로고    scopus 로고
    • Self-assembled monolayer based piezoelectric crystal immunosensor for the quantification of total human immunoglobulin E
    • X.D. Su, F.T. Chew, S.F.Y. Li, Self-assembled monolayer based piezoelectric crystal immunosensor for the quantification of total human immunoglobulin E Anal. Biochem. 273, 66-72 (1999)
    • (1999) Anal. Biochem. , vol.273 , pp. 66-72
    • Su, X.D.1    Chew, F.T.2    Li, S.F.Y.3
  • 32
    • 32844463794 scopus 로고    scopus 로고
    • Impedance spectroscopy and affinity measurement of specific antibody-antigen interaction
    • A. Tlili, A. Abdelghani, S. Ameur, N. Jaffrezic-Renault, Impedance spectroscopy and affinity measurement of specific antibody-antigen interaction Mater. Sci. Eng. C 26, 546-550 (2006)
    • (2006) Mater. Sci. Eng. C , vol.26 , pp. 546-550
    • Tlili, A.1    Abdelghani, A.2    Ameur, S.3    Jaffrezic-Renault, N.4
  • 33
    • 39549109280 scopus 로고    scopus 로고
    • Microfluidic immunosensor based on stable antibody-patterned surface in PMMA microchip
    • H. Wang, S. Meng, K. Guo, Y. Liu, P. Yang, W.Z.B. Liu, Microfluidic immunosensor based on stable antibody-patterned surface in PMMA microchip Electrochem. Commun. 10(3), 447-450 (2008)
    • (2008) Electrochem. Commun. , vol.10 , Issue.3 , pp. 447-450
    • Wang, H.1    Meng, S.2    Guo, K.3    Liu, Y.4    Yang, P.5    Liu, W.Z.B.6
  • 35
    • 33947699860 scopus 로고    scopus 로고
    • Poly(vinyl alcohol) functionalized poly(dimethylsiloxane) solid surface for immunoassay
    • L. Yu, C.M. Li, Q. Zhou, J.H.T. Luong, Poly(vinyl alcohol) functionalized poly(dimethylsiloxane) solid surface for immunoassay Bioconjugate Chem 18(2), 281-284 (2007)
    • (2007) Bioconjugate Chem , vol.18 , Issue.2 , pp. 281-284
    • Yu, L.1    Li, C.M.2    Zhou, Q.3    Luong, J.H.T.4
  • 36
    • 34247637151 scopus 로고    scopus 로고
    • Functionalized nano interdigitated electrodes arrays on polymer with integrated microfluidics for direct bio-affinity sensing using impedimetric measurement
    • Z. Zou, J. Kai, M.J. Rust, J. Han, C.H. Ahn, Functionalized nano interdigitated electrodes arrays on polymer with integrated microfluidics for direct bio-affinity sensing using impedimetric measurement Sens. Actuat. A: Phys. 136(2), 518-526 (2007)
    • (2007) Sens. Actuat. A: Phys. , vol.136 , Issue.2 , pp. 518-526
    • Zou, Z.1    Kai, J.2    Rust, M.J.3    Han, J.4    Ahn, C.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.