메뉴 건너뛰기




Volumn 19, Issue 4, 2009, Pages

Cross-talk from adjacent muscle has a negligible effect on surface electromyographic activity of vastus intermedius muscle during isometric contraction

Author keywords

Cooling; Median frequency; Quadriceps femoris; Surface electromyogram; Vastus intermedius

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; COOLING; ELECTROMYOGRAPHY; HUMAN; HUMAN EXPERIMENT; KNEE; MALE; MUSCLE ISOMETRIC CONTRACTION; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUADRICEPS FEMORIS MUSCLE; VASTUS INTERMEDIUS MUSCLE; VASTUS LATERALIS MUSCLE; VOLUNTARY MOVEMENT;

EID: 67349146822     PISSN: 10506411     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jelekin.2008.06.002     Document Type: Article
Times cited : (41)

References (49)
  • 2
    • 0033976247 scopus 로고    scopus 로고
    • Quadriceps EMG/force relationship in knee extension and leg press
    • Alkner B.A., Tesch P.A., and Berg H.E. Quadriceps EMG/force relationship in knee extension and leg press. Med Sci Sport Exer 32 2 (2000) 459-463
    • (2000) Med Sci Sport Exer , vol.32 , Issue.2 , pp. 459-463
    • Alkner, B.A.1    Tesch, P.A.2    Berg, H.E.3
  • 4
    • 0015251373 scopus 로고
    • Integrated actions of four heads of quadriceps femoris: an electromyographic study
    • Basmajian J.V., Harden T.P., and Regenos E.M. Integrated actions of four heads of quadriceps femoris: an electromyographic study. Anat Rec 172 (1971) 15-20
    • (1971) Anat Rec , vol.172 , pp. 15-20
    • Basmajian, J.V.1    Harden, T.P.2    Regenos, E.M.3
  • 5
    • 38849148313 scopus 로고    scopus 로고
    • The effect of electrode placement and innervation zone location on the electromyographic amplitude and mean power frequency versus isometric torque relationship for vastus lateralis muscle
    • Beck T.W., Housh T.J., Cramer J.T., and Weir J.P. The effect of electrode placement and innervation zone location on the electromyographic amplitude and mean power frequency versus isometric torque relationship for vastus lateralis muscle. J Electromyogr Kinesiol 18 (2008) 317-328
    • (2008) J Electromyogr Kinesiol , vol.18 , pp. 317-328
    • Beck, T.W.1    Housh, T.J.2    Cramer, J.T.3    Weir, J.P.4
  • 6
    • 0037290922 scopus 로고    scopus 로고
    • EMG frequency content changes with increasing force and during fatigue in the quadriceps femoris muscle of men and women
    • Bilodeau M., Schindler-Ivens S., Williams D.M., Chandran R., and Sharma S.S. EMG frequency content changes with increasing force and during fatigue in the quadriceps femoris muscle of men and women. J Electromyogr Kinesiol 13 (2003) 83-92
    • (2003) J Electromyogr Kinesiol , vol.13 , pp. 83-92
    • Bilodeau, M.1    Schindler-Ivens, S.2    Williams, D.M.3    Chandran, R.4    Sharma, S.S.5
  • 7
    • 33747630490 scopus 로고    scopus 로고
    • Intra- and intermuscular variation in human quadriceps femoris architecture assessed in vivo
    • Blazevich A.J., Gill N.D., and Zhou S. Intra- and intermuscular variation in human quadriceps femoris architecture assessed in vivo. J Anat 209 (2006) 289-310
    • (2006) J Anat , vol.209 , pp. 289-310
    • Blazevich, A.J.1    Gill, N.D.2    Zhou, S.3
  • 9
    • 0030973129 scopus 로고    scopus 로고
    • The use of surface electromyography in biomechanics
    • DeLuca C.J. The use of surface electromyography in biomechanics. J Appl Biomech 13 (1997) 135-163
    • (1997) J Appl Biomech , vol.13 , pp. 135-163
    • DeLuca, C.J.1
  • 10
    • 67650528917 scopus 로고    scopus 로고
    • DeLuca C.J. (Ed), Wiley, New York
    • In: DeLuca C.J. (Ed). Electromyography (2006), Wiley, New York
    • (2006) Electromyography
  • 11
    • 0037290850 scopus 로고    scopus 로고
    • Interpretation of EMG changes with fatigue: facts, pitfalls, and fallacies
    • Dimitrova N.A., and Dimitrov G.V. Interpretation of EMG changes with fatigue: facts, pitfalls, and fallacies. J Electromyogr Kinesiol 13 (2003) 13-36
    • (2003) J Electromyogr Kinesiol , vol.13 , pp. 13-36
    • Dimitrova, N.A.1    Dimitrov, G.V.2
  • 13
    • 0016746337 scopus 로고
    • Muscle fibre type populations of human leg muscles
    • Edgerton V.R., Smith J.L., and Simpson D.R. Muscle fibre type populations of human leg muscles. Histochem J 7 (1975) 259-266
    • (1975) Histochem J , vol.7 , pp. 259-266
    • Edgerton, V.R.1    Smith, J.L.2    Simpson, D.R.3
  • 15
    • 0036092520 scopus 로고    scopus 로고
    • Motor unit recruitment strategies investigated by surface EMG variables
    • Farina D., Fosci M., and Merletti R. Motor unit recruitment strategies investigated by surface EMG variables. J Appl Physiol 92 1 (2002) 235-247
    • (2002) J Appl Physiol , vol.92 , Issue.1 , pp. 235-247
    • Farina, D.1    Fosci, M.2    Merletti, R.3
  • 16
    • 0026601540 scopus 로고
    • Effects of temperature on the maximal instantaneous muscle power of humans
    • Ferretti G., Ishii M., and Cerretelli P. Effects of temperature on the maximal instantaneous muscle power of humans. Eur J Appl Physiol Occup Physiol 64 (1992) 112-116
    • (1992) Eur J Appl Physiol Occup Physiol , vol.64 , pp. 112-116
    • Ferretti, G.1    Ishii, M.2    Cerretelli, P.3
  • 18
    • 0025915061 scopus 로고
    • Dependence of the mean power frequency of the electromyogram on muscle force and fibre type
    • Gerdle B., Henriksson-Larsen K., Lorentzon R., and Wrestling M.L. Dependence of the mean power frequency of the electromyogram on muscle force and fibre type. Acta Physiol Scand 142 (1991) 457-465
    • (1991) Acta Physiol Scand , vol.142 , pp. 457-465
    • Gerdle, B.1    Henriksson-Larsen, K.2    Lorentzon, R.3    Wrestling, M.L.4
  • 19
    • 0026726635 scopus 로고
    • Interpretation of EMG spectral alterations and alteration indexes at sustained contraction
    • Hagg G.M. Interpretation of EMG spectral alterations and alteration indexes at sustained contraction. J Appl Physiol 73 4 (1992) 1211-1217
    • (1992) J Appl Physiol , vol.73 , Issue.4 , pp. 1211-1217
    • Hagg, G.M.1
  • 20
    • 0033813270 scopus 로고    scopus 로고
    • Development of recommendations for SEMG sensors and sensor placement procedures
    • Hermens H.J., Freriks B., Disselhorst-Klug C., and Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol 10 (2000) 361-374
    • (2000) J Electromyogr Kinesiol , vol.10 , pp. 361-374
    • Hermens, H.J.1    Freriks, B.2    Disselhorst-Klug, C.3    Rau, G.4
  • 21
    • 0032191629 scopus 로고    scopus 로고
    • Variability of some SEMG parameter estimates with electrode location
    • Hogrel J.-Y., Duchene J., and Marini J.-F. Variability of some SEMG parameter estimates with electrode location. J Electromyogr Kinesiol 8 (1998) 305-315
    • (1998) J Electromyogr Kinesiol , vol.8 , pp. 305-315
    • Hogrel, J.-Y.1    Duchene, J.2    Marini, J.-F.3
  • 22
    • 0026461117 scopus 로고
    • Effect of temperature on electromyogram and muscle function
    • Holewijn M., and Heus R. Effect of temperature on electromyogram and muscle function. Eur J Appl Physiol Occup Physiol 65 (1992) 541-545
    • (1992) Eur J Appl Physiol Occup Physiol , vol.65 , pp. 541-545
    • Holewijn, M.1    Heus, R.2
  • 23
    • 33847745058 scopus 로고    scopus 로고
    • Sensitivity of the cross-correlation between simulated surface EMGs for two muscles to detect motor unit synchronization
    • Keenan K.G., Farina D., Meyer F.G., Merletti R., and Enoka R.M. Sensitivity of the cross-correlation between simulated surface EMGs for two muscles to detect motor unit synchronization. J Appl Physiol 102 (2007) 1193-1201
    • (2007) J Appl Physiol , vol.102 , pp. 1193-1201
    • Keenan, K.G.1    Farina, D.2    Meyer, F.G.3    Merletti, R.4    Enoka, R.M.5
  • 24
    • 28544451326 scopus 로고    scopus 로고
    • The effect of ice application over the vastus medialis on the activity of the quadriceps femoris assessed by muscle function magnetic resonance imaging
    • Kinugasa R., Yoshida K., and Horii A. The effect of ice application over the vastus medialis on the activity of the quadriceps femoris assessed by muscle function magnetic resonance imaging. J Sport Med Phys Fit 45 (2005) 360-364
    • (2005) J Sport Med Phys Fit , vol.45 , pp. 360-364
    • Kinugasa, R.1    Yoshida, K.2    Horii, A.3
  • 25
    • 18244385751 scopus 로고    scopus 로고
    • Skin cooling alters the activation patterns of different heads of the quadriceps
    • Kinugasa R., Yoshida K., Watanabe T., Kuchiki K., and Horii A. Skin cooling alters the activation patterns of different heads of the quadriceps. Can J Appl Physiol 30 2 (2005) 127-139
    • (2005) Can J Appl Physiol , vol.30 , Issue.2 , pp. 127-139
    • Kinugasa, R.1    Yoshida, K.2    Watanabe, T.3    Kuchiki, K.4    Horii, A.5
  • 26
    • 33748473855 scopus 로고    scopus 로고
    • The frequency of alternate muscle activity is associated with attenuation in muscle fatigue
    • Kouzaki M., and Shinohara M. The frequency of alternate muscle activity is associated with attenuation in muscle fatigue. J Appl Physiol 101 (2006) 715-720
    • (2006) J Appl Physiol , vol.101 , pp. 715-720
    • Kouzaki, M.1    Shinohara, M.2
  • 27
    • 0033770687 scopus 로고    scopus 로고
    • Decrease in maximal voluntary contraction by tonic vibration applied to a single synergist muscle in humans
    • Kouzaki M., Shinohara M., and Fukunaga T. Decrease in maximal voluntary contraction by tonic vibration applied to a single synergist muscle in humans. J Appl Physiol 89 (2000) 1420-1424
    • (2000) J Appl Physiol , vol.89 , pp. 1420-1424
    • Kouzaki, M.1    Shinohara, M.2    Fukunaga, T.3
  • 28
    • 0029150437 scopus 로고
    • Effect of muscle fiber type and size on EMG median frequency and conduction velocity
    • Kupa E.J., Roy S.H., Kandarian S.C., and Luca C.J.D. Effect of muscle fiber type and size on EMG median frequency and conduction velocity. J Appl Physiol 79 1 (1995) 23-32
    • (1995) J Appl Physiol , vol.79 , Issue.1 , pp. 23-32
    • Kupa, E.J.1    Roy, S.H.2    Kandarian, S.C.3    Luca, C.J.D.4
  • 29
    • 0014377378 scopus 로고
    • Quadriceps function: an anatomical and mechanical study using amputated limbs
    • Lieb F.J., and Perry J. Quadriceps function: an anatomical and mechanical study using amputated limbs. J Bone Joint Surg A 50 (1968) 1535-1548
    • (1968) J Bone Joint Surg A , vol.50 , pp. 1535-1548
    • Lieb, F.J.1    Perry, J.2
  • 30
    • 0015077003 scopus 로고
    • Quadriceps function: an electromyographic study under isometric contraction
    • Lieb F.J., and Perry J. Quadriceps function: an electromyographic study under isometric contraction. J Bone Joint Surg A 53 4 (1971) 749-758
    • (1971) J Bone Joint Surg A , vol.53 , Issue.4 , pp. 749-758
    • Lieb, F.J.1    Perry, J.2
  • 31
    • 0037377618 scopus 로고    scopus 로고
    • A simulation study to examine the use of cross-correlation as an estimate of surface EMG cross talk
    • Lowery M.M., Stoykov N.S., and Kuiken T.A. A simulation study to examine the use of cross-correlation as an estimate of surface EMG cross talk. J Appl Physiol 94 (2003) 1324-1334
    • (2003) J Appl Physiol , vol.94 , pp. 1324-1334
    • Lowery, M.M.1    Stoykov, N.S.2    Kuiken, T.A.3
  • 32
    • 0023241621 scopus 로고
    • a B Voluntary control of motor units in human antagonist muscles: coactivation and reciprocal activation
    • Manbrito C.J.D. a B Voluntary control of motor units in human antagonist muscles: coactivation and reciprocal activation. J Neurophysiol 58 3 (1987) 525-542
    • (1987) J Neurophysiol , vol.58 , Issue.3 , pp. 525-542
    • Manbrito, C.J.D.1
  • 33
    • 20444401125 scopus 로고    scopus 로고
    • Motor unit synchronization between medial and lateral vasti muscles
    • Mellor R., and Hodges P. Motor unit synchronization between medial and lateral vasti muscles. Clin Neurophysiol 116 (2005) 1585-1595
    • (2005) Clin Neurophysiol , vol.116 , pp. 1585-1595
    • Mellor, R.1    Hodges, P.2
  • 34
    • 0021272508 scopus 로고
    • Median frequency of the myoelectric signal effect of muscle ischemia and cooling
    • Merletti R., Sabbahi M.A., and DeLuca C.J. Median frequency of the myoelectric signal effect of muscle ischemia and cooling. Eur J Appl Physiol Occup Physiol 52 (1984) 258-265
    • (1984) Eur J Appl Physiol Occup Physiol , vol.52 , pp. 258-265
    • Merletti, R.1    Sabbahi, M.A.2    DeLuca, C.J.3
  • 35
    • 0001236387 scopus 로고
    • The effects of ice and compression wraps on intramuscular temperatures at various depth
    • Merrick M.A., Knight K.L., Ingersoll C.D., and Potteiger J.A. The effects of ice and compression wraps on intramuscular temperatures at various depth. J Athl Training 28 3 (1993) 237-245
    • (1993) J Athl Training , vol.28 , Issue.3 , pp. 237-245
    • Merrick, M.A.1    Knight, K.L.2    Ingersoll, C.D.3    Potteiger, J.A.4
  • 36
    • 2542588541 scopus 로고    scopus 로고
    • Precision of measurements of physical workload during standardised manual handling. Part I: surface electromyography of m. trapezius, m. infraspinatus and the forearm extensors
    • Nordander C., Balogh I., Mathiassen S.E., Ohlsson K., Unge J., Skerfving S., et al. Precision of measurements of physical workload during standardised manual handling. Part I: surface electromyography of m. trapezius, m. infraspinatus and the forearm extensors. J Electromyogr Kinesiol 14 4 (2004) 443-454
    • (2004) J Electromyogr Kinesiol , vol.14 , Issue.4 , pp. 443-454
    • Nordander, C.1    Balogh, I.2    Mathiassen, S.E.3    Ohlsson, K.4    Unge, J.5    Skerfving, S.6
  • 37
    • 20444426274 scopus 로고    scopus 로고
    • Repeatability of surface EMG parameters at various isometric contraction levels and during fatigue using bipolar and Laplacian electrode configurations
    • Ollivier K., Portero P., Maisetti O., and Hogrel J.Y. Repeatability of surface EMG parameters at various isometric contraction levels and during fatigue using bipolar and Laplacian electrode configurations. J Electromyogr Kinesiol 15 5 (2005) 466-473
    • (2005) J Electromyogr Kinesiol , vol.15 , Issue.5 , pp. 466-473
    • Ollivier, K.1    Portero, P.2    Maisetti, O.3    Hogrel, J.Y.4
  • 38
    • 27744524367 scopus 로고    scopus 로고
    • Muscle temperature and EMG amplitude and frequency
    • Petrofsky J., and Laymon M. Muscle temperature and EMG amplitude and frequency. Aviat Space Environ Med 76 11 (2005) 1024-1030
    • (2005) Aviat Space Environ Med , vol.76 , Issue.11 , pp. 1024-1030
    • Petrofsky, J.1    Laymon, M.2
  • 39
    • 0018886537 scopus 로고
    • The influence of temperature on the amplitude and frequency components of the EMG during brief and sustained Isometric contractions
    • Petrofsky J.S., and Lind A.R. The influence of temperature on the amplitude and frequency components of the EMG during brief and sustained Isometric contractions. Eur J Appl Physiol Occup Physiol 44 (1980) 189-200
    • (1980) Eur J Appl Physiol Occup Physiol , vol.44 , pp. 189-200
    • Petrofsky, J.S.1    Lind, A.R.2
  • 40
    • 0034004773 scopus 로고    scopus 로고
    • Activation linearity and parallelism of the superficial quadriceps across the isometric intensity spectrum
    • Pincivero D.M., and Coelho A.J. Activation linearity and parallelism of the superficial quadriceps across the isometric intensity spectrum. Muscle Nerve 23 (2000) 393-398
    • (2000) Muscle Nerve , vol.23 , pp. 393-398
    • Pincivero, D.M.1    Coelho, A.J.2
  • 41
    • 0034018466 scopus 로고    scopus 로고
    • Gender and muscle differences in EMG amplitude and median frequency, and variability during maximal voluntary contractions of the quadriceps femoris
    • Pincivero D.M., Green R.C., Mark J.D., and Campy R.M. Gender and muscle differences in EMG amplitude and median frequency, and variability during maximal voluntary contractions of the quadriceps femoris. J Electromyogr Kinesiol 10 (2000) 189-196
    • (2000) J Electromyogr Kinesiol , vol.10 , pp. 189-196
    • Pincivero, D.M.1    Green, R.C.2    Mark, J.D.3    Campy, R.M.4
  • 42
    • 33749368351 scopus 로고    scopus 로고
    • Synergists activation pattern of the quadriceps muscle differs when performing sustained isometric contractions with different EMG biofeedback
    • Place N., Matkowski B., Martin A., and Lepers R. Synergists activation pattern of the quadriceps muscle differs when performing sustained isometric contractions with different EMG biofeedback. Exp Brain Res 174 (2006) 595-603
    • (2006) Exp Brain Res , vol.174 , pp. 595-603
    • Place, N.1    Matkowski, B.2    Martin, A.3    Lepers, R.4
  • 43
    • 0022995453 scopus 로고
    • Effects of electrode location on myoelectric conduction velocity and median frequency estimates
    • Roy S.H., DeLuca C.J., and Schneider J. Effects of electrode location on myoelectric conduction velocity and median frequency estimates. J Appl Physiol 61 4 (1986) 1510-1517
    • (1986) J Appl Physiol , vol.61 , Issue.4 , pp. 1510-1517
    • Roy, S.H.1    DeLuca, C.J.2    Schneider, J.3
  • 45
    • 0344237284 scopus 로고    scopus 로고
    • Local tissue temperature effects on peak torque and muscular endurance during isometric knee extension
    • Thornley L.J., Maxwell N.S., and Cheung S.S. Local tissue temperature effects on peak torque and muscular endurance during isometric knee extension. Eur J Appl Physiol 90 (2003) 588-594
    • (2003) Eur J Appl Physiol , vol.90 , pp. 588-594
    • Thornley, L.J.1    Maxwell, N.S.2    Cheung, S.S.3
  • 46
    • 0028323039 scopus 로고
    • Cross talk in surface electromyography: theoretical and practical estimates
    • Winter D.A., Fuglevand A.J., and Archer S.E. Cross talk in surface electromyography: theoretical and practical estimates. J Electromyogr Kinesiol 4 1 (1994) 15-26
    • (1994) J Electromyogr Kinesiol , vol.4 , Issue.1 , pp. 15-26
    • Winter, D.A.1    Fuglevand, A.J.2    Archer, S.E.3
  • 48
    • 0038066674 scopus 로고    scopus 로고
    • In vivo load sharing among the quadriceps components
    • Zhang L.-Q., Wang G., Nuber G.W., and Press J.M. In vivo load sharing among the quadriceps components. J Orthopaed Res 21 (2003) 565-571
    • (2003) J Orthopaed Res , vol.21 , pp. 565-571
    • Zhang, L.-Q.1    Wang, G.2    Nuber, G.W.3    Press, J.M.4
  • 49
    • 0018017629 scopus 로고
    • Effect of electrode parameters on the bandwidth of the surface e.m.g. power-density spectrum
    • Zipp P. Effect of electrode parameters on the bandwidth of the surface e.m.g. power-density spectrum. Med Biol Eng Comput 16 (1978) 537-541
    • (1978) Med Biol Eng Comput , vol.16 , pp. 537-541
    • Zipp, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.