메뉴 건너뛰기




Volumn 5, Issue 5, 2009, Pages 1831-1837

Fabrication of compositionally and structurally graded Ti-TiO2 structures using laser engineered net shaping (LENS)

Author keywords

Biocompatibility; Functionally graded materials; Laser engineered net shaping (LENS); Laser processing; Osteoblast

Indexed keywords

FRICTION; FUNCTIONALLY GRADED MATERIALS; HIP PROSTHESES; TITANIUM DIOXIDE; WETTING;

EID: 67349144099     PISSN: 17427061     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.actbio.2009.01.011     Document Type: Article
Times cited : (169)

References (24)
  • 1
    • 0026660573 scopus 로고
    • Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty
    • Cooper R.A., McAllister C.M., Borden L.S., and Bauer T.W. Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty. J Arthroplasty 7 (1992) 285-290
    • (1992) J Arthroplasty , vol.7 , pp. 285-290
    • Cooper, R.A.1    McAllister, C.M.2    Borden, L.S.3    Bauer, T.W.4
  • 2
    • 0000858076 scopus 로고
    • The role of small polyethylene wear particles in inducing the release of mediators known to stimulate bone resorption
    • Howie D.W., Rogers S.D., Haynes D.R., and Pearcy M.J. The role of small polyethylene wear particles in inducing the release of mediators known to stimulate bone resorption. Trans Orthop Res Soc 19 (1994) 201-208
    • (1994) Trans Orthop Res Soc , vol.19 , pp. 201-208
    • Howie, D.W.1    Rogers, S.D.2    Haynes, D.R.3    Pearcy, M.J.4
  • 4
    • 0035482038 scopus 로고    scopus 로고
    • Mechanical behaviour, wear surface morphology, and clinical performance of UHMWPE acetabular components after 10 years of implantation
    • Edidin A.A., Rimnac C.M., Goldberg V.M., and Kurtz S.M. Mechanical behaviour, wear surface morphology, and clinical performance of UHMWPE acetabular components after 10 years of implantation. Wear 250 (2001) 152-158
    • (2001) Wear , vol.250 , pp. 152-158
    • Edidin, A.A.1    Rimnac, C.M.2    Goldberg, V.M.3    Kurtz, S.M.4
  • 5
    • 0023007566 scopus 로고
    • The effect of conformity, thickness, and material on stresses in ultrahigh molecular weight components for total joint replacement
    • Bartel D.L., Bicknell V.L., and Wright T.M. The effect of conformity, thickness, and material on stresses in ultrahigh molecular weight components for total joint replacement. J Bone Joint Surg 68A (1986) 1041-1051
    • (1986) J Bone Joint Surg , vol.68 A , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 6
    • 0035175940 scopus 로고    scopus 로고
    • Relationship between gravimetric wear and particle generation in hip simulators: conventional compared with cross linked polyethylene
    • Ries M.D., Scott M.L., and Jani S. Relationship between gravimetric wear and particle generation in hip simulators: conventional compared with cross linked polyethylene. J Bone Joint Surg 83A Suppl. 2 (2001) 116-122
    • (2001) J Bone Joint Surg , vol.83 A , Issue.SUPPL. 2 , pp. 116-122
    • Ries, M.D.1    Scott, M.L.2    Jani, S.3
  • 7
    • 0036555516 scopus 로고    scopus 로고
    • In vivo tribological performance of 231 metal-on-metal hip articulations
    • Rieker C., and Kottig P. In vivo tribological performance of 231 metal-on-metal hip articulations. Hip Int 12 (2002) 73-76
    • (2002) Hip Int , vol.12 , pp. 73-76
    • Rieker, C.1    Kottig, P.2
  • 8
    • 5344237410 scopus 로고    scopus 로고
    • Metal-on-metal versus metal-on-polyethylene bearings in total hip arthroplasty: a matched case-control study
    • Douglas N., Christopher P.R., Javad P., Daniel J.B., Stefan E., and Andre B. Metal-on-metal versus metal-on-polyethylene bearings in total hip arthroplasty: a matched case-control study. J Arthroplasty 19 7, Suppl. 2 (2004) 35-41
    • (2004) J Arthroplasty , vol.19 , Issue.7 SUPPL. 2 , pp. 35-41
    • Douglas, N.1    Christopher, P.R.2    Javad, P.3    Daniel, J.B.4    Stefan, E.5    Andre, B.6
  • 10
    • 0029421937 scopus 로고
    • The influence of scratches to metallic counterfaces on the wear of ultra-high molecular weight polyethylene
    • Fisher J., Firkins P., Reeves E.A., Hailey J.L., and Isaac G.H. The influence of scratches to metallic counterfaces on the wear of ultra-high molecular weight polyethylene. Proc Inst Mech Eng [H] 209 (1995) 263-264
    • (1995) Proc Inst Mech Eng [H] , vol.209 , pp. 263-264
    • Fisher, J.1    Firkins, P.2    Reeves, E.A.3    Hailey, J.L.4    Isaac, G.H.5
  • 11
    • 0023425006 scopus 로고
    • The role of counterface imperfections in the wear of polyethylene
    • Dowson D., Taheri S., and Wallbridge N.C. The role of counterface imperfections in the wear of polyethylene. Wear 119 (1987) 277-293
    • (1987) Wear , vol.119 , pp. 277-293
    • Dowson, D.1    Taheri, S.2    Wallbridge, N.C.3
  • 12
    • 0027244880 scopus 로고
    • Characteristics of metal and ceramic total hip bearing surfaces and their effect on long term ultra high molecular weight PE wear
    • Davidson J.A. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long term ultra high molecular weight PE wear. Clin Orthop 294 (1993) 361-378
    • (1993) Clin Orthop , vol.294 , pp. 361-378
    • Davidson, J.A.1
  • 13
    • 8944247638 scopus 로고
    • Adsorption and lubrication
    • Mori S. Adsorption and lubrication. J Tribol 36 (1991) 161
    • (1991) J Tribol , vol.36 , pp. 161
    • Mori, S.1
  • 14
    • 0024702265 scopus 로고
    • Tribochemical mechanism of alumina with water
    • Gates R., Hsu S., and Klaus E. Tribochemical mechanism of alumina with water. STLE Trib Trans 32 (1989) 357
    • (1989) STLE Trib Trans , vol.32 , pp. 357
    • Gates, R.1    Hsu, S.2    Klaus, E.3
  • 15
    • 0017513553 scopus 로고
    • New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminium oxide ceramic/metal
    • Semlitsch M., Tehmann M., Weber H., Dorre E., and Willert H.G. New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminium oxide ceramic/metal. J Biomed Mater Res 11 (1977) 537-552
    • (1977) J Biomed Mater Res , vol.11 , pp. 537-552
    • Semlitsch, M.1    Tehmann, M.2    Weber, H.3    Dorre, E.4    Willert, H.G.5
  • 16
    • 34548523637 scopus 로고    scopus 로고
    • Processing and biocompatibility evaluation of laser processed porous titanium
    • Xue W., Balla V.K., Bandyopadhyay A., and Bose S. Processing and biocompatibility evaluation of laser processed porous titanium. Acta Biomater 3 (2007) 1007-1018
    • (2007) Acta Biomater , vol.3 , pp. 1007-1018
    • Xue, W.1    Balla, V.K.2    Bandyopadhyay, A.3    Bose, S.4
  • 17
    • 41549130704 scopus 로고    scopus 로고
    • Functionally graded Co-Cr-Mo coating on Ti-6Al-4V alloy structures
    • Vamsi Krishna B., Xue W., Bose S., and Bandyopadhyay A. Functionally graded Co-Cr-Mo coating on Ti-6Al-4V alloy structures. Acta Biomater 4 (2008) 697-706
    • (2008) Acta Biomater , vol.4 , pp. 697-706
    • Vamsi Krishna, B.1    Xue, W.2    Bose, S.3    Bandyopadhyay, A.4
  • 18
    • 0025449531 scopus 로고
    • Solutions able to reproduce in vivo surface-structure changes in bioactive glass-ceramic A-W3
    • Kokubo T., Kushitani H., Sakka S., Kitsugi T., and Yamamuro T. Solutions able to reproduce in vivo surface-structure changes in bioactive glass-ceramic A-W3. J Biomed Mater Res 24 (1990) 721-734
    • (1990) J Biomed Mater Res , vol.24 , pp. 721-734
    • Kokubo, T.1    Kushitani, H.2    Sakka, S.3    Kitsugi, T.4    Yamamuro, T.5
  • 20
    • 34548541841 scopus 로고    scopus 로고
    • Low stiffness porous Ti structures for load-bearing implants
    • Vamsi Krishna B., Bose S., and Bandyopadhyay A. Low stiffness porous Ti structures for load-bearing implants. Acta Biomater 3 (2007) 997-1006
    • (2007) Acta Biomater , vol.3 , pp. 997-1006
    • Vamsi Krishna, B.1    Bose, S.2    Bandyopadhyay, A.3
  • 23
    • 33645141788 scopus 로고    scopus 로고
    • Effects of Nd:YAG laser treatment on the wettability characteristics of a zirconia-based bioceramic
    • Hao L., and Lawrence J. Effects of Nd:YAG laser treatment on the wettability characteristics of a zirconia-based bioceramic. Opt Lasers Eng 44 (2006) 803-814
    • (2006) Opt Lasers Eng , vol.44 , pp. 803-814
    • Hao, L.1    Lawrence, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.