메뉴 건너뛰기




Volumn 13, Issue 2, 2008, Pages

Influence of tissue optical properties on laser Doppler perfusion imaging, accounting for photon penetration depth and the laser speckle phenomenon

Author keywords

coherence area; depth sensitivity; laser Doppler perfusion imaging; Monte Carlo simulations; sampling depth; tissue optical properties

Indexed keywords

ABSORPTION LEVELS; BEAM DIAMETERS; DEPTH SENSITIVITY; IN-VIVO; LASER DOPPLER PERFUSION IMAGING; LASER SPECKLE; LOW CONCENTRATIONS; MONTE CARLO SIMULATION; MOVING PARTICLES; NORMAL SKIN; PHOTON PENETRATION; PHOTON STATISTICS; PORT WINE STAINS; SCATTERING LEVELS; SIGNAL RESPONSE; SPECKLE SIZE; TISSUE OPTICAL PROPERTIES; TURBID MEDIUM;

EID: 49649091827     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.2904958     Document Type: Article
Times cited : (19)

References (17)
  • 1
    • 0000646850 scopus 로고
    • Evaluation of blood flow by laser speckle image sensing: Part 1
    • apo APOPAI 0003-6935
    • H., Fujii, K., Nohira, Y., Yamamoto, H., Ikawa, and T., Ohura, " Evaluation of blood flow by laser speckle image sensing: part 1, ", Appl. Opt., 26, 5321-5325 (1987). apo APOPAI 0003-6935
    • (1987) Appl. Opt. , vol.26 , pp. 5321-5325
    • Fujii, H.1    Nohira, K.2    Yamamoto, Y.3    Ikawa, H.4    Ohura, T.5
  • 2
    • 0029293756 scopus 로고
    • Quasi-real time digital version of single-exposure speckle photography for full-field monitoring of velocity or flow fields
    • opc OPCOB8 0030-4018 10.1016/0030-4018(95)00042-7
    • J. D., Briers and S., Webster, " Quasi-real time digital version of single-exposure speckle photography for full-field monitoring of velocity or flow fields, ", Opt. Commun., 116, 36-42 (1995). opc OPCOB8 0030-4018 10.1016/0030-4018(95)00042-7
    • (1995) Opt. Commun. , vol.116 , pp. 36-42
    • Briers, J.D.1    Webster, S.2
  • 3
    • 0026156875 scopus 로고
    • A laser Doppler scanner for imaging blood flow in skin
    • jie JBIEDR 0141-5425 10.1016/0141-5425(91)90125-Q
    • T. J. H., Essex and P. O., Byrne, " A laser Doppler scanner for imaging blood flow in skin, ", J. Biomed. Eng., 13, 189-194 (1991). jie JBIEDR 0141-5425 10.1016/0141-5425(91)90125-Q
    • (1991) J. Biomed. Eng. , vol.13 , pp. 189-194
    • Essex, T.J.H.1    Byrne, P.O.2
  • 4
    • 0027573492 scopus 로고
    • Laser Doppler perfusion imaging by dynamic light scattering
    • ieb IEBEAX 0018-9294 10.1109/10.222322
    • K., Wårdell, A., Jakobsson, and G. E., Nilsson, " Laser Doppler perfusion imaging by dynamic light scattering, ", IEEE Trans. Biomed. Eng., 40, 309-316 (1993). ieb IEBEAX 0018-9294 10.1109/10.222322
    • (1993) IEEE Trans. Biomed. Eng. , vol.40 , pp. 309-316
    • Wårdell, K.1    Jakobsson, A.2    Nilsson, G.E.3
  • 5
    • 0001400289 scopus 로고
    • Scattering and imaging with diffusing temporal field correlations
    • prl PRLTAO 0031-9007 10.1103/PhysRevLett.75.1855
    • D. A., Boas, L. E., Campbell, and A. G., Yodh, " Scattering and imaging with diffusing temporal field correlations, ", Phys. Rev. Lett., 75, 1855-1858 (1995). prl PRLTAO 0031-9007 10.1103/PhysRevLett.75.1855
    • (1995) Phys. Rev. Lett. , vol.75 , pp. 1855-1858
    • Boas, D.A.1    Campbell, L.E.2    Yodh, A.G.3
  • 6
    • 0000099185 scopus 로고    scopus 로고
    • Laser Doppler and time-varying speckle: A conciliation
    • joa JOAOD6 0740-3232
    • J. D., Briers, " Laser Doppler and time-varying speckle: a conciliation, ", J. Opt. Soc. Am. A, 13, 345-350 (1996). joa JOAOD6 0740-3232
    • (1996) J. Opt. Soc. Am. A , vol.13 , pp. 345-350
    • Briers, J.D.1
  • 7
    • 33644926431 scopus 로고    scopus 로고
    • Speckles in laser Doppler perfusion imaging
    • opl OPLEDP 0146-9592 10.1364/OL.31.000468
    • V., Rajan, B., Varghese, T. G., van Leeuwen, and W., Steenbergen, " Speckles in laser Doppler perfusion imaging, ", Opt. Lett., 31, 468-470 (2006). opl OPLEDP 0146-9592 10.1364/OL.31.000468
    • (2006) Opt. Lett. , vol.31 , pp. 468-470
    • Rajan, V.1    Varghese, B.2    Van Leeuwen, T.G.3    Steenbergen, W.4
  • 8
    • 0036099795 scopus 로고    scopus 로고
    • Skin irritation typing and grading based on laser Doppler perfusion imaging
    • b5r ZZZZZZ 0909-752X
    • A., Fullerton, B., Rode, and J., Serup, " Skin irritation typing and grading based on laser Doppler perfusion imaging, ", Skin Res. Technol., 8, 23-31 (2002). b5r ZZZZZZ 0909-752X
    • (2002) Skin Res. Technol. , vol.8 , pp. 23-31
    • Fullerton, A.1    Rode, B.2    Serup, J.3
  • 9
    • 0034879980 scopus 로고    scopus 로고
    • Measurement of depth of burns by laser Doppler perfusion Imaging
    • 33s ZZZZZZ 0305-4179
    • E. J., Droog, W., Steenbergen, and F., Sjöberg, " Measurement of depth of burns by laser Doppler perfusion Imaging, ", Burns, 27, 561-568 (2001). 33s ZZZZZZ 0305-4179
    • (2001) Burns , vol.27 , pp. 561-568
    • Droog, E.J.1    Steenbergen, W.2    Sjöberg, F.3
  • 10
    • 34547366579 scopus 로고    scopus 로고
    • Quantification of spatial intensity correlations and photodetector intensity fluctuations of coherent light reflected from turbid particle suspensions
    • pre PLEEE8 1063-651X 10.1103/PhysRevE.75.060901
    • V., Rajan, B., Varghese, T. G., van Leeuwen, and W., Steenbergen, " Quantification of spatial intensity correlations and photodetector intensity fluctuations of coherent light reflected from turbid particle suspensions, ", Phys. Rev. E, 75, 060901-4 (2007). pre PLEEE8 1063-651X 10.1103/PhysRevE.75.060901
    • (2007) Phys. Rev. e , vol.75 , pp. 060901-4
    • Rajan, V.1    Varghese, B.2    Van Leeuwen, T.G.3    Steenbergen, W.4
  • 11
    • 0019583049 scopus 로고
    • Model for laser Doppler measurements of blood flow in tissue
    • apo APOPAI 0003-6935
    • R., Bonner and R., Nossal, " Model for laser Doppler measurements of blood flow in tissue, ", Appl. Opt., 20, 2097-2107 (1981). apo APOPAI 0003-6935
    • (1981) Appl. Opt. , vol.20 , pp. 2097-2107
    • Bonner, R.1    Nossal, R.2
  • 12
    • 84887196567 scopus 로고
    • Laser Doppler velocimetry and Monte Carlo simulations on models for blood perfusion in tissue
    • apo APOPAI 0003-6935
    • F. F. M., de Mul, M. H., Koelink, M. L., Kok, P. J., Harmsma, J., Greve, R., Graaff, and J. G., Aarnoudse, " Laser Doppler velocimetry and Monte Carlo simulations on models for blood perfusion in tissue, ", Appl. Opt., 34, 6595-6611 (1995). apo APOPAI 0003-6935
    • (1995) Appl. Opt. , vol.34 , pp. 6595-6611
    • De Mul, F.F.M.1    Koelink, M.H.2    Kok, M.L.3    Harmsma, P.J.4    Greve, J.5    Graaff, R.6    Aarnoudse, J.G.7
  • 13
    • 12844262369 scopus 로고    scopus 로고
    • Photoacoustic imaging of blood vessels with a double ring sensor featuring a narrow angular aperture
    • jbo JBOPFO 1083-3668 10.1117/1.1805556
    • R. G. M., Kolkman, E., Hondebrink, W., Steenbergen, T. G., van Leeuwen, and F. F. M., de Mul, " Photoacoustic imaging of blood vessels with a double ring sensor featuring a narrow angular aperture, ", J. Biomed. Opt., 9, 1327-1335 (2004). jbo JBOPFO 1083-3668 10.1117/1.1805556
    • (2004) J. Biomed. Opt. , vol.9 , pp. 1327-1335
    • Kolkman, R.G.M.1    Hondebrink, E.2    Steenbergen, W.3    Van Leeuwen, T.G.4    De Mul, F.F.M.5
  • 14
    • 0029096786 scopus 로고
    • Tissue parameters determining the visual appearance of normal skin and port-wine stains
    • cfo ZZZZZZ 0268-8921
    • L. O., Svaasand, L. T., Norvang, E. J., Fiskerstrand, E. K. S., Stopps, M. W., Berns and J. S., Nelson, " Tissue parameters determining the visual appearance of normal skin and port-wine stains, ", Lasers Med. Sci., 10, 55-65 (1995). cfo ZZZZZZ 0268-8921
    • (1995) Lasers Med. Sci. , vol.10 , pp. 55-65
    • Svaasand, L.O.1    Norvang, L.T.2    Fiskerstrand, E.J.3    Stopps, E.K.S.4    Berns, M.W.5    Nelson, J.S.6
  • 15
    • 33645238951 scopus 로고    scopus 로고
    • Polarized laser Doppler perfusion imaging - Reduction of movement-induced artifacts
    • jbo JBOPFO 1083-3668 10.1117/1.2120467
    • M. G. D., Karlsson and K., Wårdell, " Polarized laser Doppler perfusion imaging - reduction of movement-induced artifacts, ", J. Biomed. Opt., 10, 064002 (2005). jbo JBOPFO 1083-3668 10.1117/1.2120467
    • (2005) J. Biomed. Opt. , vol.10 , pp. 064002
    • Karlsson, M.G.D.1    Wårdell, K.2
  • 16
    • 34250662158 scopus 로고    scopus 로고
    • Path-length-resolved measurements of multiple scattered photons in static and dynamic turbid media using phase-modulated low-coherence interferometry
    • jbo JBOPFO 1083-3668 10.1117/1.2714795
    • B., Varghese, V., Rajan, T. G., van Leeuwen, and W., Steenbergen, " Path-length-resolved measurements of multiple scattered photons in static and dynamic turbid media using phase-modulated low-coherence interferometry, ", J. Biomed. Opt., 12, 024020-7 (2007). jbo JBOPFO 1083-3668 10.1117/1.2714795
    • (2007) J. Biomed. Opt. , vol.12 , pp. 024020-7
    • Varghese, B.1    Rajan, V.2    Van Leeuwen, T.G.3    Steenbergen, W.4
  • 17
    • 34548089255 scopus 로고    scopus 로고
    • Effect of speckles on the depth sensitivity of laser Doppler perfusion imaging
    • 8mi OPEXFF 1094-4087 10.1364/OE.15.010911
    • V., Rajan, B., Varghese, T. G., van Leeuwen, and W., Steenbergen, " Effect of speckles on the depth sensitivity of laser Doppler perfusion imaging, ", Opt. Express, 15, 10911-10919 (2007). 8mi OPEXFF 1094-4087 10.1364/OE.15.010911
    • (2007) Opt. Express , vol.15 , pp. 10911-10919
    • Rajan, V.1    Varghese, B.2    Van Leeuwen, T.G.3    Steenbergen, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.