메뉴 건너뛰기




Volumn 7261, Issue , 2009, Pages

Validation of four-dimensional ultrasound for targeting in minimally-invasive beating-heart surgery

Author keywords

Cardiac procedures; Enhanced reality; Image guided therapy; Intraoperative imaging; Ultrasound guidance; Validation evaluation; Visualization

Indexed keywords

CARDIAC PROCEDURES; ENHANCED REALITY; IMAGE-GUIDED THERAPY; INTRAOPERATIVE IMAGING; ULTRASOUND GUIDANCE; VALIDATION/EVALUATION;

EID: 67149107624     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.813705     Document Type: Conference Paper
Times cited : (7)

References (19)
  • 1
    • 40149089412 scopus 로고    scopus 로고
    • Virtual reality-enhanced ultrasound guidance: A novel technique for intracardiac interventions
    • DOI 10.1080/10929080801951160, PII 791127610, MMVR15
    • Linte, C., Moore, J., Wiles, A., Wedlake, C., and Peters, T., "Virtual reality-enhanced ultrasound guidance: A novel technique for intracardiac interventions," Comput Aid Surg 13, 82-94 (2008). (Pubitemid 351329016)
    • (2008) Computer Aided Surgery , vol.13 , Issue.2 , pp. 82-94
    • Linte, C.A.1    Moore, J.2    Wiles, A.D.3    Wedlake, C.4    Peters, T.M.5
  • 2
    • 0036449406 scopus 로고    scopus 로고
    • Accuracy evaluation of a 3D ultrasound-based neuronavigation system
    • DOI 10.1002/igs.10046
    • Lindseth, F., Lango, T., Bang, J., and Hernes, T. N., "Accuracy evaluation of a 3D ultrasound-based neuronavigation system," Comput Aid Surg 7, 197-222 (2002). (Pubitemid 35448628)
    • (2002) Computer Aided Surgery , vol.7 , Issue.4 , pp. 197-222
    • Lindseth, F.1    Lango, T.2    Bang, J.3    Hernes, T.A.N.4
  • 4
    • 67149086603 scopus 로고    scopus 로고
    • Three-dimensional ultrasound guidance and robot assistance for prostate brachytherapy
    • Peters, T. and K. Cleary, eds., Springer US
    • Wei, Z., Gardi, L., Edirisinghe, C., Downey, D., and Fenster, A., "Three-dimensional ultrasound guidance and robot assistance for prostate brachytherapy," in [Image-Guided Interventions: Technology and Applications], Peters, T. and Cleary, K., eds., 429-460, Springer US (2008).
    • (2008) Image-Guided Interventions: Technology and Applications , pp. 429-460
    • Wei, Z.1    Gardi, L.2    Edirisinghe, C.3    Downey, D.4    Fenster, A.5
  • 6
    • 34548420586 scopus 로고    scopus 로고
    • Robotic-assisted closure of atrial septal defect under real-time three-dimensional echo guide: in vitro study
    • DOI 10.1016/j.ejcts.2007.06.026, PII S1010794007005416
    • Suematsu, Y., Kiaii, B., Bainbridge, D., del Nido, P., and Novick, R., "Robotic-assisted closure of atrial septal defect under real-time three-dimensional echo guide: in vitro study," Eur J Cardio Thorac Surg 32, 573-576 (2007). (Pubitemid 47362700)
    • (2007) European Journal of Cardio-thoracic Surgery , vol.32 , Issue.4 , pp. 573-576
    • Suematsu, Y.1    Kiaii, B.2    Bainbridge, D.T.3    Del Nido, P.J.4    Novick, R.J.5
  • 8
    • 40149098518 scopus 로고    scopus 로고
    • Object identification accuracy under ultrasound enhanced virtual reality for minimally invasive cardiac surgery
    • Miga, M. and K. Cleary, eds., SPIE 2008
    • Wiles, A., Moore, J., Linte, C., Wedlake, C., Ahmad, A., and Peters, T., "Object identification accuracy under ultrasound enhanced virtual reality for minimally invasive cardiac surgery," in [Medical Imaging: Visualization, Image-Guided Procedures, and Modelling], Miga, M. and Cleary, K., eds., SPIE 2008 6918, 39180E (2008).
    • (2008) Medical Imaging: Visualization, Image-Guided Procedures, and Modelling , vol.6918
    • Wiles, A.1    Moore, J.2    Linte, C.3    Wedlake, C.4    Ahmad, A.5    Peters, T.6
  • 9
    • 84944079345 scopus 로고    scopus 로고
    • Interactive intra-operative 3D ultrasound reconstruction and visualization
    • Dohi, T. and R. Kikinis, eds., LNCS
    • Gobbi, D. and Peters, T., "Interactive intra-operative 3D ultrasound reconstruction and visualization," in [Medical Image Computing and Computer-Assisted Interventions], Dohi, T. and Kikinis, R., eds., LNCS 2489, 156-163 (2002).
    • (2002) Medical Image Computing and Computer-Assisted Interventions , vol.2489 , pp. 156-163
    • Gobbi, D.1    Peters, T.2
  • 11
    • 0035670075 scopus 로고    scopus 로고
    • Accuracy of an electromagnetic three-dimensional ultrasound system for carotid artery imaging
    • DOI 10.1016/S0301-5629(01)00447-1, PII S0301562901004471
    • Barratt, D., Davies, A., Hughes, A., Thom, S., and Humphries, K., "Accuracy of an electromagnetic threedimensional ultrasound system for carotid artery imaging," Ultrasound Med Biol 27, 1421-1425 (2001). (Pubitemid 34048355)
    • (2001) Ultrasound in Medicine and Biology , vol.27 , Issue.10 , pp. 1421-1425
    • Barratt, D.C.1    Davies, A.H.2    Hughes, A.D.3    Thom, S.A.4    Humphries, K.N.5
  • 12
    • 67149116416 scopus 로고    scopus 로고
    • An accessible, hands-on tutorial system for image-guided therapy and medical robotics using a robot and open source software
    • MICCAI 2007
    • Pace, D., Kikinis, R., and Hata, N., "An accessible, hands-on tutorial system for image-guided therapy and medical robotics using a robot and open source software," in [Workshop on Open Source and Open Data], MICCAI 2007 (2007).
    • (2007) in Workshop on Open Source and Open Data
    • Pace, D.1    Kikinis, R.2    Hata, N.3
  • 13
    • 84957066839 scopus 로고    scopus 로고
    • Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift
    • Taylor, C. and A. Colchester, eds., LNCS
    • Gobbi, D., Comeau, R., and Peters, T., "Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift," in [Medical Image Computing and Computer-Assisted Interventions], Taylor, C. and Colchester, A., eds., LNCS 1679, 920-927 (1999).
    • (1999) Medical Image Computing and Computer-Assisted Interventions , vol.1679 , pp. 920-927
    • Gobbi, D.1    Comeau, R.2    Peters, T.3
  • 14
    • 13644249539 scopus 로고    scopus 로고
    • Brain deformation correction using interactive 3D ultrasound imaging
    • The University of Western Ontario, London, Canada
    • Gobbi, D., Brain deformation correction using interactive 3D ultrasound imaging, PhD thesis, Department of Medical Biophysics, The University of Western Ontario, London, Canada (2003).
    • (2003) PhD thesis, Department of Medical Biophysics
    • Gobbi, D.1
  • 15
    • 0004038491 scopus 로고
    • Least-squares best-fit geometric elements
    • National Physical Laboratory (April
    • Forbes, A., "Least-squares best-fit geometric elements," Tech. Rep. NPL Report DITC 140/89, National Physical Laboratory (April 1989).
    • (1989) Tech. Rep. NPL Report DITC 140/89
    • Forbes, A.1
  • 16
    • 4544330160 scopus 로고    scopus 로고
    • Least squares ellipsoid specific fitting
    • IEEE Computer Society
    • Li, Q. and Griffiths, J., "Least squares ellipsoid specific fitting," in [Geometric Modeling and Processing], 335-340, IEEE Computer Society (2004).
    • (2004) Geometric Modeling and Processing , pp. 335-340
    • Li, Q.1    Griffiths, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.