메뉴 건너뛰기




Volumn 7261, Issue , 2009, Pages

In vitro cardiac catheter navigation via augmented reality surgical guidance

Author keywords

Augmented reality environments; Image guided cardiac procedures; In vitro therapy evaluation.; Intra operative visualization and navigation

Indexed keywords

BEATING HEART; CARDIAC INTERVENTIONS; CLINICAL STAFF; IMAGE-GUIDED CARDIAC PROCEDURES; IN VITRO THERAPY EVALUATION.; IN-VITRO; INTRA-OPERATIVE VISUALIZATION AND NAVIGATION; INVASIVENESS; MAGNETIC TRACKING; MULTI-MODALITY; RADIATION EXPOSURE; REAL-TIME FLUOROSCOPY; SURGICAL GUIDANCE; TARGETING ACCURACY; THERAPY DELIVERY; ULTRASOUND IMAGES;

EID: 67149098209     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.813829     Document Type: Conference Paper
Times cited : (6)

References (18)
  • 2
    • 0028269756 scopus 로고
    • Radiofrequency catheter ablation guided by intracardiac echocardiography
    • E. Chu, A. P. Fitzpatrick, M. C. Chin, K. Sudhir, P. G. Yock, and M. D. Lesh, "Radiofrequency catheter ablation guided by intracardiac eachcardiography," Circulation 89, pp. 1301-05, 1994. (Pubitemid 24076558)
    • (1994) Circulation , vol.89 , Issue.3 , pp. 1301-1305
    • Chu, E.1    Fitzpatrick, A.P.2    Chin, M.C.3    Sudhir, K.4    Yock, P.G.5    Lesh, M.D.6
  • 3
    • 0034622655 scopus 로고    scopus 로고
    • Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging
    • A. C. Lardo, E. McVeigh, P. Jumrussirikul, R. D. Berger, H. Calkins, J. Lima, and H. R. Halperin, "Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging," Circulation 102, pp. 698-705, 2000. (Pubitemid 30640672)
    • (2000) Circulation , vol.102 , Issue.6 , pp. 698-705
    • Lardo, A.C.1    McVeigh, E.R.2    Jumrussirikul, P.3    Berger, R.D.4    Calkins, H.5    Lima, J.6    Halperin, H.R.7
  • 5
    • 0033767243 scopus 로고    scopus 로고
    • Catheter navigation in modern electrophysiology
    • S. Ben-Haim, "Catheter navigation in modern electrophysiology," J Cardiovasc Electrophysiol. 11, pp. 1193- 95, 2000. (Pubitemid 30824270)
    • (2000) Journal of Cardiovascular Electrophysiology , vol.11 , Issue.11 , pp. 1193-1195
    • Ben-Haim, S.A.1
  • 6
    • 40149089412 scopus 로고    scopus 로고
    • Virtual reality-enhanced ultrasound guidance: A novel technique for intracardiac interventions
    • DOI 10.1080/10929080801951160, PII 791127610, MMVR15
    • C. A. Linte, J. Moore, A. D. Wiles, C. Wedlake, and T. M. Peters, "Virtual reality-enhanced ultrasound guidance: A novel technique for intracardiac interventions," Comput Aided Surg. 13, pp. 82-94, 2008. (Pubitemid 351329016)
    • (2008) Computer Aided Surgery , vol.13 , Issue.2 , pp. 82-94
    • Linte, C.A.1    Moore, J.2    Wiles, A.D.3    Wedlake, C.4    Peters, T.M.5
  • 8
    • 40149089412 scopus 로고    scopus 로고
    • Virtual reality-enhanced ultrasound guidance: A novel technique for intracardiac interventions
    • DOI 10.1080/10929080801951160, PII 791127610, MMVR15
    • C. A. Linte, A. Wiles, J. Moore, C. Wedlake, and T. M. Peters, "Virtual reality-enhanced ultrasound guidance for atrial ablation: In vitro epicardial study," in Lect Notes Comput Sci., 5242, pp. 644-51, 2008. (Pubitemid 351329016)
    • (2008) Computer Aided Surgery , vol.13 , Issue.2 , pp. 82-94
    • Linte, C.A.1    Moore, J.2    Wiles, A.D.3    Wedlake, C.4    Peters, T.M.5
  • 11
    • 67349214041 scopus 로고    scopus 로고
    • Inside the beating heart: An in vivo feasibility study on fusing pre- and intra-operative imaging for minimally invasive therapy
    • DOI: 10.1007/s11548-008-0278-6. In press
    • C. A. Linte, J. Moore, C. Wedlake, D. Bainbridge, G. M. Guiraudon, D. L. Jones, and T. M. Peters, "Inside the beating heart: An in vivo feasibility study on fusing pre- and intra-operative imaging for minimally invasive therapy," Int J CARS DOI: 10.1007/s11548-008-0278-6. In press, 2008.
    • (2008) Int J CARS
    • Linte, C.A.1    Moore, J.2    Wedlake, C.3    Bainbridge, D.4    Guiraudon, G.M.5    Jones, D.L.6    Peters, T.M.7
  • 13
    • 84957066839 scopus 로고    scopus 로고
    • Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift
    • D. G. Gobbi, R. M. Comeau, and T. M. Peters, "Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift," in LNCS, Proc. of Med Image Comput Comput Assist Interv. 1679, pp. 920-927, 1999.
    • (1999) LNCS, Proc. of Med Image Comput Comput Assist Interv. , vol.1679 , pp. 920-927
    • Gobbi, D.G.1    Comeau, R.M.2    Peters, T.M.3
  • 18
    • 40149095934 scopus 로고    scopus 로고
    • A statistical model for point-based target registration error with anisotropic fiducial localizer error
    • DOI 10.1109/TMI.2007.908124, 4359067
    • A. D. Wiles, A. Likholyot, D. D. Frantz, and T. M. Peters, "A statistical model for point-based target registration error with anisotropic fiducial localizer error," IEEE Trans Med Imaging 3, 2008. (Pubitemid 351324786)
    • (2008) IEEE Transactions on Medical Imaging , vol.27 , Issue.3 , pp. 378-390
    • Wiles, A.D.1    Likholyot, A.2    Frantz, D.D.3    Peters, T.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.