-
1
-
-
0030797124
-
Mistakes in a stat laboratory: Types and frequency
-
Plebani M, Carraro P. Mistakes in a stat laboratory: types and frequency. Clin Chem. 1997;43:1348-1351. (Pubitemid 27329780)
-
(1997)
Clinical Chemistry
, vol.43
, Issue.8
, pp. 1348-1351
-
-
Plebani, M.1
Carraro, P.2
-
2
-
-
0033972513
-
Hemolyzed specimens: A reason for rejection or a clinical challenge? [3]
-
Carraro P, Servidio G, Plebani M. Hemolyzed specimens: a reason for rejection or a clinical challenge? Clin Chem. 2000;46:306-307. (Pubitemid 30104266)
-
(2000)
Clinical Chemistry
, vol.46
, Issue.2
, pp. 306-307
-
-
Carraro, P.1
Servidio, G.2
Plebani, M.3
-
3
-
-
0030893027
-
Chemistry specimen acceptability: A College of American Pathologists Q- Probes study of 453 laboratories
-
Jones BA, Calam RR, Howanitz PJ. Chemistry specimen acceptability: a College of American Pathologists Q-Probes study of 453 laboratories. Arch Pathol Lab Med. 1997;121:19-26. (Pubitemid 27130661)
-
(1997)
Archives of Pathology and Laboratory Medicine
, vol.121
, Issue.1
, pp. 19-26
-
-
Jones, B.A.1
Calam, R.R.2
Howanitz, P.J.3
-
4
-
-
44949158707
-
Haemolysis: An overview of the leading cause of unsuitable specimens in clinical laboratories
-
DOI 10.1515/CCLM.2008.170
-
Lippi G, Blanckaert N, Bonini P, et al. Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories [review]. Clin Chem Lab Med. 2008;46:764-772. (Pubitemid 351821645)
-
(2008)
Clinical Chemistry and Laboratory Medicine
, vol.46
, Issue.6
, pp. 764-772
-
-
Lippi, G.1
Blanckaert, N.2
Bonini, P.3
Green, S.4
Kitchen, S.5
Palicka, V.6
Vassault, A.J.7
Plebani, M.8
-
5
-
-
14944352962
-
Poor knowledge and faulty thinking regarding hemolysis and potassium elevation
-
DOI 10.1515/CCLM.2005.037
-
Hawkins RC. Poor knowledge and faulty thinking regarding hemolysis and potassium elevation. Clin Chem Lab Med. 2005;43:216-220. (Pubitemid 40361473)
-
(2005)
Clinical Chemistry and Laboratory Medicine
, vol.43
, Issue.2
, pp. 216-220
-
-
Hawkins, R.C.1
-
6
-
-
0027171503
-
Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays
-
Jay DW, Provasek D. Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays. Clin Chem. 1993;39:1804-1810. (Pubitemid 23277008)
-
(1993)
Clinical Chemistry
, vol.39
, Issue.9
, pp. 1804-1810
-
-
Jay, D.W.1
Provasek, D.2
-
7
-
-
27744586464
-
Correction of factitious hyperkalemia in hemolyzed specimens
-
DOI 10.1016/j.ajem.2005.05.011, PII S0735675705002615
-
Owens H, Siparsky G, Bajaj L, Hampers LC. Correction of factitious hyperkalemia in hemolyzed specimens. Am J Emerg Med. 2005;23:872-875. (Pubitemid 41618017)
-
(2005)
American Journal of Emergency Medicine
, vol.23
, Issue.7
, pp. 872-875
-
-
Owens, H.1
Siparsky, G.2
Bajaj, L.3
C Hampers, L.4
-
8
-
-
17144371015
-
Correction and reporting of potassium results in haemolysed samples
-
DOI 10.1258/0004563053492739
-
Dimeski G, Clague AE, Hickman PE. Correction and reporting of potassium results in haemolysed samples. Ann Clin Biochem. 2005;42:119-123. (Pubitemid 40516142)
-
(2005)
Annals of Clinical Biochemistry
, vol.42
, Issue.2
, pp. 119-123
-
-
Dimeski, G.1
Clague, A.E.2
Hickman, P.E.3
-
9
-
-
30844447907
-
Correction and reporting of potassium results in haemolysed samples [7]
-
DOI 10.1258/000456306775141849
-
Hawkins RC. Correction and reporting of potassium results in haemolysed samples. Ann Clin Biochem. 2006;43:88-89. (Pubitemid 43105070)
-
(2006)
Annals of Clinical Biochemistry
, vol.43
, Issue.1
, pp. 88-89
-
-
Hawkins, R.C.1
-
10
-
-
0036229999
-
Variability in potassium/hemoglobin ratios for hemolysis correction [1]
-
Hawkins R. Variability in potassium/hemoglobin ratios for hemolysis correction [letter]. Clin Chem. 2002;48:796. (Pubitemid 34439122)
-
(2002)
Clinical Chemistry
, vol.48
, Issue.5
, pp. 796
-
-
Hawkins, R.1
-
11
-
-
0031032885
-
Ionic calcium content of light dense human red cells separated by Percoll density gradients
-
DOI 10.1016/S0005-2736(96)00141-1, PII S0005273696001411
-
Romero PJ, Romero EA, Winkler MD. Ionic calcium content of light dense human red cells separated by percoll density gradients. Biochim Biophys Acta. 1997;1323:23-28. (Pubitemid 27051430)
-
(1997)
Biochimica et Biophysica Acta - Biomembranes
, vol.1323
, Issue.1
, pp. 23-28
-
-
Romero, P.J.1
Romero, E.A.2
Winkler, M.D.3
-
12
-
-
0025086837
-
Setting analytical goals for random analytical error in specific clinical monitoring situations
-
Fraser CG, Hyltoft Peterson P, Larsen ML. Setting analytical goals for randon analytical error in specific clinical monitoring situations. Clin Chem. 1990;36:1625-1629. (Pubitemid 20340813)
-
(1990)
Clinical Chemistry
, vol.36
, Issue.9
, pp. 1625-1628
-
-
Fraser, C.G.1
Petersen, P.H.2
Larsen, M.L.3
-
13
-
-
67049146948
-
-
Biological Variability Data Bank. Available at: Accessed May, 2008
-
Biological Variability Data Bank. Available at: http://www.westgard.com/ biobank1.htm. Accessed May, 2008.
-
-
-
-
14
-
-
0033369894
-
Current databases on biological variation: Pros, cons and progress
-
Ricos C, Alvarez V, Cava F, et al. Current database on biological variation: pros, cons and progress. Scand J Clin Lab Invest. 1999;59:491-500. (Pubitemid 30056739)
-
(1999)
Scandinavian Journal of Clinical and Laboratory Investigation
, vol.59
, Issue.7
, pp. 491-500
-
-
Ricos, C.1
Alvarez, V.2
Cava, F.3
Garcia-Lario, J.V.4
Hernandez, A.5
Jimenez, C.V.6
Minchinela, J.7
Perich, C.8
Simon, M.9
-
15
-
-
84941843918
-
Haemolysis as an influence and interference factor in clinical chemistry
-
Guder WG. Haemolysis as an influence and interference factor in clinical chemistry. J Clin Chem Clin Biochem. 1986;24:125-126. (Pubitemid 16105579)
-
(1986)
Journal of Clinical Chemistry and Clinical Biochemistry
, vol.24
, Issue.2
, pp. 125-126
-
-
Guder, W.G.1
-
16
-
-
0027960559
-
Interference with clinical laboratory analyses
-
Kroll MH, Elin RJ. Interference with clinical laboratory analyses. Clin Chem. 1994;40:1996-2005. (Pubitemid 24346163)
-
(1994)
Clinical Chemistry
, vol.40
, Issue.11 I
, pp. 1996-2005
-
-
Kroll, M.H.1
Elin, R.J.2
-
18
-
-
0021337912
-
Drug Effects in clinical chemistry. Part II. Guidelines for evaluation of analytical interference
-
Galteau MM, Siest G. Drug effects in clinical chemistry. Part 2. Guidelines for evaluation of analytical interferences. J Clin Chem Clin Biochem. 1984;22:275-279. (Pubitemid 14166435)
-
(1984)
Journal of Clinical Chemistry and Clinical Biochemistry
, vol.22
, Issue.3
, pp. 275-279
-
-
Galteau, M.M.1
Siest, G.2
-
19
-
-
0022347366
-
Analytical interference of drugs in clinical chemistry: I - Study of twenty drugs on seven different instruments
-
DOI 10.1016/S0009-9120(85)80073-4
-
Letellier G, Desjarlais F. Analytical interference of drugs in clinical chemistry. 1. Study of twenty drugs on seven different instruments. Clin Biochem. 1985;18:345-351. (Pubitemid 16171479)
-
(1985)
Clinical Biochemistry
, vol.18
, Issue.6
, pp. 345-351
-
-
Letellier, G.1
Desjarlais, F.2
-
20
-
-
0020534949
-
The relationship between the osmotic fragility of human erythrocytes and cell age
-
Rifkind JM, Araki K, Hadley EC. The relationship between the osmotic fragility of human erythrocytes and cell age. Arch Biochem Biophys. 1983;222:582-589.
-
(1983)
Arch Biochem Biophys
, vol.222
, pp. 582-589
-
-
Rifkind, J.M.1
Araki, K.2
Hadley, E.C.3
-
21
-
-
0025213288
-
Synergistic effects of oxidation and deformation on erythrocyte monovalent cation leak
-
Ney PA, Christopher MM, Habel RP. Synergistic effects of oxidation and deformation on erythrocyte monovalent cation leak. Blood. 1990;75:1192-1198. (Pubitemid 20086829)
-
(1990)
Blood
, vol.75
, Issue.5
, pp. 1192-1198
-
-
Ney, P.A.1
Christopher, M.M.2
Hebbel, R.P.3
-
23
-
-
0015406209
-
The effect of hemolysis on the determination of plasma constituents
-
Brydon WG, Roberts LB. The effect of hemolysis on the determination of plasma constituents. Clin Chim Acta. 1972;41:435-438.
-
(1972)
Clin Chim Acta
, vol.41
, pp. 435-438
-
-
Brydon, W.G.1
Roberts, L.B.2
-
24
-
-
0022508541
-
Erythrocyte cation transport activities as a function of cell age
-
DOI 10.1016/0009-8981(86)90315-3
-
Hentschel WM, Wu LL, Tobin GO, et al. Erythrocyte cation transport activities as a function of cell age. Clin Chim Acta. 1986;157:33-43. (Pubitemid 16067715)
-
(1986)
Clinica Chimica Acta
, vol.157
, Issue.1
, pp. 33-44
-
-
Hentschel, W.M.1
Wu, L.L.2
Tobin, G.O.3
-
25
-
-
0018056528
-
Ouabain binding and potassium transport in young and old populations of human red cells
-
Joiner CH, Lauf PK. Ouabain binding and potassium transport in young and old populations of human red cells. Membr Biochem. 1978;1:187-202. (Pubitemid 10099384)
-
(1978)
Membrane Biochemistry
, vol.1
, Issue.3-4
, pp. 187-202
-
-
Joiner, C.H.1
Lauf, P.K.2
-
26
-
-
0029079767
-
Pseudohyperkalemia in extreme leukocytosis
-
Colussi G, Ciprini D. Pseudohyperkalemia in extreme leukocytosis. Am J Nephrol. 1995;15:450-452.
-
(1995)
Am J Nephrol
, vol.15
, pp. 450-452
-
-
Colussi, G.1
Ciprini, D.2
-
27
-
-
0018134656
-
Effect of in vitro hemolysis on chemical values for serum
-
Frank JJ, Bermes EW, Bickel MJ, Watkins BF. Effect of in vitro hemolysis on chemical values for serum. Clin Chem. 1978;24:1966-1970. (Pubitemid 9049071)
-
(1978)
Clinical Chemistry
, vol.24
, Issue.11
, pp. 1966-1970
-
-
Frank, J.J.1
Bermes, E.W.2
Bickel, M.J.3
Watkins, B.F.4
-
28
-
-
72849171849
-
Effects of hemolysis on serum electrolyte values
-
Mather A, Mackie NR. Effects of hemolysis on serum electrolyte values. Clin Chem. 1960;6:223-227.
-
(1960)
Clin Chem
, vol.6
, pp. 223-227
-
-
Mather, A.1
Mackie, N.R.2
-
30
-
-
33644831902
-
Influence of hemolysis on routine clinical chemistry testing
-
DOI 10.1515/CCLM.2006.054
-
Lippi G, Salvagno GL, Montagnana M, Brocco G, Guidi GC. Influence of hemolysis on routine clinical chemistry testing. Clin Chem Lab Med. 2006;44:311-316. (Pubitemid 43357691)
-
(2006)
Clinical Chemistry and Laboratory Medicine
, vol.44
, Issue.3
, pp. 311-316
-
-
Lippi, G.1
Salvagno, G.L.2
Montagnana, M.3
Brocco, G.4
Guidi, G.C.5
-
31
-
-
0025858736
-
Effects of hemolysis on chemistry tests
-
Pai SH, Cyr-Manthey M. Effects of hemolysis on chemistry tests. Lab Med. 1991;22:408-410.
-
(1991)
Lab Med
, vol.22
, pp. 408-410
-
-
Pai, S.H.1
Cyr-Manthey, M.2
-
32
-
-
33846528579
-
Correction of patient results for Beckman Coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids: A practical approach
-
DOI 10.1515/CCLM.2007.004
-
Vermeer HJ, Steen G, Naus AJM, Goevaerts B, Agricola PT, Schoenmakers CHH. Correction of patient results for Beckman Coulter LX20 assays affected by interference due to hemoglobin, bilirubin or lipids: a practical approach. Clin Chem Lab Med. 2007;45:114-119. (Pubitemid 46155573)
-
(2007)
Clinical Chemistry and Laboratory Medicine
, vol.45
, Issue.1
, pp. 114-119
-
-
Vermeer, H.J.1
Steen, G.2
Naus, A.J.M.3
Goevaerts, B.4
Agricola, P.T.5
Schoenmakers, C.H.H.6
-
33
-
-
33745210557
-
Use of haemolysis index to estimate potassium concentration in in-vitro haemolysed serum samples
-
DOI 10.1515/CCLM.2006.140
-
Shepard J, Warner MH, Poon P, Kilpatrick ES. Use of haemolysis index to estimate potassium concentration in in-vitro haemolysed serum samples. Clin Chem Lab Med. 2006;44:877-879. (Pubitemid 43911563)
-
(2006)
Clinical Chemistry and Laboratory Medicine
, vol.44
, Issue.7
, pp. 877-879
-
-
Shepherd, J.1
Warner, M.H.2
Poon, P.3
Kilpatrick, E.S.4
-
34
-
-
33645763031
-
Multicenter evaluation of the interference of hemoglobin, bilibrubin and lipids on Synchron LX-20 assays
-
Steen G, Vermeer HJ, Naus AJM, Goevaerts B, Agricola PT, Schoenmakers CHH. Multicenter evaluation of the interference of hemoglobin, bilibrubin and lipids on Synchron LX-20 assays. Clin Chem Lab Med. 2006;44:413-419.
-
(2006)
Clin Chem Lab Med
, vol.44
, pp. 413-419
-
-
Steen, G.1
Vermeer, H.J.2
Naus, A.J.M.3
Goevaerts, B.4
Agricola, P.T.5
Schoenmakers, C.H.H.6
-
35
-
-
16544363497
-
Legal dangers of testing unacceptable specimens
-
Harty-Golder B. Legal dangers of testing unacceptable specimens. Med Lab Observer. 2004;36:43.
-
(2004)
Med Lab Observer
, vol.36
, pp. 43
-
-
Harty-Golder, B.1
-
36
-
-
0036872698
-
Comparison of hemolysis in blood samples collected using an automatic incision device and a manual lance
-
Kazmierczak SC, Robertson AF, Briley KP. Comparison of hemolysis in blood samples collected using an automated incision device and a manual lance. Arch Pediatr Lab Med. 2002;156:1072-1074. (Pubitemid 36343449)
-
(2002)
Archives of Pediatrics and Adolescent Medicine
, vol.156
, Issue.11
, pp. 1072-1074
-
-
Kazmierczak, S.C.1
Robertson, A.F.2
Briley, K.P.3
|