메뉴 건너뛰기




Volumn 4791 LNCS, Issue PART 1, 2007, Pages 784-791

Boundary-specific cost functions for quantitative airway analysis

Author keywords

[No Author keywords available]

Indexed keywords

BOUNDARY CONDITIONS; COST FUNCTIONS; DYNAMIC PROGRAMMING; IMAGE ANALYSIS; PATIENT MONITORING;

EID: 66749132435     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-540-75757-3_95     Document Type: Conference Paper
Times cited : (18)

References (18)
  • 1
    • 33645205263 scopus 로고    scopus 로고
    • Serial Change in Airway Lumen and Wall Thickness at Thin-Section CT in Asymptomatic Subjects
    • December
    • Matsuoka, S., Kurihara, Y., Nakajima, Y., Niimi, H., Ashida, H., Kaneoya, K.: Serial Change in Airway Lumen and Wall Thickness at Thin-Section CT in Asymptomatic Subjects. Radiology (December 2004)
    • (2004) Radiology
    • Matsuoka, S.1    Kurihara, Y.2    Nakajima, Y.3    Niimi, H.4    Ashida, H.5    Kaneoya, K.6
  • 2
    • 0029404688 scopus 로고
    • Statistical Models of Partial Volume Effect
    • November
    • Santago, P., Gage, H.D.: Statistical Models of Partial Volume Effect. IEEE Trans. Img. Proc. pp. 1531-1540 (November 1995)
    • (1995) IEEE Trans. Img. Proc , pp. 1531-1540
    • Santago, P.1    Gage, H.D.2
  • 6
    • 0041421080 scopus 로고    scopus 로고
    • Maximizing quantitative accuracy of the lung airway lumen and wall measures obtained from X-ray CT imaging
    • Saba, O., Hoffmann, E.A., Reinhardt, J.M.: Maximizing quantitative accuracy of the lung airway lumen and wall measures obtained from X-ray CT imaging. J. Applied Physiology 95, 1063-1095 (2003)
    • (2003) J. Applied Physiology , vol.95 , pp. 1063-1095
    • Saba, O.1    Hoffmann, E.A.2    Reinhardt, J.M.3
  • 7
    • 84883834803 scopus 로고    scopus 로고
    • Estépar, R.S.J., Washko, G.G., Silverman, E.K., Reilly, J.J., Kikinis, R., Westin, C.F.: Accurate Airway Wall Estimation Using Phase Congruency. In: Larsen, R., Nielsen, M., Sporring, J. (eds.) MICCAI2006. LNCS, 4191, Springer, Heidelberg (2006)
    • Estépar, R.S.J., Washko, G.G., Silverman, E.K., Reilly, J.J., Kikinis, R., Westin, C.F.: Accurate Airway Wall Estimation Using Phase Congruency. In: Larsen, R., Nielsen, M., Sporring, J. (eds.) MICCAI2006. LNCS, vol. 4191, Springer, Heidelberg (2006)
  • 8
    • 0001999731 scopus 로고    scopus 로고
    • Modeling, segmentation, and caliber estimation of bronchi in high-resolution computerized tomography
    • Preteux, F., Fetita, C.I., Grenier, P., Capderou, A.: Modeling, segmentation, and caliber estimation of bronchi in high-resolution computerized tomography. J. Electron. Imag. 8(1), 36-45 (1999)
    • (1999) J. Electron. Imag , vol.8 , Issue.1 , pp. 36-45
    • Preteux, F.1    Fetita, C.I.2    Grenier, P.3    Capderou, A.4
  • 9
    • 0033624998 scopus 로고    scopus 로고
    • Automated anatomical labeling of the bronchial branch and its applications to the virtual bronchoscopy
    • Mori, K., Suenaga, Y., Toriwaki, J.: Automated anatomical labeling of the bronchial branch and its applications to the virtual bronchoscopy. Med. Imag. 19(2), 103-114 (2000)
    • (2000) Med. Imag , vol.19 , Issue.2 , pp. 103-114
    • Mori, K.1    Suenaga, Y.2    Toriwaki, J.3
  • 11
    • 29144514433 scopus 로고    scopus 로고
    • Intrathoracic Airway Trees: Segmentation and Airway Morphology Analysis From Low-Dose CT Scans
    • Tschirren, J., Hoffman, E.A., McLennan, G., Sonka, M.: Intrathoracic Airway Trees: Segmentation and Airway Morphology Analysis From Low-Dose CT Scans. IEEE Trans. Med. Imag. 24(12) (2005)
    • (2005) IEEE Trans. Med. Imag , vol.24 , Issue.12
    • Tschirren, J.1    Hoffman, E.A.2    McLennan, G.3    Sonka, M.4
  • 12
    • 33745363987 scopus 로고    scopus 로고
    • Automated airway evaluation system for multi-slice computed tomography using airway lumen diameter, airway wall thickness and broncho-arterial ratio
    • Odry, B.L., Kiraly, A.P., Novak, C.L., et al.: Automated airway evaluation system for multi-slice computed tomography using airway lumen diameter, airway wall thickness and broncho-arterial ratio. In: Proc. SPIE Medical Imaging 2006, vol. 6143 (2006)
    • (2006) Proc. SPIE Medical Imaging , vol.6143
    • Odry, B.L.1    Kiraly, A.P.2    Novak, C.L.3
  • 13
    • 85120229474 scopus 로고    scopus 로고
    • Wiemker, R., Blaffert, T., Bülow, T., Renisch, S., Lorenz, C.: Automated assessment of bronchial lumen, wall thickness and bronchoarterial diameter ratio of the tracheobronchial tree using high-resolution CT. I.C.S. 1268 CARS (2004), pp. 973-977 (2004)
    • Wiemker, R., Blaffert, T., Bülow, T., Renisch, S., Lorenz, C.: Automated assessment of bronchial lumen, wall thickness and bronchoarterial diameter ratio of the tracheobronchial tree using high-resolution CT. I.C.S. 1268 CARS (2004), pp. 973-977 (2004)
  • 16
    • 0031060806 scopus 로고    scopus 로고
    • Adaptive Approach to Accurate Analysis of Small-Diameter Vessels in Cineangiograms
    • Sonka, M., Reddy, G.K., Winniford, M.D., Collins, S.M.: Adaptive Approach to Accurate Analysis of Small-Diameter Vessels in Cineangiograms. IEEE Trans. Med. Imag. 16(1) (1997)
    • (1997) IEEE Trans. Med. Imag , vol.16 , Issue.1
    • Sonka, M.1    Reddy, G.K.2    Winniford, M.D.3    Collins, S.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.