메뉴 건너뛰기




Volumn 95, Issue 3, 2003, Pages 1063-1075

Maximizing quantitative accuracy of lung airway lumen and wall measures obtained from X-ray CT imaging

Author keywords

Airway area; Bronchial tree; Deconvolution; Lung imaging; Quantitative computed tomography

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; EXPERIMENTAL MODEL; LUNG FUNCTION; MATHEMATICAL MODEL; MEASUREMENT; PRIORITY JOURNAL; QUANTITATIVE DIAGNOSIS; RESPIRATORY AIRFLOW; THICKNESS; THREE DIMENSIONAL IMAGING;

EID: 0041421080     PISSN: 87507587     EISSN: None     Source Type: Journal    
DOI: 10.1152/japplphysiol.00962.2002     Document Type: Article
Times cited : (114)

References (37)
  • 1
    • 0027441143 scopus 로고
    • Assessment of methacholine-induced airway constriction by ultrafast high-resolution computed tomography
    • Amirav I, Kramer SS, Grunstein MM, and Hoffman EA. Assessment of methacholine-induced airway constriction by ultrafast high-resolution computed tomography. J Appl Physiol 75: 2239-2250, 1993.
    • (1993) J Appl Physiol , vol.75 , pp. 2239-2250
    • Amirav, I.1    Kramer, S.S.2    Grunstein, M.M.3    Hoffman, E.A.4
  • 2
    • 0031949780 scopus 로고    scopus 로고
    • Airway wall thickness in patients with near fatal asthma and control groups: Assessment with high resolution computed tomographic scanning
    • Awadh N, Muller NL, Park CS, Abboud RT, and Fitzgerald JM. Airway wall thickness in patients with near fatal asthma and control groups: assessment with high resolution computed tomographic scanning. Thorax 53: 248-253, 1998.
    • (1998) Thorax , vol.53 , pp. 248-253
    • Awadh, N.1    Muller, N.L.2    Park, C.S.3    Abboud, R.T.4    Fitzgerald, J.M.5
  • 3
    • 0021259864 scopus 로고
    • Quantitative analysis of a vascular tree model with the dynamic spatial reconstructor
    • Block M, Liu YH, Harris D, Robb RA, and Ritman EL. Quantitative analysis of a vascular tree model with the dynamic spatial reconstructor. J Comput Assist Tomogr 8: 390-400, 1984.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 390-400
    • Block, M.1    Liu, Y.H.2    Harris, D.3    Robb, R.A.4    Ritman, E.L.5
  • 5
    • 0031792957 scopus 로고    scopus 로고
    • The myth of maximal airway responsiveness in vivo
    • Brown RH and Mitzner W. The myth of maximal airway responsiveness in vivo. J Appl Physiol 85: 2012-2017, 1998.
    • (1998) J Appl Physiol , vol.85 , pp. 2012-2017
    • Brown, R.H.1    Mitzner, W.2
  • 6
    • 0028937787 scopus 로고
    • Variability in the size of individual airways over the course of one year
    • Brown RH, Zerhouni EA, and Mitzner W. Variability in the size of individual airways over the course of one year. Am J Respir Crit Care Med 151: 1159-1164, 1995.
    • (1995) Am J Respir Crit Care Med , vol.151 , pp. 1159-1164
    • Brown, R.H.1    Zerhouni, E.A.2    Mitzner, W.3
  • 7
    • 0035437719 scopus 로고    scopus 로고
    • ERS transform for the automated detection of bronchial abnormalities on CT of the lungs
    • Chabat F, Hu XP, Hansell DM, and Yang GZ. ERS transform for the automated detection of bronchial abnormalities on CT of the lungs. IEEE Trans Med Imaging 20: 942-952, 2001.
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 942-952
    • Chabat, F.1    Hu, X.P.2    Hansell, D.M.3    Yang, G.Z.4
  • 8
    • 0023235467 scopus 로고
    • Slice characteristics of the Imatron Cine-CT scanner
    • Chang W. Slice characteristics of the Imatron Cine-CT scanner. J Comput Assist Tomogr 11: 554-557, 1987.
    • (1987) J Comput Assist Tomogr , vol.11 , pp. 554-557
    • Chang, W.1
  • 11
    • 0031105134 scopus 로고    scopus 로고
    • Distributed system for processing 3D medical images
    • Higgins WE and Swift RD. Distributed system for processing 3D medical images. Comput Biol Med 27: 97-115, 1997.
    • (1997) Comput Biol Med , vol.27 , pp. 97-115
    • Higgins, W.E.1    Swift, R.D.2
  • 12
    • 0017075511 scopus 로고
    • Diameter, length and branching ratios in the bronchial tree
    • Horsfield K, Relea FG, and Cumming G. Diameter, length and branching ratios in the bronchial tree. Respir Physiol 26: 351-356, 1976.
    • (1976) Respir Physiol , vol.26 , pp. 351-356
    • Horsfield, K.1    Relea, F.G.2    Cumming, G.3
  • 13
    • 0343851691 scopus 로고    scopus 로고
    • An analysis algorithm for measuring airway lumen and wall areas from high-resolution computed tomographic data
    • King GG, Muller NL, Whittall KP, Xiang QS, and Pare PD. An analysis algorithm for measuring airway lumen and wall areas from high-resolution computed tomographic data. Am J Respir Crit Care Med 161: 574-580, 2000.
    • (2000) Am J Respir Crit Care Med , vol.161 , pp. 574-580
    • King, G.G.1    Muller, N.L.2    Whittall, K.P.3    Xiang, Q.S.4    Pare, P.D.5
  • 14
    • 0026010139 scopus 로고
    • SPECT volume quantitation: Influence of spatial resolution, source size and shape, and voxel size
    • King MA, Long DT, and Brill AB. SPECT volume quantitation: influence of spatial resolution, source size and shape, and voxel size. Med Phys 18: 1016-1024, 1991.
    • (1991) Med Phys , vol.18 , pp. 1016-1024
    • King, M.A.1    Long, D.T.2    Brill, A.B.3
  • 15
    • 0036787454 scopus 로고    scopus 로고
    • Three-dimensional human airway segmentation methods for clinical virtual bronchoscopy
    • Kiraly AP, Higgins WE, McLennan G, Hoffman EA, and Reinhardt JM. Three-dimensional human airway segmentation methods for clinical virtual bronchoscopy. Acad Radiol 9: 1153-1168, 2002.
    • (2002) Acad Radiol , vol.9 , pp. 1153-1168
    • Kiraly, A.P.1    Higgins, W.E.2    McLennan, G.3    Hoffman, E.A.4    Reinhardt, J.M.5
  • 16
    • 0032795852 scopus 로고    scopus 로고
    • A three-dimensional model of the human airway tree
    • Kitaoka H, Takaki R, and Suki B. A three-dimensional model of the human airway tree. J Appl Physiol 87: 2207-2217, 1999.
    • (1999) J Appl Physiol , vol.87 , pp. 2207-2217
    • Kitaoka, H.1    Takaki, R.2    Suki, B.3
  • 18
    • 0031460244 scopus 로고    scopus 로고
    • Development and testing of image-processing methods for the quantitative assessment of airway hyperresponsiveness from high-resolution CT images
    • McNitt-Gray MF, Goldin JG, Johnson TD, Tashkin DP, and Aberle DR. Development and testing of image-processing methods for the quantitative assessment of airway hyperresponsiveness from high-resolution CT images. J Comput Assist Tomogr 21: 939-947, 1997.
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 939-947
    • McNitt-Gray, M.F.1    Goldin, J.G.2    Johnson, T.D.3    Tashkin, D.P.4    Aberle, D.R.5
  • 19
    • 0000238336 scopus 로고
    • A simplex method for function minimization
    • Nelder JA and Mead R. A simplex method for function minimization. Computer J 7: 308-313, 1965.
    • (1965) Computer J , vol.7 , pp. 308-313
    • Nelder, J.A.1    Mead, R.2
  • 20
    • 0023870198 scopus 로고
    • Measurement of the PSF for a CT scanner: Appropriate wire diameter and pixel size
    • Nickoloff EL. Measurement of the PSF for a CT scanner: appropriate wire diameter and pixel size. Phys Med Biol 33: 149-155, 1988.
    • (1988) Phys Med Biol , vol.33 , pp. 149-155
    • Nickoloff, E.L.1
  • 22
    • 0032129159 scopus 로고    scopus 로고
    • Segmentation of intrathoracic airway trees: A fuzzy logic approach
    • Park W, Hoffman EA, and Sonka M. Segmentation of intrathoracic airway trees: a fuzzy logic approach. IEEE Trans Med Imaging 17: 489-497, 1998.
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 489-497
    • Park, W.1    Hoffman, E.A.2    Sonka, M.3
  • 23
    • 0001999731 scopus 로고    scopus 로고
    • Modeling, segmentation, and caliber estimation of bronchi in high resolution computerized tomography
    • Preteux F, Fetita CI, Capderou A, and Grenier P. Modeling, segmentation, and caliber estimation of bronchi in high resolution computerized tomography. J Elec Imag 8: 36-45, 1999.
    • (1999) J Elec Imag , vol.8 , pp. 36-45
    • Preteux, F.1    Fetita, C.I.2    Capderou, A.3    Grenier, P.4
  • 27
    • 0032791501 scopus 로고    scopus 로고
    • Semi-automated tabulation of the 3D topology and morphology of branching networks using CT: Application to the airway tree
    • Sauret V, Goatman KA, Fleming JS, and Bailey AG. Semi-automated tabulation of the 3D topology and morphology of branching networks using CT: application to the airway tree. Phys Med Biol 44: 1625-1638, 1999.
    • (1999) Phys Med Biol , vol.44 , pp. 1625-1638
    • Sauret, V.1    Goatman, K.A.2    Fleming, J.S.3    Bailey, A.G.4
  • 29
    • 0028316780 scopus 로고
    • Measurement of the internal size of bronchi using high resolution computed tomography (HRCT)
    • Seneterre E, Paganin F, Bruel JM, Michel FB, and Bousqet J. Measurement of the internal size of bronchi using high resolution computed tomography (HRCT). Eur Respir J 7: 596-600, 1994.
    • (1994) Eur Respir J , vol.7 , pp. 596-600
    • Seneterre, E.1    Paganin, F.2    Bruel, J.M.3    Michel, F.B.4    Bousqet, J.5
  • 31
    • 0018974035 scopus 로고
    • Branching angles in the bronchial tree related to order of branching
    • Thurlbeck A and Horsfield K. Branching angles in the bronchial tree related to order of branching. Respir Physiol 41: 173-181, 1980.
    • (1980) Respir Physiol , vol.41 , pp. 173-181
    • Thurlbeck, A.1    Horsfield, K.2
  • 32
    • 0029380602 scopus 로고
    • Temporal bone volumetric image deblurring in spiral computed tomography scanning
    • Wang G, Skinner MW, and Vannier MW. Temporal bone volumetric image deblurring in spiral computed tomography scanning. Acad Radiol 2: 888-895, 1995.
    • (1995) Acad Radiol , vol.2 , pp. 888-895
    • Wang, G.1    Skinner, M.W.2    Vannier, M.W.3
  • 34
    • 0021145887 scopus 로고
    • CT of a bronchial phantom: Factors affecting appearance and size measurements
    • Webb WR, Gamsu G, Cann CE, and Proctor E. CT of a bronchial phantom: factors affecting appearance and size measurements. Invest Radiol 19: 394-398, 1984.
    • (1984) Invest Radiol , vol.19 , pp. 394-398
    • Webb, W.R.1    Gamsu, G.2    Cann, C.E.3    Proctor, E.4
  • 36
    • 0028941387 scopus 로고
    • A method for measurement of cross sectional area, segment length, and branching angle of airway tree structures in situ
    • Wood SA, Hoford JD, Hoffman EA, Zerhouni E, and Mitzner W. A method for measurement of cross sectional area, segment length, and branching angle of airway tree structures in situ. Comput Med Imaging Graph 19: 145-152, 1995.
    • (1995) Comput Med Imaging Graph , vol.19 , pp. 145-152
    • Wood, S.A.1    Hoford, J.D.2    Hoffman, E.A.3    Zerhouni, E.4    Mitzner, W.5
  • 37
    • 0028832614 scopus 로고
    • Measurement of three-dimensional lung tree structures by using computed tomography
    • Wood SA, Zerhouni EA, Hoford JD, Hoffman EA, and Mitzner W. Measurement of three-dimensional lung tree structures by using computed tomography. J Appl Physiol 79: 1687-1697, 1995.
    • (1995) J Appl Physiol , vol.79 , pp. 1687-1697
    • Wood, S.A.1    Zerhouni, E.A.2    Hoford, J.D.3    Hoffman, E.A.4    Mitzner, W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.