Volumn 36, Issue 6, 2009, Pages 2069-2073

Investigation of intracranial peripheral dose arising from the treatment of large lesions with Leksell GammaKnife Perfexion

Author keywords

Dosimetry; Gafchromic film; Gamma knife; Perfexion; Stereotactic

Indexed keywords

DOSIMETRY; IRRADIATION;

EID: 66449109970     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3125133     Document Type: Article
Times cited : (4)

References (9)
  • 1
    • 34548665085 scopus 로고    scopus 로고
    • The Leksell gamma knife Perfexion and comparisons with its predecessors
    • 0148-396X,. 10.1227/01.neu.0000289726.35330.8a
    • C. Lindquist and I. Paddick, " The Leksell gamma knife Perfexion and comparisons with its predecessors.," Neurosurgery 0148-396X 61, 130-141 (2007). 10.1227/01.neu.0000289726.35330.8a
    • (2007) Neurosurgery , vol.61 , pp. 130-141
    • Lindquist, C.1    Paddick, I.2
  • 3
    • 13744263239 scopus 로고    scopus 로고
    • Computational model for the estimation of the extracranial doses received during Leksell gamma knife model C treatment
    • M. Majali, J. Novotny, and J. Novotny, Jr., " Computational model for the estimation of the extracranial doses received during Leksell gamma knife model C treatment.," J. Neurosurg. 0022-3085 102, 14-18 (2005). (Pubitemid 44783917)
    • (2005) Journal of Neurosurgery , vol.102 , Issue.SUPPL. , pp. 14-18
    • Majali, M.1    Novotny, J.2    Novotny Jr., J.3
  • 4
    • 12644295076 scopus 로고    scopus 로고
    • Transportation dose and doses to extracranial sites during stereotactic radiosurgery with Leksell gamma knife
    • 1011-6125,. 10.1159/000099686
    • J. Novotny, Jr., J. Novotny, L. Hobzova, G. Simonova, R. Liscak, and V. Vladyka, " Transportation dose and doses to extracranial sites during stereotactic radiosurgery with Leksell gamma knife.," Stereotact. Funct. Neurosurg. 1011-6125 66, 170-183 (1996). 10.1159/000099686
    • (1996) Stereotact. Funct. Neurosurg. , vol.66 , pp. 170-183
    • Novotny Jr., J.1    Novotny, J.2    Hobzova, L.3    Simonova, G.4    Liscak, R.5    Vladyka, V.6
  • 5
    • 61449145512 scopus 로고    scopus 로고
    • Radiosurgery with the world's first fully robotized Leksell Gamma Knife PerfeXion in clinical use: A 200-patient prospective, randomized, controlled comparison with the Gamma Knife 4C
    • 0148-396X,. 10.1227/01.NEU.0000337578.00814.75
    • J. Regis, M. Tamura, C. Guillot, S. Yomo, X. Muraciolle, M. Nagaje, Y. Arka, and D. Porcheron, " Radiosurgery with the world's first fully robotized Leksell Gamma Knife PerfeXion in clinical use: A 200-patient prospective, randomized, controlled comparison with the Gamma Knife 4C.," Neurosurgery 0148-396X 64, 346-355 (2009). 10.1227/01.NEU.0000337578.00814.75
    • (2009) Neurosurgery , vol.64 , pp. 346-355
    • Regis, J.1    Tamura, M.2    Guillot, C.3    Yomo, S.4    Muraciolle, X.5    Nagaje, M.6    Arka, Y.7    Porcheron, D.8
  • 6
    • 17144451998 scopus 로고    scopus 로고
    • Volumetric and dosimetric evaluation of radiation treatment plans: Radiation conformity index
    • 0360-3016,. 10.1016/S0360-3016(98)00239-9
    • T. Knoos, I. Kristensen, and P. Nilsson, " Volumetric and dosimetric evaluation of radiation treatment plans: radiation conformity index.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 42, 1169-1176 (1998). 10.1016/S0360-3016(98)00239-9
    • (1998) Int. J. Radiat. Oncol., Biol., Phys. , vol.42 , pp. 1169-1176
    • Knoos, T.1    Kristensen, I.2    Nilsson, P.3
  • 7
    • 0034433104 scopus 로고    scopus 로고
    • A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note
    • I. Paddick, " A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note.," J. Neurosurg. 0022-3085 93, 219-222 (2000). (Pubitemid 32799579)
    • (2000) Journal of Neurosurgery , vol.93 , Issue.SUPPL. 3 , pp. 219-222
    • Paddick, I.1
  • 8
    • 0342617576 scopus 로고    scopus 로고
    • A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate
    • 0360-3016,. 10.1016/S0360-3016(96)00601-3
    • A. van't Riet, A. C. Mak, M. A. Moerland, L. H. Elders, and W. van der Zee, " A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 37, 731-736 (1997). 10.1016/S0360-3016(96)00601-3
    • (1997) Int. J. Radiat. Oncol., Biol., Phys. , vol.37 , pp. 731-736
    • Van'T Riet, A.1    Mak, A.C.2    Moerland, M.A.3    Elders, L.H.4    Van Der Zee, W.5
  • 9
    • 22544440841 scopus 로고    scopus 로고
    • Precise radiochromic film dosimetry using a flat-bed document scanner
    • 0094-2405,. 10.1118/1.1929253
    • S. Devic, J. Seuntjens, E. Sham, E. B. Podgorsak, C. R. Schmidtlein, A. S. Kirov, and C. G. Soares, " Precise radiochromic film dosimetry using a flat-bed document scanner.," Med. Phys. 0094-2405 32, 2245-2253 (2005). 10.1118/1.1929253
    • (2005) Med. Phys. , vol.32 , pp. 2245-2253
    • Devic, S.1    Seuntjens, J.2    Sham, E.3    Podgorsak, E.B.4    Schmidtlein, C.R.5    Kirov, A.S.6    Soares, C.G.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.