메뉴 건너뛰기




Volumn 64, Issue 2, 2009, Pages 346-355

Radiosurgery with the world's first fully robotized leksell gamma knife perfeXion in clinical use: A 200-patient prospective, randomized, controlled comparison with the gamma knife 4C

Author keywords

Arteriovenous malformation; Radiosurgery; Robotization; Stereotactic radiotherapy; Vestibular schwannomas

Indexed keywords

ACOUSTIC NEURINOMA; ADENOMA; ADULT; ALGORITHM; ARTERIOVENOUS MALFORMATION; ARTICLE; CLINICAL TRIAL; COLLIMATOR; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DOSIMETRY; EVALUATION; FRANCE; GAMMA KNIFE RADIOSURGERY; HEAD AND NECK SURGERY; HUMAN; MAJOR CLINICAL STUDY; MEDICAL TECHNOLOGY; MENINGIOMA; METASTASIS; OPERATION DURATION; OUTCOME ASSESSMENT; PARAMETER; PATIENT SATISFACTION; PRIORITY JOURNAL; PROSPECTIVE STUDY; QUALITY CONTROL; RADIATION EXPOSURE; RANDOMIZED CONTROLLED TRIAL; ROBOTICS; SURGICAL TECHNIQUE;

EID: 61449145512     PISSN: 0148396X     EISSN: None     Source Type: Journal    
DOI: 10.1227/01.NEU.0000337578.00814.75     Document Type: Article
Times cited : (77)

References (14)
  • 3
    • 76949138594 scopus 로고
    • The stereotaxic method and radiosurgery of the brain
    • Leksell L: The stereotaxic method and radiosurgery of the brain. Acta Chir Scand 102:316-319, 1951.
    • (1951) Acta Chir Scand , vol.102 , pp. 316-319
    • Leksell, L.1
  • 5
    • 34548665085 scopus 로고    scopus 로고
    • The Leksell Gamma Knife PerfeXion and comparisons with its predecessors
    • Lindquist C, Paddick I: The Leksell Gamma Knife PerfeXion and comparisons with its predecessors. Neurosurgery 61:130-141, 2007.
    • (2007) Neurosurgery , vol.61 , pp. 130-141
    • Lindquist, C.1    Paddick, I.2
  • 6
    • 0024492354 scopus 로고
    • Stereotactic radiosurgery of the brain using the first United States 201 cobalt-60 source gamma knife
    • Lunsford LD, Flickinger JC, Lidner G, Maitz A: Stereotactic radiosurgery of the brain using the first United States 201 cobalt-60 source gamma knife. Neurosurgery 24:151-159, 1989.
    • (1989) Neurosurgery , vol.24 , pp. 151-159
    • Lunsford, L.D.1    Flickinger, J.C.2    Lidner, G.3    Maitz, A.4
  • 7
    • 85024988107 scopus 로고    scopus 로고
    • An investigation of eye lens dose for gamma knife treatments of trigeminal neuralgia
    • Ma L, Chin L, Sarfaraz M, Shepard D, Yu C: An investigation of eye lens dose for gamma knife treatments of trigeminal neuralgia. J Appl Clin Med Phys 1:116-119, 2000.
    • (2000) J Appl Clin Med Phys , vol.1 , pp. 116-119
    • Ma, L.1    Chin, L.2    Sarfaraz, M.3    Shepard, D.4    Yu, C.5
  • 8
    • 0031692285 scopus 로고    scopus 로고
    • Treatment planning of stereotactic convergent gamma-ray irradiation using Co-60 sources
    • Maitz AH, Wu A: Treatment planning of stereotactic convergent gamma-ray irradiation using Co-60 sources. Med Dosim 23:169-175, 1998.
    • (1998) Med Dosim , vol.23 , pp. 169-175
    • Maitz, A.H.1    Wu, A.2
  • 10
  • 11
    • 3042651958 scopus 로고    scopus 로고
    • Functional outcomes of radiosurgical treatment of vestibular schwannomas: 1000 successive cases and review of the literature
    • in French
    • Régis J, Delsanti C, Roche PH, Thomassin JM, Pellet W: Functional outcomes of radiosurgical treatment of vestibular schwannomas: 1000 successive cases and review of the literature [in French]. Neurochirurgie 50:301-311, 2004.
    • (2004) Neurochirurgie , vol.50 , pp. 301-311
    • Régis, J.1    Delsanti, C.2    Roche, P.H.3    Thomassin, J.M.4    Pellet, W.5
  • 12
    • 0036894787 scopus 로고    scopus 로고
    • Impact of the model C and Automatic Positioning System on gamma knife radiosurgery: An evaluation in vestibular schwannomas
    • Régis J, Hayashi M, Porcheron D, Delsanti C, Muracciole X, Peragut JC: Impact of the model C and Automatic Positioning System on gamma knife radiosurgery: An evaluation in vestibular schwannomas. J Neurosurg 97:588-591, 2002.
    • (2002) J Neurosurg , vol.97 , pp. 588-591
    • Régis, J.1    Hayashi, M.2    Porcheron, D.3    Delsanti, C.4    Muracciole, X.5    Peragut, J.C.6
  • 14
    • 0030870347 scopus 로고    scopus 로고
    • Extracranial radiation doses in patients undergoing gamma knife radiosurgery
    • Yu C, Luxton G, Apuzzo ML, MacPherson DM, Petrovich Z: Extracranial radiation doses in patients undergoing gamma knife radiosurgery. Neurosurgery 41:553-560, 1997.
    • (1997) Neurosurgery , vol.41 , pp. 553-560
    • Yu, C.1    Luxton, G.2    Apuzzo, M.L.3    MacPherson, D.M.4    Petrovich, Z.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.