메뉴 건너뛰기




Volumn 46, Issue 3, 2009, Pages 253-256

New onset of heterophilic antibody interference in prostate-specific antigen measurement occurring during the period of post-prostatectomy prostate-specific antigen monitoring

Author keywords

[No Author keywords available]

Indexed keywords

ACETYLSALICYLIC ACID; BICALUTAMIDE; CAPROMAB PENDETIDE IN 111; DEXAMETHASONE; DOCETAXEL; FAMCICLOVIR; GENTAMICIN; GOSERELIN; HETEROPHILE ANTIBODY; LORATADINE; LORAZEPAM; ONDANSETRON; PREDNISONE; PROCHLORPERAZINE; PROSTATE SPECIFIC ANTIGEN; PSEUDOEPHEDRINE;

EID: 66249131620     PISSN: 00045632     EISSN: 00045632     Source Type: Journal    
DOI: 10.1258/acb.2009.008159     Document Type: Article
Times cited : (12)

References (26)
  • 1
    • 0023853204 scopus 로고
    • Heterophilic antibodies: A problem for all immunoassays
    • Boscato LM, Stuart MC. Heterophilic antibodies: a problem for all immunoassays. Clin Chem 1988;34:27-33
    • (1988) Clin Chem , vol.34 , pp. 27-33
    • Boscato, L.M.1    Stuart, M.C.2
  • 2
    • 84944438605 scopus 로고
    • Antibodies as a source of analytical errors
    • Kohse KP, Wisser H. Antibodies as a source of analytical errors. J Clin Chem Clin Biochem 1990;28:881-892
    • (1990) J Clin Chem Clin Biochem , vol.28 , pp. 881-892
    • Kohse, K.P.1    Wisser, H.2
  • 3
    • 0032814344 scopus 로고    scopus 로고
    • Human anti-animal antibody interferences in immunological assays
    • Kricka LJ. Human anti-animal antibody interferences in immunological assays. Clin Chem 1999;45:942-956
    • (1999) Clin Chem , vol.45 , pp. 942-956
    • Kricka, L.J.1
  • 4
    • 0033885801 scopus 로고    scopus 로고
    • Interferences in immunoassay-still a threat
    • Kricka LJ. Interferences in immunoassay-still a threat. Clin Chem 2000;46:1037-1038
    • (2000) Clin Chem , vol.46 , pp. 1037-1038
    • Kricka, L.J.1
  • 5
    • 11144302516 scopus 로고    scopus 로고
    • The war on heterophilic antibody interference
    • Bjerner J, Bormer OP, Nustad K. The war on heterophilic antibody interference. Clin Chem 2005;51:9-11
    • (2005) Clin Chem , vol.51 , pp. 9-11
    • Bjerner, J.1    Bormer, O.P.2    Nustad, K.3
  • 6
    • 0036307947 scopus 로고    scopus 로고
    • Interference in immunoassay is an underestimated problem
    • Ismail AA, Walker PL, Cawood ML, et al. Interference in immunoassay is an underestimated problem. Ann Clin Biochem 2002;39:366-373
    • (2002) Ann Clin Biochem , vol.39 , pp. 366-373
    • Ismail, A.A.1    Walker, P.L.2    Cawood, M.L.3
  • 7
    • 11144252247 scopus 로고    scopus 로고
    • A radical approach is need to eliminate interference from endogenous antibodies in immunoassays
    • Ismail AA. A radical approach is need to eliminate interference from endogenous antibodies in immunoassays. Clin Chem 2005;51:25-26
    • (2005) Clin Chem , vol.51 , pp. 25-26
    • Ismail, A.A.1
  • 8
    • 34548179097 scopus 로고    scopus 로고
    • Erroneous laboratory results: What clinicians need to know
    • Ismail Y, Ismail AA, Ismail AA. Erroneous laboratory results: what clinicians need to know. Clin Med 2007;7:357-361
    • (2007) Clin Med , vol.7 , pp. 357-361
    • Ismail, Y.1    Ismail, A.A.2    Ismail, A.A.3
  • 9
    • 47549098278 scopus 로고    scopus 로고
    • Clinical case studies: Commentary
    • Kricka LJ. Clinical case studies: commentary. Clin Chem 2008;54:1245
    • (2008) Clin Chem , vol.54 , pp. 1245
    • Kricka, L.J.1
  • 10
    • 0036191429 scopus 로고    scopus 로고
    • Falsely increased prostate-specific antigen concentration attributed to heterophilic antibodies
    • Camacho T, Mora J, Segura A, et al. Falsely increased prostate-specific antigen concentration attributed to heterophilic antibodies. Ann Clin Biochem 2002;39:160-161
    • (2002) Ann Clin Biochem , vol.39 , pp. 160-161
    • Camacho, T.1    Mora, J.2    Segura, A.3
  • 11
    • 0035165378 scopus 로고    scopus 로고
    • Serum heterophile antibodies interfere with prostate specific antigen test and result in over treatment in a patient with prostate cancer
    • Morgan BR, Tarter TH. Serum heterophile antibodies interfere with prostate specific antigen test and result in over treatment in a patient with prostate cancer. J Urol 2001;166:2311-2312
    • (2001) J Urol , vol.166 , pp. 2311-2312
    • Morgan, B.R.1    Tarter, T.H.2
  • 12
    • 0036551165 scopus 로고    scopus 로고
    • Incorrect biochemistry complicates prostate cancer management
    • McAuley I, Steinhoff G, McNeely M, et al. Incorrect biochemistry complicates prostate cancer management. Can J Urol 2002;9:1496-1497
    • (2002) Can J Urol , vol.9 , pp. 1496-1497
    • McAuley, I.1    Steinhoff, G.2    McNeely, M.3
  • 13
    • 34548850935 scopus 로고    scopus 로고
    • False elevations in prostate-specific antigen levels affecting patient management
    • Kummar S, Shafi NQ. False elevations in prostate-specific antigen levels affecting patient management. Clin Adv Hematol Oncol 2004;2:599-601
    • (2004) Clin Adv Hematol Oncol , vol.2 , pp. 599-601
    • Kummar, S.1    Shafi, N.Q.2
  • 14
    • 33947274012 scopus 로고    scopus 로고
    • Spurious prostate-specific antigen (PSA) recurrence after radical prostatectomy: Interference by human antimouse heterophile antibodies
    • Park S, Wians FH Jr, Cadeddu JA. Spurious prostate-specific antigen (PSA) recurrence after radical prostatectomy: interference by human antimouse heterophile antibodies. Int J Urol 2007;14:251-253
    • (2007) Int J Urol , vol.14 , pp. 251-253
    • Park, S.1    Wians Jr., F.H.2    Cadeddu, J.A.3
  • 15
    • 24144493035 scopus 로고    scopus 로고
    • The 2005 International Society of Urological Pathology (ISUP) Consensus Conference on Gleason grading of prostatic carcinoma
    • Epstein JI, Allsbrook WC Jr, Amin MB, et al. The 2005 International Society of Urological Pathology (ISUP) Consensus Conference on Gleason grading of prostatic carcinoma. Am J Surg Pathol 2005;29:1228-1242
    • (2005) Am J Surg Pathol , vol.29 , pp. 1228-1242
    • Epstein, J.I.1    Allsbrook Jr., W.C.2    Amin, M.B.3
  • 16
    • 46449138576 scopus 로고    scopus 로고
    • The impact of the 2005 international society of urological pathology consensus conference on standard Gleason grading of prostatic carcinoma in needle biopsies
    • discussion 52-3
    • Billis A, Guimaraes MS, Freitas LL, et al. The impact of the 2005 international society of urological pathology consensus conference on standard Gleason grading of prostatic carcinoma in needle biopsies. J Urol 2008;180:548-552 (discussion 52-3)
    • (2008) J Urol , vol.180 , pp. 548-552
    • Billis, A.1    Guimaraes, M.S.2    Freitas, L.L.3
  • 17
  • 18
    • 55049102336 scopus 로고    scopus 로고
    • Interferences in immunoassays: Mechanisms and outcomes in endocrinology
    • Sapin R. Interferences in immunoassays: mechanisms and outcomes in endocrinology. Ann Endocrinol (Paris) 2008;69:415-425
    • (2008) Ann Endocrinol (Paris) , vol.69 , pp. 415-425
    • Sapin, R.1
  • 19
    • 34447283257 scopus 로고    scopus 로고
    • On detecting interference from endogenous antibodies in immunoassays by doubling dilutions test
    • Ismail AA. On detecting interference from endogenous antibodies in immunoassays by doubling dilutions test. Clin Chem Lab Med 2007;45:851-854
    • (2007) Clin Chem Lab Med , vol.45 , pp. 851-854
    • Ismail, A.A.1
  • 20
    • 0024989647 scopus 로고
    • Endogenous interference in immunoassays in clinical chemistry. A review
    • Weber TH, Kapyaho KI, Tanner P. Endogenous interference in immunoassays in clinical chemistry. A review. Scand J Clin Lab Invest Suppl 1990;201:77-82
    • (1990) Scand J Clin Lab Invest Suppl , vol.201 , pp. 77-82
    • Weber, T.H.1    Kapyaho, K.I.2    Tanner, P.3
  • 21
    • 0026560242 scopus 로고
    • Antibody multispecificity in immunoassay interference
    • Levinson SS. Antibody multispecificity in immunoassay interference. Clin Biochem 1992;25:77-87
    • (1992) Clin Biochem , vol.25 , pp. 77-87
    • Levinson, S.S.1
  • 22
    • 0032895981 scopus 로고    scopus 로고
    • When is a heterophile antibody not a heterophile antibody? When it is an antibody against a specific immunogen
    • Kaplan IV, Levinson SS. When is a heterophile antibody not a heterophile antibody? When it is an antibody against a specific immunogen. Clin Chem 1999;45:616-618
    • (1999) Clin Chem , vol.45 , pp. 616-618
    • Kaplan, I.V.1    Levinson, S.S.2
  • 23
    • 0036844469 scopus 로고    scopus 로고
    • Towards a better understanding of heterophile (and the like) antibody interference with modern immunoassays
    • Levinson SS, Miller JJ. Towards a better understanding of heterophile (and the like) antibody interference with modern immunoassays. Clin Chim Acta 2002;325:1-15
    • (2002) Clin Chim Acta , vol.325 , pp. 1-15
    • Levinson, S.S.1    Miller, J.J.2
  • 24
    • 0033869592 scopus 로고    scopus 로고
    • An IgM lambda antibody to Escherichia coli produces false-positive results in multiple immunometric assays
    • Covinsky M, Laterza O, Pfeifer JD, et al. An IgM lambda antibody to Escherichia coli produces false-positive results in multiple immunometric assays. Clin Chem 2000;46:1157-1161
    • (2000) Clin Chem , vol.46 , pp. 1157-1161
    • Covinsky, M.1    Laterza, O.2    Pfeifer, J.D.3
  • 26
    • 0030985128 scopus 로고    scopus 로고
    • Biological variation of prostate specific antigen levels in serum: An evaluation of day-to-day physiological fluctuations in a well-defined cohort of 24 patients
    • Nixon RG, Wener MH, Smith KM, et al. Biological variation of prostate specific antigen levels in serum: an evaluation of day-to-day physiological fluctuations in a well-defined cohort of 24 patients. J Urol 1997;157:2183-2190
    • (1997) J Urol , vol.157 , pp. 2183-2190
    • Nixon, R.G.1    Wener, M.H.2    Smith, K.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.