메뉴 건너뛰기




Volumn 67, Issue 7-8, 2009, Pages 1421-1425

Development of a new design 125I-brachytherapy seed for its application in the treatment of eye and prostate cancer

Author keywords

125I; Adsorption; Dose rate constant; Leachability; Ocular brachytherapy

Indexed keywords

125I; BRACHYTHERAPY; DOSE RATE CONSTANT; DOSE RATE CONSTANTS; EXPERIMENTAL CONDITIONS; LEACHABILITY; ND : YAG LASERS; NEW DESIGN; NEW SOURCES; OCULAR BRACHYTHERAPY; PROSTATE CANCERS;

EID: 66149101340     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2009.02.040     Document Type: Article
Times cited : (19)

References (16)
  • 1
    • 66149152090 scopus 로고    scopus 로고
    • AERB SS-3 (Rev-1), 2001. Testing and Classification of Sealed Radioactive Sources. A Publication of Atomic Energy Regulatory Board of India.
    • AERB SS-3 (Rev-1), 2001. Testing and Classification of Sealed Radioactive Sources. A Publication of Atomic Energy Regulatory Board of India.
  • 4
    • 26844533463 scopus 로고    scopus 로고
    • Prostate brachytherapy: a review of current practice
    • Bownes P., and Flynn A. Prostate brachytherapy: a review of current practice. J. Radiotherapy Practice 4 (2004) 86-101
    • (2004) J. Radiotherapy Practice , vol.4 , pp. 86-101
    • Bownes, P.1    Flynn, A.2
  • 5
    • 0035051575 scopus 로고    scopus 로고
    • Comparison of I-125 sources used for permanent interstitial implants
    • Bret H.H., Robert E.W., and James M.H. Comparison of I-125 sources used for permanent interstitial implants. Med. Phys. 28 (2001) 671-682
    • (2001) Med. Phys. , vol.28 , pp. 671-682
    • Bret, H.H.1    Robert, E.W.2    James, M.H.3
  • 6
    • 0030723711 scopus 로고    scopus 로고
    • Radiation therapy for choroidal melanoma
    • Finger P.T. Radiation therapy for choroidal melanoma. Surv. Opthalmol. 42 (1997) 215-232
    • (1997) Surv. Opthalmol. , vol.42 , pp. 215-232
    • Finger, P.T.1
  • 8
    • 34247240522 scopus 로고    scopus 로고
    • Dosimetric and technical aspects of intraoperative I-125 brachytherapy for stage I non-small cell lung cancer
    • Johnson M., Colonias A., Parda D., Trombetta M., Gayou O., Reitz B., and Miften M. Dosimetric and technical aspects of intraoperative I-125 brachytherapy for stage I non-small cell lung cancer. Phys. Med. Biol. 52 (2007) 1237-1245
    • (2007) Phys. Med. Biol. , vol.52 , pp. 1237-1245
    • Johnson, M.1    Colonias, A.2    Parda, D.3    Trombetta, M.4    Gayou, O.5    Reitz, B.6    Miften, M.7
  • 11
    • 0036310911 scopus 로고    scopus 로고
    • 125I on silver wire as matrix for brachytherapy for the treatment of eye and prostate cancer
    • 125I on silver wire as matrix for brachytherapy for the treatment of eye and prostate cancer. Appl. Radiat. Isot. 57 (2002) 359-367
    • (2002) Appl. Radiat. Isot. , vol.57 , pp. 359-367
    • Mathew, C.1    Majali, M.A.2    Balakrishnan, S.A.3
  • 12
    • 0033559977 scopus 로고    scopus 로고
    • Iodine-125 brachytherapy in the treatment of colorectal adenocarcinoma metastatic to the lever
    • Monge M.R., Nag S., Nieroda C., and Martin E.W. Iodine-125 brachytherapy in the treatment of colorectal adenocarcinoma metastatic to the lever. Cancer 85 6 (1999) 1218-1225
    • (1999) Cancer , vol.85 , Issue.6 , pp. 1218-1225
    • Monge, M.R.1    Nag, S.2    Nieroda, C.3    Martin, E.W.4
  • 13
    • 34748860292 scopus 로고    scopus 로고
    • Silver fluorescent X-ray yield and its influence on the dose rate constant for nine low-energy brachytherapy source models
    • Nath R., and Chen Z.J. Silver fluorescent X-ray yield and its influence on the dose rate constant for nine low-energy brachytherapy source models. Med. Phys. 34 10 (2007) 3785-3793
    • (2007) Med. Phys. , vol.34 , Issue.10 , pp. 3785-3793
    • Nath, R.1    Chen, Z.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.