메뉴 건너뛰기




Volumn 64, Issue 4, 2006, Pages 441-447

Studies on the production and quality assurance of miniature 125I radioactive sources suitable for treatment of ocular and prostate cancers

Author keywords

125I; Adsorption; Brachytherapy; Retinoblastoma

Indexed keywords

ADSORPTION; OPTIMIZATION; PARAMETER ESTIMATION; QUALITY ASSURANCE; RADIOACTIVE MATERIALS; TUMORS;

EID: 32044444844     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2005.08.011     Document Type: Article
Times cited : (27)

References (13)
  • 1
    • 32044448650 scopus 로고    scopus 로고
    • AERB SS-3 (Rev-1), A publication of Atomic Energy Regulatory Board of India.
    • AERB SS-3 (Rev-1), 2001. Testing and Classification of Sealed Radioactive Sources. A publication of Atomic Energy Regulatory Board of India.
    • (2001) Testing and Classification of Sealed Radioactive Sources
  • 3
    • 0035051575 scopus 로고    scopus 로고
    • Comparison of I-125 sources used for permanent interstitial implants
    • H.H.. Bret, E.W. Robert, and M.H. James Comparison of I-125 sources used for permanent interstitial implants Med. Phys. 28 2001 671 682
    • (2001) Med. Phys. , vol.28 , pp. 671-682
    • Bret, H.H.1    Robert, E.W.2    James, M.H.3
  • 4
    • 0030723711 scopus 로고    scopus 로고
    • Radiation therapy for choroidal melanoma
    • P.T. Finger Radiation therapy for choroidal melanoma Surv. Opthalmol. 42 1997 215 232
    • (1997) Surv. Opthalmol. , vol.42 , pp. 215-232
    • Finger, P.T.1
  • 8
    • 0036310911 scopus 로고    scopus 로고
    • 125I on silver wire as matrix for brachytherapy for the treatment of eye and prostate cancer
    • 125I on silver wire as matrix for brachytherapy for the treatment of eye and prostate cancer Appl. Radiat. Isot. 57 2002 359 367
    • (2002) Appl. Radiat. Isot. , vol.57 , pp. 359-367
    • Mathew, C.1    Majali, M.A.2    Balakrishnan, S.A.3
  • 9
    • 0033744896 scopus 로고    scopus 로고
    • Well- ionization chamber response relative to NIST air kerma strength standard for prostate brachytherapy seed
    • M.G. Mitch, B.E. Zimmerman, P. Lampbert, S.M. Seltzer, and B.M. Coursey Well- ionization chamber response relative to NIST air kerma strength standard for prostate brachytherapy seed Med. Phys 27 2000 2293 2296
    • (2000) Med. Phys , vol.27 , pp. 2293-2296
    • Mitch, M.G.1    Zimmerman, B.E.2    Lampbert, P.3    Seltzer, S.M.4    Coursey, B.M.5
  • 11
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation therapy committee Task Group No.-43
    • N. Ravinder, L.A. Lowell, L. Gary, A.W. Keith, F.W. Jeffery, and A.S. Meigooni Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation therapy committee Task Group No.-43 Med. Phys 22 1995 209 234
    • (1995) Med. Phys , vol.22 , pp. 209-234
    • Ravinder, N.1    Lowell, L.A.2    Gary, L.3    Keith, A.W.4    Jeffery, F.W.5    Meigooni, A.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.